C37 Series 200 Symbol Port size PB 300 SUS M5 01 02 M5 1/8 (6A) 1/4 (8A) Thread type Nil F N Rc G NPT Piping to 3 Port Valve N.O. Port Caution Socket Electricity 1. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. Cover Others 1. Material NBR: Nitrile rubber FKM: Fluoro rubber = FPM Trade names: Viton, Dai-El, etc.
Number SS070A 01 1A O-ring FKM 10 SS070A-80A-1 Port size Clip Stainless steel 10 SS070A-80A-2 With 3.18/2 barb fitting With 4/2.5 barb fitting 01 02 Metal joint Stainless steel 10 SS070A-80A-3 Leaf spring Stainless steel 10 SS070A-80A-4 Mounting bracket Stainless steel 10 SS070A-80A-5 < U Side End Plate Assembly > 2 U side end plate assembly No.
Specifications Max. operating pressure Min. operating pressure
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE AIR SAVER, AIRLINE EQUIPMENT, ASR METERED QUICK EXHAUST, 2B, ASR NO SIZE RASTANDARD (PT), .35287 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE AIR SAVER, AIRLINE EQUIPMENT, ASR METERED QUICK EXHAUST, 1B, ASR OTHER SIZESTANDARD (PT), .35287 lb
Series ASP is a speed controller with an integrated pilot check valve. This combination makes it possible to control cylinder speeds and permits temporary intermediate stops. The ASP is standard with electroless nickel plating on all brass parts and allows 360 degree freedom for tube mounting direction.Pilot check operates with 50% of operating pressure, One-touch connection for supply air
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FLOW CONTROL DUAL SPEED S/S, AIRLINE EQUIPMENT, ASD DUAL SPEED CONTROLLER, EB, ASD 3/8INCH STANDARD (PT), 0.19649 lb
Series ASP is a speed controller with an integrated pilot check valve. This combination makes it possible to control cylinder speeds and permits temporary intermediate stops. The ASP is standard with electroless nickel plating on all brass parts and allows 360 degree freedom for tube mounting direction.Pilot check operates with 50% of operating pressure, One-touch connection for supply air
Suitable for applications where copper free specifications are required, the in.?FGin. series can also be used in areas where wash down could degrade standard flow controls, such as food and packaging. This series is designed to offer the maximum control by increasing the number of turns of the needle to 10. The body and adjustment are made of high impact white resin for a clean look. This
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SPEED CONTROL W/FITTING, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, DB, AS***F 1/4INCHSTANDARD (PT), .08106 lb
Series ASD, combines a meter-in and meter-out dual speed controller in a single body. The series is available with PT or NPT ports and one-touch fittings are standard. Tamper proof and flat head screwdriver adjustable versions are also available for extra protection against inadvertent operation.Dual speed controller with one-touch fitting, Enables bi-directional flow control, Unrestricted
Series ASP is a speed controller with an integrated pilot check valve. This combination makes it possible to control cylinder speeds and permits temporary intermediate stops. The ASP is standard with electroless nickel plating on all brass parts and allows 360 degree freedom for tube mounting direction.Pilot check operates with 50% of operating pressure, One-touch connection for supply air
Metric sizes Type 04 06 08 10 12 4 6 8 10 12 2 Elbow Control type 0 1 Meter-out Meter-in Port size M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 With One-touch fitting Clean specifications Metal parts material Q G Brass (electoless nickel plated) Stainless steel 304 Needle Valve/Flow Characteristics AS121FP-M5 AS221FP-01 AS221FP-02 08,10 06,08 06 04 04 AS321FP-03 AS421FP-04 12 10 10,12 08 06 15
BA-32 BA-04 c BD1-01M BD1-02M BD1-02 BD1-04M Auto switch mounting band Note 1) Set part number which includes the auto switch mounting band (BMA2-A) and the holder kit (BJ5-1/Switch bracket: Transparent).
Size 26 mm Size 18 mm CE compliant Nil Q CE compliant Stations 1 1 station Option Nil None 16 16 stations Special wiring specifications (Except double wiring) K Cylinder port size Direct exhaust with built-in silencer S Symbol 01 02 03 01B 02B Port size Side ported 1/8" Side ported 1/4" Side ported 3/8" Bottom ported 1/8" Bottom ported 1/4" Size 26 mm Size 18 mm R M Note) External pilot
(Refer to p.4.9-5) Caution Model Recommended SMC speed controller Caution Model Elbow Straight In-line REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC32 AS3201F-01-08-X214 AS3001F-08-X214 AS3201F-01-08-X214 REC40 AS3201F-02-08-X214 AS3001F-08-X214 AS3301F-02-08-X214 4.9-3 Be sure to read before handling.
M L2 Pressure range Option 3 Symbol Description ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with
VAC 100 VN SY100-82-2-01 200 VAC 200 VN SY100-82-2-02 110 VAC (115 VAC) 110 VN SY100-82-2-03 220 VAC (230 VAC) 220 VN SY100-82-2-04 When making connections, please note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
to left Option Body size Port size Symbol Nil Description Applicable model 40 50 60 80 90 2 1 02 03 04 06 10 12 14 20 4 1 4 3 B 8 3 With bracket ALF400 to 600 1 1 2 2 1 Metal case with a level gauge X208 ALF400 to 900 2 1 4 3 1 1 1 2 4 1 Line pressure (MPa) 2 1 Note 1) Tank pressure is removed when line pressure is stopped.