Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 3 [110 VAC (115 VAC)], Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 4 [220 VAC (230 VAC)], Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: DO (Type D, DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: DO (Type D, DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: G (Grommet, Lead Wire Length: 300mm), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: KO (M12 Connector, w/o Cable), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 1 (100 VAC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 3000, Thread: N (NPT), Port Size: 03 (3/8), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: RZ (Flow Direction: Right to Left; Name Plate and Pressure Gauge in Imperial Units)
Size: 30 (3/8), Port Size: 03 (3/8, Size 30), Accessories: None, Bowl: 8 (Metal Bowl w/Sight Glass), Flow Direction: Flow Direction - Left to Right
Size: 30 (3/8), Port Size: 03 (3/8, Size 30), Accessories: None, Bowl: 8 (Metal Bowl w/Sight Glass), Flow Direction: R (Flow Direction - Right to Left)
Size: 30 (3/8), Port Size: 03 (3/8, Size 30), Accessories: None, Handle Orientation: Handle Down
Size: 30 (3/8), Port Size: 03 (3/8, Size 30), Accessories: None, Handle Orientation: Y (Handle Up)
Size: 30 (3/8), Port Size: 03 (3/8, Size 30), Accessories: None, Bowl: 8 (Metal Bowl w/Sight Glass, Size 30 & 40), Flow Direction: Flow Direction - Left to Right
Size: 30 (3/8), Port Size: 03 (3/8, Size 30), Accessories: None, Bowl: 8 (Metal Bowl w/Sight Glass, Size 30 & 40), Flow Direction: R (Flow Direction - Right to Left)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order: X109
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: R (Bracket), Calibration Certificate: A (Calibration