OFF ON ON ON ON ON -20No.EX-OMN0034-B Station setting switch: Set the station number of SI unit Station number setting Address Station number x10 x1 0 0 Error (Default setting) 0 1 1 0 2 2 : : : 6 3 63 6 4 64 6 5 Error : : 9 9 : If a station number is set to 00 or over 65, the "LERR" LED will light up. The settable range depends on the number of occupied stations.
Action D S Rod end threads Double acting Single acting (spring extended) Rod end female threads (4 without threads) Rod end male threads Nil M Table 2 Auto switch specifications Table 1 Standard strokes Action Bore size (mm) 4 6 8, 10 4 6 8, 10 Standard stroke (mm) 4, 6, 8, 10 4, 6, 8, 10, 15 4, 6, 8, 10, 15, 20 4, 6 4, 6, 8 4, 6, 8, 10 Load voltage Lead wire length (m) Indicator light Wiring
Q = D __ 4 6 _ 1000 Q = (D d) __ 4 6 _ 1000 Formula (1) .
3.5 6 x M2 x 0.4 thread depth 4 (A, B, C common view) 3 0 0.02 3 Open: 22, Closed 14 0 0.02 Open: 16, Closed: 10 2 x M3 x 0.5 thread depth 6 (Thread for mounting attachment) 15: MHR2-15-A210 2 x M3 x 0.5 thread depth 6 (Thread for mounting attachment) Hexagon socket head cap screw M3 x 12 (3 included) Mass: 130 g Mass: 210 g +0.022 0 depth 6 3 x 3 (A, B, C common view) 6 x M3 x 0.5 thread
Model 6 6 6 ZH05DA ZH07DA 1/4" 1/4" 1/4" ZH05DA ZH07DA One-touch One-touch SUP. EXH. 6 6 8 ZH10DA 1/4" 1/4" 5/16" ZH10DA 8 10 10 ZH13DA ZH15DA 5/16" 3/8" 3/8" ZH13DA ZH15DA 10 12 12 ZH18DA ZH20DA 3/8" 1/2" 1/2" ZH18DA ZH20DA One-touch Oval release button is only available with 6. VAC. One-touch and screw-in connection SUP. VAC. EXH. Model SUP. VAC. EXH.
5 5 20 20 F7FFE -3276732766 0 1 0 0 4 Byte0 Byte1 CH0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB Byte2 Byte3 CH1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB -31No.EX-OMN0037CN-A -32No.EX-OMN0037CN-A EX600-AM B M12 (5 )4 2 2 M12 (4 ) No. 1 LED 2 () 3 () 4 5 6 () -33No.EX-OMN0037CN-A 1 24 V() 24 V() 2 + 3 0 V() 0 V() 4 0 V() 5 FE FE 1M12 (4 ) 1 1 24 V NC
Extension Cable 6. Part Identification 22 6-1. Monosashi-kun with brake 6-2. Controller 7. Installation & Wiring 23 7-1. Installation 7-1-1 Installation of Cylinder 7-1-2 Installation of Controller 7-2. Wiring 7-2-1 The connection of Power Supply 7-2-2 The connection of Extension Cable 7-3.
Instance common service Service code Description 0Eh Get_Attribute_Single 10h Set_Attribute_Single -27No.EX-OME0015-F 6. Discrete Output Point Object (Class ID: 09h) 6-1. Class attribute ID Access rule Description Value 6-2. Class common service Service code Description 6-3.
N.C. type is recommended. 15 6.
6 @3 @4 e !7 w i t q A A @7 #3 @9 #0 #1#2 !8 !9 #4 @8 @6 !4 !5 Description Material Note Component Parts Description Material Note Component Parts No.
6 !7 !8 q w e r t y u i o !0 !1 !2 !3 !4 !
6, !8. 4 Piston rod Stainless steel 1 5 Piston Aluminum alloy 1 6 Cushion ring Rolled steel 2 Trivalent zinc chromated * Seal kits consist of items !3 to !6, !8 and can be ordered by using the seal kit number corresponding to each bore size. * The seal kit includes a grease pack (10 g for 32 to 50, 20 g for 63 and 80, 30 g for 100).
IDF60/70/80/90 Series 6.2 Reset the Thermal relay and High Pressure Switch 6-3 IDX-OM-X011 Chapter 6 Troubleshooting 6.2 Reset the Thermal relay and High Pressure Switch IDF190D/240D Series 6-4 IDX-OM-X011 Chapter 7 Documents Chapter 7 Documents 7.1 Specifications Models Item IDF190D IDF240D Standard condition (ANR) Note 1) 50Hz 32 43 60Hz 38 50 Air flow capacity m3/ min Compressor inlet
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
0 200 6 0 150 6 0 100 Stroke F E Stroke F E 20 7 900 20 7 850 18 6 800 18 6 750 16 5 700 16 5 650 14 4 600 14 4 550 22 8 950 22 8 1000 13 Electric Actuator/Maintenance Guide 1 Be sure to read before handling.
One-touch fitting for 4 C4 SY3000 2 position double One-touch fitting for 6 C6 One-touch fitting for 4 C4 2 One-touch fitting for 6 C6 For DC SY5000 One-touch fitting for 8 C8 5 24 VDC 6 12 VDC SY9000 has no bracket.
Top mounting (Body tapped) L4 L5 L6 Size Screw Max. screw-in Height Counterbore depth [mm] [mm] depth [mm] 10 M5 x 0.8 6 6 3.9 20 M6 x 1 6 8 4.5 30 M6 x 1 6 8 4.5 50 M8 x 1.25 8 8.5 5.6 -28- With interchangeable plate 4.
Pressure gauge 6 Union tee fitting Flow meter O.D. 6 mm, I.D. 4 mm tube (Length 10 mm) Ionizer Fig. 1: Flow rate characteristics measuring circuit 446 Technical Data IZN10 Series Ozone Concentration (1) Energy saving static neutralization nozzle/IZN10-01 (2) High flow rate nozzle/IZN10-02 0.03 IZS IZN IZN IZF Ionizer ZVB 0.02 Concentration [ppm] Energy saving static neutralization nozzle/