K J E Size variations Standard strokes Model Auto switch 20 30 40 50 100 60 70 80 90 C(D)U20 20 to 32 Direct mounting type auto switch C(D)U25 C(D)U32 Features 2 Free-Mounting Cylinder with Air Cushion Series CU 20, 25, 32 How to Order CU 32 32 50 50 A A F9BW With auto switch CDU Without auto switch Number of auto switches With auto switch (built-in magnet) 2 pcs. Nil S 1 pc.
Series 10 12 16 20 25 32 40 50 63 80 100 MGP 3.5 5.0 4.5 4.5 5.5 5.5 5.5 5.5 5.5 6.0 MGZ 5.5 6.5 6.5 CA2 4.0 4.0 6.0 6.0 6.0 Sensor unit: D-F7K Air cylinder Unit: mm Tube I.D.
D Constant Setting range : 0.0 to 99.9sec Min. increment : 0.1sec Indicated content : D constant(Ex. : 0.0sec) D C o n s t a n t M O D E < 0 . 0 s e c Function : Sets differential time used for PID control. When 0 is set, this function becomes invalid. 7.
(3) Dustproof (Degrees of protection 0) (4) 100, 200 VAC, 50/60 Hz; 24 VDC 15 to +10% of rated voltage Class E or equivalent (120C) (5) 4.5 VA/50 Hz, 4.2 VA/60 Hz 3.5 VA/50 Hz, 3 VA/60 Hz 1.8 W Plug-in type (FZ) Non plug-in type Grommet (G), Plug connector (L, M, KZ) DIN terminal (D) Inrush Holding Apparent power (AC) Power consumption (DC) Electrical entry Note 1) Use dry air at low temperatures
(3) Dustproof (Degrees of protection 0) (4) 100, 200 VAC, 50/60 Hz; 24 VDC 15 to +10% of rated voltage Class E or equivalent (120C) (5) Inrush Holding 4.5 VA/50 Hz, 4.2 VA/60 Hz 3.5 VA/50 Hz, 3 VA/60 Hz 1.8 W Plug-in type (FZ) Non plug-in type Grommet (G), Plug connector (L, M, KZ) DIN terminal (D) Apparent power (AC) Power consumption (DC) Electrical entry Note 1) Use dry air at low temperatures
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
Single flat Single flat D D D D D D D D C Single flat Single flat (mm) 15 9 18 20 10 20 30 13 22 40 15 30 10 8 14 Size C D Note ) Dimensions and tolerance of the shaft and single flat (a parallel keyway for size 40) are the same as the standard.
SV <5> D constant setting / Mode indicator: Initial value: 0 sec. Setting range 0 to 3600 sec. PV D constant (derivative time) setting Indicates that the D constant setting mode is activated with Indicator . Function Sets the derivative time used for PID control. If 0 is set, differentiation is not implemented.
MHZ MHF Hysteresis Switch operating position (ON) MHL Switch reset position (OFF) Auto switch Flat head watchmakers screwdriver MHR (mm) Auto switch model Air gripper model D-Y7W D-Y7WV D-Y59, D-Y7P D-Y69, D-Y7PV D-Y7BAL MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
M L 1/8" (3.18) 0.086" (2.18) KFG2L0122-00 8 1.1 8 7 13.3 5 1.5 H1 d 5/32" (4) 0.098" (2.5) KFG2L0325-00 8 1.6 8 7 13.3 5 2.3 H2 H2 M L 1/4" (6.35) 5/32" (3.95) KFG2L0704-00 12 6 18 10 16.5 6 3.3 5/16" (8) 0.236" (6) KFG2L0906-00 14 17 28 12 18.7 6.6 5.3 d 3/8" (9.53) 1/4" (6.35) KFG2L1163-00 17 19 50 15 22.2 7.6 5.6 1/2" (12.7) 3/8" (9.53) KFG2L1395-00 19 51 62 17 24.8 8.5 8.5 330 KFG2 Series
50/60 Hz 9 Other Option How to Order Pilot Valve Assembly External pilot 00 VT3113 G 1 Coil rated voltage Electrical entry 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz G Grommet Conduit terminal DIN terminal TL D T Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot. 4 Conduit terminal with indicator light TS Conduit
Digital flow switch Air combination Spacer Spacer with bracket Pipe adapter PF3A701H AC30#-D Y300-D Y300T-D E300-#03-D PF3A702H AC40#-D Y400-D Y400T-D E400-#04-D : For more information about the options, refer to our website (URL https://www.smcworld.com). -17No.PF-OMX0007-A
Foundation bolt L1 (mm) Nominal thread size d M16 L1 R Applicable model d1 S L Part No. (Approx.) (Approx.) FGF-OP05 Hexagon nut d FGF1-20 16 40 71 31.5 400 R d1 FGF3-40 AI-3S M20 20 50 90 40 500 FGF5-60 S Note) 3 foundation bolts are required per filter unit. If ordering only foundation bolts, order 3 bolts using the above part number.
16 18.5 M L 8 12 KPQL12-00 KPGL12-00 31.4 7.5 25 50 40 20 20.9 Note 1) D indicates the maximum diameter.
Meter-out M5 type U10/32 port AS3200-02-D Meter-out M5 type U10/32 port AS2210-01-D AS3210-02-D Component Parts No.
1 2 3 4 5 6 7 9 Coil rated voltage 1 2 3 4 5 6 7 9 Light/surge voltage suppressor Non-locking push type Non-locking extended type Locking slotted type 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other VC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Nil S Z None With surge voltage
Without auto switch (Without built-in magnet) Remarks Symbol Heater Temperature 16 D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Nil H0 H4 H5 5 to 60C None None With 100C heater With 120C heater Solid state auto switch 5 to 150C Reed auto switch (Not applicable to flange size 16) Note) Size 16 is not