Available protocols include PROFIBUS-DP®, DeviceNet™, CC-Link, Ethernet I/P™ and EtherCAT®, PROFINET, POWELINK and CC-Link IE Field™ Unit Type: Digital Input, Output, Input/Output, Analog Input, Output, Input/Output; Connector Type: M8, M12, D-Sub, Spring Cage Terminal; Up to IP67 enclosure rating with M8 and M12; CE, UL and RoHS compatible

Available protocols include PROFIBUS-DP®, DeviceNet™, CC-Link, Ethernet I/P™ and EtherCAT®, PROFINET, POWELINK and CC-Link IE Field™ Unit Type: Digital Input, Output, Input/Output, Analog Input, Output, Input/Output; Connector Type: M8, M12, D-Sub, Spring Cage Terminal; Up to IP67 enclosure rating with M8 and M12; CE, UL and RoHS compatible

The volume ratio of the EX510 SI unit is 60% more compact than the EX120.Communication protocol: CC-Link, DeviceNet, PROFIBUS DP , Applicable valves: SJ2/3000, SY3/5/7/9000, SQ1/2000 , RoHs compliant, 1M BRANCH CABLE, VALVE, EX500 SERIAL INTERFACE UNIT, 22, EX500 NO SIZE RATING, .11660 lb, ModelPort sizeMass (Bottom ported)Mass (Rear ported)Leakage02R1/4117 g89 g1 x 10?5 Pa?

Available protocols include Profibus-DP, DeviceNet, CC-Link, Ethernet I/P and EtherCat.Enclosure: IP67(Manifold Assembly), Operating temp. range: -10~50 C, Operating humidity range: 35~85%RH (no dew condensation), Standard: CE marking, UL recognition (CSA), Weight: 290g, INTERMEDIATE REINFORCING BRK, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .08761 lb, SeriesDescriptionModelActionNoteVol

Available protocols include DeviceNet, CC-Link, Profibus-DP and Allen-Bradley Remote I/O.The EX9 output block is designed to work with the EX126, EX250 and EX500 series serial interface products , Output blocks can be added to the valve manifold to effectively use any idle points for uses other than switching manifold valves , Individual NPN output or PNP output types are available depending

Decentralized Serial Wiring (GW System, 4 Branches) Series EX510 How to Order GW Unit Communication protocol MJ1 EX510-G MJ1 DN1 PR1 CC-Link DeviceNet PROFIBUS DP Power supply connector Specifications EX510-GMJ1 EX510-GDN1 EX510-GPR1 Model CC-Link Ver. 1.10 DeviceNet Release 2.0 PROFIBUS DP DP-V0 Protocol Version Note 1) Applicable system Communication connector Communication specification

Available protocols include PROFIBUS-DP®, DeviceNet™, CC-Link, Ethernet I/P™ and EtherCAT®, PROFINET, POWELINK and CC-Link IE Field™ Protocols: EtherNet/IP™, PROFINET, POWERLINK, Modbus TCP, CC-Link IE Field™,  DeviceNet™ and CC-Link; Output method: PNP, NPN; Enclosure: IP67(manifold assembly); Operating temp. range: -10~50° C; Standard: CE marking, UL recognition (CSA); Weight: 300g or less

Available protocols include PROFIBUS-DP®, DeviceNet™, CC-Link, Ethernet I/P™ and EtherCAT®, PROFINET, POWELINK and CC-Link IE Field™ Protocols: EtherNet/IP™, PROFINET, POWERLINK, Modbus TCP, CC-Link IE Field™,  DeviceNet™ and CC-Link; Output method: PNP, NPN; Enclosure: IP67(manifold assembly); Operating temp. range: -10~50° C; Standard: CE marking, UL recognition (CSA); Weight: 300g or less

KQ fitting, plug, Color: blue, Fitting sizes: 3.2, 4, 6, 8, 10, 12, 16, FITTING, CONNECTORS, KQ ONE TOUCH FITTING, DP, KQ 5/32, .00163 lb

Available protocols include Profibus-DP, DeviceNet, CC-Link, Ethernet I/P and EtherCat.Enclosure: IP67(Manifold Assembly), Operating temp. range: -10~50 C, Operating humidity range: 35~85%RH (no dew condensation), Standard: CE marking, UL recognition (CSA), Weight: 290g, CABLE (1M) HANDHELD TERMINAL, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, 1.55835 lb, ModelPort sizeMass (Bottom

(Only for units compatible with M12 PROFIBUS DP , CC-Link communication connectors) SY3000/5000 VQC1000/2000/4000 S0700 SV1000/2000/3000 D D D D Note) The SY3000/5000, VQC1000/2000/4000, and S0700 are not yet UL-compatible.

Available protocols include Profibus-DP, DeviceNet, CC-Link, Ethernet I/P and EtherCat.Enclosure: IP67(Manifold Assembly), Operating temp. range: -10~50 C, Operating humidity range: 35~85%RH (no dew condensation), Standard: CE marking, UL recognition (CSA), Weight: 290g, EX600 DIGITAL, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .93696 lb, ModelInput/Output typeConnectorInputOutputApplicable

Available protocols include Profibus-DP, DeviceNet, CC-Link, Ethernet I/P and EtherCat.Enclosure: IP67(Manifold Assembly), Operating temp. range: -10~50 C, Operating humidity range: 35~85%RH (no dew condensation), Standard: CE marking, UL recognition (CSA), Weight: 290g, DIGITAL OUTPUT (8), PNP, 4XM12, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .95614 lb, ModelOutputApplicable

Available protocols include Profibus-DP, DeviceNet, CC-Link, Ethernet I/P and EtherCat.Enclosure: IP67(Manifold Assembly), Operating temp. range: -10~50 C, Operating humidity range: 35~85%RH (no dew condensation), Standard: CE marking, UL recognition (CSA), Weight: 290g, DIGITAL OUTPUT MODULE, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, 1.02883 lb, ModelOutputApplicable wireCurrent

Available protocols include Profibus-DP, DeviceNet, CC-Link, Ethernet I/P and EtherCat.Enclosure: IP67(Manifold Assembly), Operating temp. range: -10~50 C, Operating humidity range: 35~85%RH (no dew condensation), Standard: CE marking, UL recognition (CSA), Weight: 290g, DIGITAL OUTPUT MODULE, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .88184 lb, ModelOutputApplicable wireCurrent

Available protocols include Profibus-DP, DeviceNet, CC-Link, Ethernet I/P and EtherCat.Enclosure: IP67(Manifold Assembly), Operating temp. range: -10~50 C, Operating humidity range: 35~85%RH (no dew condensation), Standard: CE marking, UL recognition (CSA), Weight: 290g, DIGITAL OUTPUT, 16 OUTPUT, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .80312 lb, ModelOutputApplicable wireCurrent

Available protocols include Profibus-DP, DeviceNet, CC-Link, Ethernet I/P and EtherCat.Enclosure: IP67(Manifold Assembly), Operating temp. range: -10~50 C, Operating humidity range: 35~85%RH (no dew condensation), Standard: CE marking, UL recognition (CSA), Weight: 290g, DIGITAL OUTPUT MODULE, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .66138 lb, ModelOutputApplicable wireCurrent

Anybus-CC PROFIBUS DP-V1GDS TM Siemens AG PLC STEP7 4. 4. 2 Anybus-CC PROFIBUS DP-V1[Properties-PROFIBUS interfacedialogue box dialogue box ok Anybus-CC PROFIBUS DP-V1 PROFIBUS 19 - 4. 4. 3 Anybus-CC PROFIBUS DP-V1 [Hardware Catalog] Input16word Input16word Input Total 57words Input16word Universal module I/O TypeInputLength9Unit:WordsConsistent overTotal length Output16word Output16word

2 (128 points) EX260 integrated-type (for output) serial transmission system EX500 Gateway Decentralized SI unit output polarity System (64 points) EtherNet/IP CC-Link CC-Link DeviceNet DeviceNet EtherCAT EtherNet/IP EtherNet/IP PROFINET PROFIBUS DP PROFIBUS DP A A B A B A B A B A B A Nil Positive common Negative common N EX600 integrated-type (I/O) serial transmission