AREA A position 2 The AREA signal is output commonly for the ranges set for both the AREA A and AREA B. AREA B Set as AREA 1 AREA 2. position 1 AREA B position 2 48 - Data (Saved data) Data is sent as hexadecimal numbers.

A96 A96V 5 V IC circuit Yes Reed switch A72 A72H 12 V 200 V 100 V Grommet A93 A90 A93V A90V No IC circuit 5 V,12 V 12 V Relay, PLC 100 V or less 2-wire 24 V A73C A80C A79W Yes No Connector IC circuit 5 V,12 V 24 V or less Yes Grommet With diagnostic output (2-color indication) Solid state auto switches marked with a "" are produced upon receipt of order.

Power supply Single phase 200VAC (A type) or Single phase 100VAC (A1 type) MC NFB Servomotor HC-PQ C P U V W L1 U V Servo amp MR-CA or SM L2 E W MR-CA1 The cable length between the controller and servo amp is 2m or less. 24VDC Z CN1 EMG Note 7) Shuts off with alarm signal when servo ON is turned OFF.

Nil M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 TF G 1/8 G 1/8 G 1/8 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 b C H B d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 H 4 8 8 10 B 14 26 32 41 C 16.2 30 37 47.3 Part No.

Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet 0.44 0.40 0.40 0.44 0.40 0.41 0.63 0.63 0.41 0.63 0.13 0.10 0.10 0.13 0.10 0.20 0.14 0.14 0.20 0.14 VK332 0.47 0.41 0.41 0.47 0.41 0.85 0.65 0.65 0.85 0.65 0.47 0.38 0.38 0.47 0.38 0.76 0.41 0.41 0.76 0.41 0.44 0.27 0.27 0.44 0.27 0.26 0.24 0.24 0.26 0.24 0.13 0.10 0.10 0.13 0.10 0.19 0.15 0.15 0.19 0.15 0.47 0.39 0.39

SMC PRESSURE SWITCH PD PV 57 1 67 1 32.4 109 Approx. 300 Ejector RESET SET Supply valve Release valve V 21.2 Manual override Suction filter 1 2-4.6 (mounting hole) 1 5.6 1 8 1 10.2 123 1 4.6 1 8 SOL. c SOL. a Silencer SOL. b Interface A Light Suction filter Manual override Interface B Digital vacuum pressure switch M5 port PE (pilot valve exhaust port) M5 port PD (vacuum breaking pressure

( , 0( , = ) % $ B /EB3A /EB '!' B /EBA /EB '' B /EBA /EB '' B /EB3A /EB '' i D 3 B /EB A /EB '4' % *% o ?%) , < Series VKF300 $ "# $ %& ! %& ! ! "# $ %& ' ( &) $%% / / 01 * & * * & ) # ! %& !+ & ,,& &-% + &) ,.. ! "# ! * & ) $%% / / 01 * & * ' ( &) !+ & ,,& &-% + &) ,.. ! " # $ # ! %& Series VKF300 * ( / 73 * "" ()*+ "" ,&30 ! // 44 44 $ %& ' !"

(IEC 60417-5032-1) How to see the serial number A R 001 APR 2022 Z R 001 Year Symbol Remarks Month Symbol Remarks Serial no. 1 o Repeated from O to Z in alphabetical order, with O for January and Z for December 2022 A Repeated from A to Z in alphabetical order 2023 B 2 P 2024 C 3 Q Fig. 1-1 Position of the product label HRS Series 1.4 Product Label 1-3 DOC1001322 Chapter 1 Safety Instructions

Insulation type Electrical entry Electrical option Class B G C D, T S Note) S L, Z 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) AC DC Note) Surge voltage suppressor is attached in the middle of a lead wire. 17-3-72 3 The VX series will be revised shortly.

External switch signal Current consumption: 5 mA or less Max. load current: 40 mA Max. load current: 40 mA Discharge signal Residual voltage: 1 V or less Residual voltage: 1 V or less Error signal Output signal (with load current of 40 mA) (with load current of 40 mA) Max. applied voltage: DC 28 V Maintenance signal Effective charge eliminating distance 20~500 mm 0~55oC Ambient temp.

(NPN equivalent) 100 V 12 V Relay, PLC 2-wire 24 V A90V No IC circuit 5 V,12 V 100 V or less 1Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

ARP30(K) ARP40(K) H J H J H J M N Q R S T U V W Y l28 l27.8 37.5 29.5 40 66 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 l28 l27.8 37.5 30.5 41 67 41 40 44 6.5 8 53 2.3 31 38.5 19 7 l28 l27.8 42.5 35 45 74 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 Note 1) The total length of B direction is the length when the filter regulator knob is unlocked.

Panel mount Model Z ARP20(K) H J H J M N Q R S T U V W Y 27.8 1021 1021 1021 44 40 69 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 ARP30(K) 27.8 44 41 70 41 40 44 6.5 8 53 2.3 31 38.5 19 7 ARP40(K) 27.8 44 45 74 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 Note 1) The total length of B direction is the length when the filter regulator knob is unlocked.

ARP30(K) ARP40(K) H J H J H J M N Q R S T U V W Y l28 l27.8 37.5 29.5 40 66 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 l28 l27.8 37.5 30.5 41 67 41 40 44 6.5 8 53 2.3 31 38.5 19 7 l28 l27.8 42.5 35 45 74 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 Note 1) The total length of B direction is the length when the filter regulator knob is unlocked.

Panel mount Model Z ARP20(K) H J H J M N Q R S T U V W Y 27.8 1021 1021 1021 44 40 69 30 34 47 5.4 15.4 55 2.3 28 28.5 14 6 ARP30(K) 27.8 44 41 70 41 40 44 6.5 8 53 2.3 31 38.5 19 7 ARP40(K) 27.8 44 45 74 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 Note 1) The total length of B direction is the length when the filter regulator knob is unlocked.

Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Since there are other

(same side) D-Y59A (B), Y69A (B) Y7P (V) 20 1 pc., 2 pcs. (different sides) 70 2 pcs. (same side) D-Y7NW (V), Y7PW (V) Solid state switch Y7BW (V) 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.

VC 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 SY100-82-2-02 SY100-82-2-03 24 V 12 V 100 V 200 V 110 V A VDW A VQ B DIN Terminal Circuit with Indicator Light VX2 A AC circuit DC circuit Mounting procedure 1) Hook the mounting hook on the side of the manifold base to the DIN rail. 2) Lift the side of the manifold off the DIN rail and slide it in the