Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 650, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 175mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 300mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 700mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 650, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40
Thus, from the formula on the front matter 9, the adsorption response time is as follows: T = (V x 60)/Q = (0.0031 x 60)/1.7 = 0.109 seconds = 109 msec It is possible to confirm that the calculation result satisfies the required specification of 300 msec. Front matter 15 Model Selection 8 Data #Selection Graph Selection Graph (2) Piping Capacity by Tube I.D.
2 m 4 m 6 m 13 m Filtration efficiency 99% FQ1 HEPO 2 FGH100 to 300 FN The membrane element cannot be selected for FGH100.
Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40
Set range is 0 to 300 sec. to Contact input signal 2 OFF detection timer Setting and checking 43. Press the [SEL] key once. The set screen of contact input signal 2 OFF detection timer is displayed on the digital display. PV SV 44. Select contact input signal 2 OFF detection timer from the table below with [] key or [] key, and confirm by pressing SEL.
(0.02 to 11.8in/s) 25 25, 50, 75, 100, 125, 150 200, 250, 300 Allowable kinetic energy J (ftlb) 0.27 (0.20) 0.4 (0.30) 0.65 (0.48) 1.2 (0.89) 32 40 Mounting Bracket Part Numbers Note 1) Intermediate strokes other than the above are produced upon receipt of order.
length 300 mm) MN: Without lead wire L: With lead wire (length 300 mm) G: Lead wire length 300 mm + + + + W: With connector cable Note 1) LN: Without lead wire LO: Without connector MO: Without connector H: Lead wire length 600 mm + + Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached.