A 1.18 (30) 1.61 (41) B 1.34 (34) 1.57 (40) C D E F G 136314 2.76 (70) 2.97 (75.5) .21 (5.4) .26 (6.5) .61 (15.4) .31 (8) 2.17 (55) 2.09 (53) .09 (2.3) .09 (2.3) NARM2500 43.5 136414 NARM3000 30 15 Precautions 0 35.3 70.6 106 Be sure to read before handling.

Replacement Parts Plug connector assembly (for plug lead) Sub-plate Lead wire length S07014A Port size S070S M3 M3 M5 M3 female thread M5 female thread 150 mm 300 mm 600 mm 1000 mm Nil 3 6 10 Gasket Mounting screw Valve model S070A S070B S070M Gasket No. S070A-80A-1 S070B-80A-1 S070M-80A-1 Valve model S070B S070C Mounting screw No.

Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 125mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: P (Air Pressure Lock-up)

Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)

Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 125mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 63mm, Thread: NPT, Stroke: 450mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40

Thus, from the formula on the front matter 9, the adsorption response time is as follows: T = (V x 60)/Q = (0.0031 x 60)/1.7 = 0.109 seconds = 109 msec It is possible to confirm that the calculation result satisfies the required specification of 300 msec. Front matter 15 Model Selection 8 Data #Selection Graph Selection Graph (2) Piping Capacity by Tube I.D.

2 m 4 m 6 m 13 m Filtration efficiency 99% FQ1 HEPO 2 FGH100 to 300 FN The membrane element cannot be selected for FGH100.

Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40

Set range is 0 to 300 sec. to Contact input signal 2 OFF detection timer Setting and checking 43. Press the [SEL] key once. The set screen of contact input signal 2 OFF detection timer is displayed on the digital display. PV SV 44. Select contact input signal 2 OFF detection timer from the table below with [] key or [] key, and confirm by pressing SEL.