(mm) 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Weight(kg) 3.15 3.35 3.55 3.75 3.95 4.15 4.35 4.55 4.75 4.95 5.15 5.35 5.55 5.75 5.95 6.15 6.35 6.55 6.75 6.95 0.53 Additional weight for lock(kg) 4 Model LEFS40 Stroke(mm) 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 Weight(kg) 5.37 5.65 5.93 6.21 6.49 6.77 7.15 7.33
*Refer to the table of Applicable stroke 6mm 6mm 8mm 8mm 10mm 10mm B B Cable type *Applicable stroke Standard produced upon receipt of order Without cable Nil Without cable Nil 100 100 200 200 300 300 400 400 500 500 600 600 700 700 800 800 900 900 1000 1000 Robotic type cable R Robotic type cable R 11-LEFS25 11-LEFS25 Standard cable S Standard cable S 11-LEFS32 11-LEFS32 Motor cable
[Tips] The TIME-OUT period is factory-configured to 300 seconds. The setting range is displayed on the Ten-key screen with the touch of the [SET] key. 5.3 Operation Screen HRZD Series 5-52 HRX-OM-M005 Chapter 5 Product Operation In the event of an error The ERROR window shown below is displayed when an error occurs that results in the termination of ongoing circulating fluid recovery.
User set values (PLC) Settable value by PLC (Offset Binary Expected value Range Signed Magnitude 2s Complement) 0..10 V 0 to 1050 0.00 to +10.50 V 0..5 V 0 to 525 0.00 to +5.25 V 1..5 V 75 to 525 +0.75 to +5.25 V 0..20 mA 0 to 2100 0.00 to +21.00 mA 4..20 mA 300 to 2100 +3.00 to +21.00 mA : If the data format is scaled data format, set the data as follows, regardless of the range setting.
H 5 Initial power/ Power consumption (W) 100 VAC 800/180 1200/300 1600/400 200 VAC 3200/180 4800/300 6400/400 Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for the size 16 models. 200V The heaters are PTC thermistor type design.
4000 Current (% to the capacity of the main breaker of this product) Figure 3-6 Breaker operating characteristics curve HRZ Series 3.3 Procedure for Installation 3-9 HRX-OM-I051 Chapter 3 Transporting and Installation HRZ008-L HRZ008-L1 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX 2min 1min Operating time 30s 20s 10s 5s 2s MIN 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500
(PAT.PEND) MHF MHL Over length L (mm) Gripping moment Weight (g) Bore size (mm) Model MHR (Nm) L MHK Over length L(mm) MHY2-10D 10 0.16 70 Gripping moment 71 Weight (g) Bore size (mm) Model (Nm) MHY2-16D 16 150 0.54 84 MHS L MHY2-20D 20 320 1.10 106 MHW2-20D 68 300 20 0.30 MHY2-25D 25 560 2.28 131 MHC MHW2-25D 510 25 0.73 78 At the pressure of 0.5 MPa 905 MHW2-32D 32 93.5 1.61 MHT Auto
MPa 0.5 MPa 0.6 MPa 0.5 MPa MHW 150 0.4 MPa 0.4 MPa 10 0.4 MPa 0.3 MPa 0.2 MPa 0.4 MPa 0.3 MPa 0.3 MPa 0.3 MPa MRHQ 100 L 0.2 MPa 0.2 MPa 0.2 MPa 5 Misc. 50 D0 10 20 30 40 50 0 50 100 150 Gripping point L (mm) Gripping point L (mm) 20MHZ2-16D/MHZL2-16D MHZ2-40D 400 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa 50 350 0.6 MPa 0.6 MPa 0.6 MPa 0.6 MPa Gripping force (N) 300
Built-in magnet for auto-switches CV MVGQ Maximum Driving Speed of Cylinders 1000 1000 900 900 Cylinder speed (mm/s) Cylinder speed (mm/s) 800 800 Load factor: 10% Load factor: 50% 700 700 600 600 500 500 400 400 300 300 200 200 100 100 0 12 16 20 25 32 40 50 63 80 100 0 SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) Series Variations Bore size (mm) Standard stroke (mm) Applicable valve series
MXH MXH Vertical Horizontal MXS L1: Load eccentricity MXQ m Mounting orientation m MXQ L H MXF L H MXW Maximum speed (mm/s) Up to 100 Up to 300 x Up to 500 Up to 100 100 b 50 v 200 n 50 m Up to 300 100 , 200 .
Delivery pressure (psig) 1.0 (25.4) 0.21 30 5 0.17 25 0.14 20 A Connections (mm) inch FV4 MV4 TW4 FV6 MV6 TW6 0.10 15 (70.6) 2.78 0.07 10 2.12 (53.8) 0.03 5 3.86 (98.0) 0.00 0 0 5 10 15 20 25 30 35 40 45 50 Flow rate (slpm, N2) 2.65 (67.3) SL5201A High flow option Inlet pressure: 2 psig (14 kPa) Standard 760 0 700 -8 Delivery pressure (Hg abs) 600 -21 Delivery pressure (kPa) 500 -35 400 -48 300
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MHY2-10D 10 0.16 70 Gripping moment 71 Weight (g) Bore size (mm) Model (Nm) MHY2-16D 16 150 0.54 84 MHS L MHY2-20D 20 320 1.10 106 MHW2-20D 300 68 20 0.30 MHY2-25D 25 560 2.28 131 MHC MHW2-25D 510 25 0.73 78 At the pressure of 0.5 MPa 905 MHW2-32D 32
MPa 0.5 MPa F 80 6 0.3 MPa 0.3 MPa 0.4 MPa 0.4 MPa 0.3 MPa 0.2 MPa 60 0.2 MPa 0.2 MPa 0.3 MPa 4 40 0.2 MPa 2 20 0 20 40 60 80 100 10 20 30 0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F Gripping point L (mm) Gripping point L (mm) MHZ2-10D/MHZL2-10D MHZ2-32D 300
400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310-01 ARJF310F
Maintenance Caution Model Connection (Flange) 2B 8B C 2B/3B/4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 X l 400 Anchor bolt M20 X l 500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 q It is not possible to indicate a definite replacement interval for the element because it varies with the odor concentration of the compressed air.
100 300 500 300 500 700 1000 2000 2500 3000 4000 4000-06 5000 6000 1000 2000 3000 4000 4000-06 2550 3050 4050 4050-06 3050 4050 4050-06 2060 2560 3060 4060 4060-06 5060 6060 425 625 825 925 3000 210 1020 300 400 500 600 AWM Mist separator regulator VQZ AWD Micro mist separator regulator SQ AS Speed controller VQD SY Flow control valves SYJ SX 3-port solenoid valve (2) VQ VQ VQZ AS Speed
timer Grommet 3 wire(NPN) IC 5V, 12V G59F With diagnostic output (2 color) 4 wire(NPN) Latch with dianostic output (2 color) H7LF *Lead wire length 0.5m (Example) B80C 5m Z (Example) B80CZ 3m Z (Example) B80CL N (Example) B80CN * : Manufactured upon receipt of order Stroke Long stroke (mm) Standard stroke (mm) Model Bearing Bore size (mm) 20 25 32 40 50 75, 100, 125, 150, 200 250, 300
(PAT.PEND) Over length Lmm Holding mement Weight g Bore size mm Model Nm L 300 20 0.30 MHW2-20D 68 510 25 MHW2-25D 0.73 78 905 32 MHW2-32D 1.61 93.5 2135 40 MHW2-40D 3.70 117.5 5100 50 MHW2-50D 8.27 154 At the pressure of 0.5MPa Auto switch mounting at 4 locations MHZ2 MHZJ2 Two finger styles available.
VS Surge voltage suppressor mounting part VFN Surge voltage suppressor Electrical entry JIS Symbol G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire D DIN terminal E Grommet terminal T Conduit terminal Manifold Applicable manifold type Accessory Function plate (DXT152-14-1A) Note) Mounting screw (NXT013-3) Model VO307 Common or individual exhaust Note) It is not applied to Continuous
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VQC2000 800 700 600 500 400 300 200 100 0 VQC4000 Values at extension of a directly coupled cylinder when meter-out speed controllers are used with the needle full open.