or less Type R, U Type S, Z 19 or less 26 or less 2 position single 18 or less 18 or less 22 or less 2 position double 32 or less 32 or less 38 or less 3 position Type R, U Type S, Z 35 or less 41 or less 2 position single 35 or less 35 or less 41 or less 2 position double 62 or less 62 or less 64 or less 3 position 2 Body Ported Flow Characteristics/Weight Series SY3000 Series SY7000 Port
51 SYJ312 SYJ322 SYJ332 SYJ342 SYJ352 SYJ314 SYJ324 SYJ334 SYJ344 SYJ354 SYJ313 SYJ323 SYJ333 SYJ343 SYJ353 2 position 0.9 (0.05) 5 Port Body ported type M3 0.5 50 54 3 position 59(33) 73(47) 61(35) 77(51) 2 position 5 Port Base mounted type (With sub-plate) 1.8 (0.1) Body ported type M5 0.8 76(50) 80(54) 3 position 33 47 35 51 2 position 4 Port Base mounted type For manifold use only Note1
Note 5) Refer to page 35 for details when equipped with ejector unit. Also, "-J" and name plate "-N" cannot be combined. Note 6) Be sure to indicate wiring specifications in the specification table. Note 7) In case of an external pilot "R", indicate external pilot specification "R" for the applicable valve also.
across flats 16 15 D 3 3 F Width across flats 12 Width across flats 12 F Width across flats 10 Width across flats 2 Width across flats 3 3 C C 2 2 A A B B Dimensions A Dimensions A (mm) (mm) B C D F Y B C D F Model Model ZPT10F-B5-A8 ZPT20F-B5-A10 10 12 10 12.5 37.5 20 22 1.5 12.5 15.5 48.5 ZPT13F-B5-A8 ZPT25F-B5-A10 13 15 25 28 10.5 13 38 ZPT16F-B5-A8 ZPT32F-B5-A10 2 13 16 49 16 18 32 35
External Connections (P.20) 7.6 Parallel I/O Connector wiring (example) (P.35) Check that the wiring is correct. Refer to the wiring instructions in the controller operation manual and check the wiring for broken wires and shortcircuits. Incorrect wiring Check if the controller has generated an alarm? Check the type of alarm.
ZQ-OM01401-B / / ZQA No.ZQ-OM01401-B 2 1. 5 2. 9 3. 11 3.1. 11 3.2. 12 3.3. 13 3.4. 14 3.5. 16 4. 17 5. 19 6. 20 7. 21 8. 28 9. 32 10. 35 11. 37 12. 40 13. 42 1 - No.ZQ-OM01401-B /ZQA *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery
Pressure characteristics 5% F.S. 1 digit (0.35 MPa standard) Pressure Power supply voltage*4 For the switch output device 12 to 24 VDC 10% For the IO-Link device 18 to 30 VDC 10% Current consumption 35 mA or less Protection Polarity protection Electrical Display accuracy 3% F.S. 1 digit Analog output accuracy 3% F.S.
-01 2 position double: SYJA7240VTA 2 x 4.3 (For mounting) 34 8.5 63.6 2 x M5 x 0.8 (Pilot port) 2 x M5 x 0.8 (Pilot port) VGA B A 1 1 13 3 VPA B A 34 27 B A 1 1 1/8 (A, B port) 2 x 3.2 (For manifold mounting) 17 R1 R2 P VPA3 35 31.5 63.6 35 2 x 3.2 (For mounting) Manual override 74.6 Manual override 1/8,1/4 (P , A, B port) 28 25 21 14 74.6 54 1/8 (P , R1, R2 port) 40 2 x 1.8 (Bleed port)
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.
P Q R S 4 4 20.6 15.6 10.4 6 6 21.6 16.6 12.8 F L AT T Y P E F L AT W I T H R I B Y Model A B C D E F G H I Flat Flat with Rib ZPR20 20 23 14 29 39.8 57.6 68.6 91.5 102.6 4 1.7 ZPR25 25 28 14 29 39.8 57.6 68.6 91.5 102.6 4 1.8 ZPR32 32 35 14.5 29.5 40.3 58.1 69.1 92 103.1 4.5 23 D E E P T Y P E Model A B C D E F G H I Y ZPR25D 25 28 20 35 45.8 63.6 74.6 97.6 108.6 10 A P P L I C A B L E T
Specifications Switch rail CY1L Applicable Series Bore size 6 to 40 Bore size (mm) Applicable stroke (mm) 6 10 15 20 25 32 40 20 to 25 to 35 to CY3B CY3R CY1S CY1L CY1L CY1H CY1H CY1F CYP D-X Technical Data 1539
) 36 35 31 25 (17.5) 16.5 (45) 26.2 15 (20.9) (Distance between ports) 2.8 (54.5) 1/8, 1/4 1(P), 3(R) port 4.5 1P 26.5 NO 3 3R M5 x 0.8 (Breathing hole) 16 20.4 53.7 01 02 A B For vacuum/VPA342V-1(-F) 1/8, 1/4 2(A) port 26.2 2 x 3.2 (For mounting) 21.5 NC 2A 3.4 (1.6) 20.4 16 65.2 (9) 2 x 3.2 (For mounting) 1/8 12(PA) port (Mounting groove for M5 thread) (5.4) 12 (35) 36 35 31 25 16.5 (17.5
60 38 160 88 185 140 15 166 18 21 J VF3000 100 84 66 30 112 40 224 55.5 56.5 62 M14 x 2 35 M14 x 2 M14 x 2 41 44 80 190 108 221 170 15 200 21 25 Note 1) It is possible to manufacture the intermediate strokes other than the standard strokes by means of installing a spacer.
D L1 VMG KN KN 861 KN Series Nozzle for One-touch fitting/KN (mm) Model Nozzle size D Applicable fitting size d L1 A Weight (g) KN-Q06-100 KN-Q06-150 KN-Q06-200 KN-Q08-150 KN-Q08-200 KN-Q10-200 KN-Q10-250 KN-Q12-250 KN-Q12-300 5 5 5 9 9 16 16 23 23 18 18 18 20.5 20.5 22 22 24 24 35 35 35 39 39 43 43 45.5 45.5 6 6 6 8 8 10 10 12 12 1 1.5 2 1.5 2 2 2.5 2.5 3 D 10 A Connecting products with
CN5I/O . 23 6.1 . 23 6.2 (NPNPNP ) . 23 (1) I/O (NPNPNP ) . 23 (2) I/O . 23 6.3 . 24 6.4 I/O . 27 7. . 28 7.1 . 28 7.2 . 31 7.3 . 33 8. . 34 8.1 . 34 8.2 . 34 8.3 . 35 (1) . 35 (2) (). 35 (3) . 35 8.4 . 36 8.5 . 36 9. (). 37 9.1 . 37 9.2 . 38 10. . 39 10.1 . 39 10.2 I/O . 39 (1) . 39 (2) . 40 (3) . 41 (4) HOLD. 42 (5) . 42 2 - 6 . 42 (7) . 43 11. . 44 11.1 . 44 11.2 (). 45 11.3 I/O . 46 11.4
(For D-Y) 4 Finger Position/Narrow Type 9 MHZ2-20N 14 Auto switch mounting groove (For D-F, D-M9(V)) 2.1 +2.2 0 0 0.4 When open 17.2 When closed 7.2 Note) When using D-Y59, D-Y69 and D-Y7 type auto switches, through-hole mounting is not possible. 12-2-35 35 Series MHZ2 Dimensions MHZ2-25 Double acting/Single acting Basic type 36.5 22 2-M6 x 1 thread depth 10 (Mounting thread) 4-M6 x 1 thread
Therefore, never connect it to other equipment as this may cause fire or malfunction. 86 15 Regenerative Absorption Unit Series LC7R Dimensions 52 97 35 38 96 Operation window Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 35 Label DIN rail holding plate 22 22 Connector
(For D-Y) 4 Finger Position/Narrow Type 9 MHZ2-20N 14 Auto switch mounting groove (For D-F, D-M9(V)) 2.1 +2.2 0 0 0.4 When open 17.2 When closed 7.2 Note) When using D-Y59, D-Y69 and D-Y7 type auto switches, through-hole mounting is not possible. 12-2-35 35 Series MHZ2 Dimensions MHZ2-25 Double acting/Single acting Basic type 36.5 22 2-M6 x 1 thread depth 10 (Mounting thread) 4-M6 x 1 thread
Bracket (Mounting hole) 23.2 (PA port) Rc 1/8 (Mounting groove for M5 thread) 2-R2.7 PA 5 36 35 35 3.5 21.5 31 17.5 1.6 15 26.7 45 9 54.5 65.6 54.4 1(P) 3(R) 4.5 (Piping port) Rc 1/4,1/8 (Breathing port) M5 x 0.8 16.5 20.4 5-5-15 4 Series VPA300/500/700 Dimensions Base mounted: VPA344A B (A port) Rc 1/8,1/4 12 65.6 58.6 39 12 30 (PA port) Rc 1/8 (PA port) Rc 1/8 2(A) NO 26.5 35 43 PA PA
Bracket (Mounting hole) 23.2 (PA port) Rc 1/8 (Mounting groove for M5 thread) 2-R2.7 PA 5 36 35 35 3.5 21.5 31 17.5 1.6 15 26.7 45 9 54.5 65.6 54.4 1(P) 3(R) 4.5 (Piping port) Rc 1/4,1/8 (Breathing port) M5 x 0.8 16.5 20.4 5-5-15 4 Series VPA300/500/700 Dimensions Base mounted: VPA344A B (A port) Rc 1/8,1/4 12 65.6 58.6 39 12 30 (PA port) Rc 1/8 (PA port) Rc 1/8 2(A) NO 26.5 35 43 PA PA