Valve Mounting Direction: Single Solenoid Coil on the Same Side as A,B Ports, Piping: 5 Port/Base Mounted Common SUP Common EXH, Stations: 10 Stations, A B Port Size: ø4 One-touch Fitting, P R Port Thread: -

Valve Mounting Direction: Single Solenoid Coil on the Same Side as A,B Ports, Piping: 5 Port/Base Mounted Common SUP Common EXH, Stations: 10 Stations, A B Port Size: ø4 One-touch Fitting, P R Port Thread: G

Valve Mounting Direction: Single Solenoid Coil on the Same Side as A,B Ports, Piping: 5 Port/Base Mounted Common SUP Common EXH, Stations: 10 Stations, A B Port Size: Base Mounted M5X0.8, P R Port Thread: G

Valve Mounting Direction: Single Solenoid Coil on the Same Side as A,B Ports, Piping: 5 Port/Base Mounted Common SUP Common EXH, Stations: 10 Stations, A B Port Size: 5/32" One-touch Fitting NPTF, P R Port Thread: -

The SY is available in body ported or base mounted styles and can be used individually or manifold mounted., MANIFOLD ASSY, 10-STA, VALVE, SS3Y1 MANIFOLD SY100, 15, SS3Y1 OTHER SIZE RATING, .18521 lb

14 10 14 12 16 20 24 27 38 41 51 37 41 50 41 45 57 42 43 53 72 78 KA 4 2.5 1.8 1.6 10 8 13.5 5 4 3 KQG2 2.3 2.6 Applicable tubing L1 M 6 4 6 10 10 15 5.8 3.3 KG H1 12 d 8 6 KFG2 KFG2 5.3 12 14 17.4 6.6 16 22.2 A L2 23 H2 MS 25.6 10 7.5 6.8 26 Connection thread 27.5 15 17 20.9 7.6 KKA 27 25.6 10 8 7.3 30 KP 27.5 27 25.6 12 9 8 LQ 35 27.5 16 17 23.5 8.5 34 MQR 25.6 12 10 9 44 27.5 31 32.9

Specific heat C [kg/m 3] [g/L] ([kcal/kgC]) [J/(kgK)] 10C 1.10 x 10 3 3.02 x 10 3 0.72 20C 1.08 x 10 3 3.15 x 10 3 0.75 50C 1.06 x 10 3 3.27 x 10 3 0.78 80C 1.04 x 10 3 3.40 x 10 3 0.81 Water Density : 1 x 10 3 [kg/m 3] [g/L] Specific heat C: 4.2 x 10 3 [J/(kgK)] (1.0 [kcal/kgC]) 107 Thermo-chiller Series HRW Fluorinated Fluid Type SEMI How to Order 002 H HRW Fluorinated FluidType Option

Grinding fluid (Grinding machines) Fiber element Polypropylene 10 Grinding fluid (Oilstone) Fiber element Polypropylene 10 Lubricating oil Fiber element Polypropylene 50 Cooling water Fiber element Polypropylene 10 Cleaning water Fiber element Polypropylene 10 Developing fluid Fiber element Cotton 50 Lacquer Fiber element Cotton 10 Nitrogen gas Fiber element Cotton 10 Carbon dioxide Fiber

Normal output Reversed output -100No.PF-OMA1011-A Specifications Model PFG20# series PF2A5 PF3W5 PF2D5 Applicable flow sensor 10 50 11 21 51 04 20 40 11 25 04 20 40 Rated flow range 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 0.4 to 4 1.8 to 20 4 to 40 L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min L/min 0.35 to 1.7 to

to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 13 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.

method Heating type sensor (branch flow type) Rated flow range 10 to 1000 L/min 20 to 2000 L/min Instantaneous flow 10 to 1050 L/min 20 to 2100 L/min Set point range Accumulated flow 0 to 999,999,999,990 L Flow specifications Instantaneous flow 1 L/min 2 L/min Minimum resolution Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.)

Body size Part no. 4 6 8 10 6 8 10 12 12 16 4 6 8 10 6 8 10 12 12 16 KK3P-04L -06L -08L -10L KK4P-06L -08L -10L -12L KK6P-12L -16L KK3S-04L -06L -08L -10L KK4S-06L -08L -10L -12L KK6S-12L -16L 1/8 1/8 1/4 1/4 1/2 1/2 Bulkhead type with One-touch fitting Bulkhead type with One-touch fitting Applicable tubing O.D. mm Applicable tubing O.D. mm Body size Part no.

V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PFMC7501 5 L/min 500 L/min PFMC7102 10 L/min 1000 L/min PFMC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.

V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PF2MC7501 5 L/min 500 L/min PF2MC7102 10 L/min 1000 L/min PF2MC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.

Refer to the table for each pressure specification (page 110) Display/set pressure range Display/min. setting unit Power supply Used as switch output device 12 to 24 VDC (10%), and voltage ripple (p-p) 10% at max. voltage Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Electric spec. Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max.

4 A 2 A Power supply (Output) 24 VDC +10/-5%, 24 VDC +10/-5%, 8 A DC24 V +10/-5%, 4 A 2 A Enclosure IP67 (With manifold assembled) 1 Environment Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85%R.H.

Model/Valve Specifications Av x 10-6m2 Cv converted C [dm 3/(sbar)] b Cv Water, Oil, Steam Air Flow characteristics Maximum operating pressure differential (MPa) Min. operating pressure differential (MPa) 10 10 15 10 15 20 Connection Orifice Max. system pressure (MPa) Weight (g) Model Water AC DC AC DC AC DC AC Air Oil Steam size (mm) Thread VXP2130-02 0.7 0.7 1.0 0.7 1.0 1.0 1 4 740 500

Specifications Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50 (No freezing.

IDX-OM-W037-D PRODUCT NAME Thermo-dryer MODEL Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 This manual is intended to explain the installation and operation of the product. Only people who understand the basic operation of the product, or have basic knowledge and ability to handle industrial machinery, are allowed to work on the product.