Description Material AMF150 AMF250 AMF350 AMF550 AMF650 AMF850 Glass fiber NBR Element assembly 4 AMF-EL150 AMF-EL250 AMF-EL350 AMF-EL550 AMF-EL650 AMF-EL850 AMF-EL450 With gasket and O ring AMF800 to 1000 HAl AT IDl Component Parts Part No. AMF800/900/1000 SGP-E: SS400 SGP-E: SS400 AMG No.
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test was performed at both energized and deenergized states in the axial direction and at the right angles to the main valve and armature.
20 or less 30 or less 50 or less 80 or less Effective area (mm2) 35 60 90 160 270 440 590 960 2 0.2 Inlet pressure (MPa) Noise level (dB) (A) 0.1 1 4 AN200-02 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233 74 60 820 263 86 70 0.05 AN300-03 3 8 AN400-04 1 2 0.02 AN500-06 3 4 0.01 AN600-10 1 1 1 0.005 AN700-12 1 4 AN800-14 1 2 AN900-20 0.002 50 200 1000
Do not drop, bump or apply excessive impact (1000 m/s2) when handling. Even if the switch body is not damaged, the switch may suffer internal damage that will lead to malfunction. 2. Hold the product from the body side when handling. When raising and moving the product, do not raise it by holding the lead wire only, but hold the body. It may cause malfunction due to broken contacts.
Particle Characteristics (Reference) Data 1000 Fill the flow path with sulfuric acid and leave it for 30 minutes. After disposing the sulfuric acid, flush the flow path out with deionized water and measure the resistance rate of the fluid that is discharged from the downstream side. A quick recovery time indicates little liquid pool.
VCW 20 1 G Clip Series Lead wire length 20 30 40 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 Class 2 Class 3 Class 4 Flat head screwdriver Voltage Solenoid coil 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Electrical entry Insert a flat head screwdriver into the hook section of the clip groove.
A Withstand pressure V, 1 minute, AC Station 11 1000 SOL. B 24 () (+) Black White 12 () (+) Yellow Red SOL. A Insulation resistance M/km, 20C Station 12 5 or less SOL. B 25 () (+) White None Note) The minimum bending radius for D-sub connector cables is 20mm. COM. 13 (+) () Orange Red Note) Negative COM spec. Positive COM spec.
0.5 0.6 0.7 0.8 0.9 1.0 200 CM2 20 50% 70% 10% 30% 150 Stroke mm AS2201F -01-06 AS2200-01 70% 100 50 10% 30% 50% 0 200 CM2 25 150 Stroke mm AS2201F -01-06 AS2200-01 100 50 0 ANA1 -C08 T0604 200 CM2 32 150 Stroke mm AS2201F -01-06 AS2200-01 100 50 0 200 CM2 40 150 Stroke mm AS2201F -02-06 AS2200-02 100 50 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000
CE2 ML2B Graph (1) Graph (2) RSA50, 63, 80 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 C J G5-S 1.0 1300 1300 RSH80 RSA80 RSH63 RSA63 RSH50 RSH50 RSA50 80 0.9 Operating pressure P [MPa] 1200 1200 CV 0.8 1100 1100 0.7 MVGQ 1000 1000 0.6 900 900 0.5 CC 63 80 Load weight m [kg] Load weight m [kg] 800 800 0.4 50 0.3 RB 700 700 0.2 600 600 J 0.1 63 500 500 50 1000 2000 3000 4000 5000
OUT1: Green, OUT2: Red IP40 5 to 50C 1000 VAC for 1 minute between terminals and housing 50 M or more (500 VDC measured via megohmmeter) between terminals and housing 2% F.S.
How to Order AL800 AL 23 80 12 0 R AL900 Semi-standard R Flow direction: Right Left Body size Port size Semi-standard Lubricator 1 1S-1 1S-2 2 3 6 8 1000 cm3 tank 1000 cm3 tank with switch (Bottom limit ON) 1000 cm3 tank with switch (Bottom limit OFF) Metal bowl With drain cock Nylon bowl (Including sight dome) Metal bowl with level gauge Symbol 12 14 20 4 1 1 1 2 2 1 80 90 1 2 2 1 Thread
with power supply polarity protection) Power supply voltage Current consumption 40 mA or less Switch output NPN or PNP open collector: 2 outputs (selectable) Maximum load current 80 mA Maximum applied voltage 28 V (with NPN output) Residual voltage 2 V or less (with load current of 80 mA) Response time 2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000
(Page 64) 2001 0x07D1 0 R Process data Conversion formula Intercept b F32 N 2002 0x07D2 0 R Peak value U16 0 N 2003 0x07D3 0 R Bottom value U16 0 N information Diagnostic Number of pressurizing errors U16 0 N 0 ~ 1000 2004 0X07D4 0 R 1: "R" means Read and "W" means Write. 2: Refer to the table below for the symbol.
Refer to Features 1 for details. 57 Filter Regulator AW10 to 40 Flow Characteristics (Representative values) Condition: Inlet pressure 0.7MPa AW10 AW30 Rc 3/8 AW40-06 Rc 3/4 M5 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure MPa Outlet pressure MPa Outlet pressure MPa 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 150 125 100 75 50 25 0 1000 0 3000 4000 1000 2000 Flow rate L/min (ANR) 0 0 0 500
40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.
For product installation at a place of high altitude of 1000 meters or more, select a thermo-chiller of the applicable capacity referring to the table below. 1. Max. ambient temp.: Use the product in lower ambient temperature than the described value at each altitude. 2.
AS301FS, AS311FS AS401FS, AS411FS Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10, 11, 12 10, 11, 12 12, 13, 16 12, 13, 16 1500 1000 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 08, 09 06, 07 1000 500 500 0 0 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the applicable tubing
350, 400, 450, 500, 600, 700, 800 1300 12-CY3R40 40 Rc1/4 NPT1/4 G1/4 12-CY3R50 12-CY3R63 50 63 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special order.
One-touch fitting is mounted on the plate. 600 mm Note 1000 mm Insertion error checking ridge If only the fitting is needed, order with one of the part numbers below. e Fitting Part No. Description Barb fitting One-touch fitting PV060-73-1A KJS02-M3 Socket Part no.
Voltage limit V, 1 min, AC 1000 Insulation resistance MW/km, 20C 5 or more * The minimum bending inner radius of D-sub connector cable is 20 mm. 43 ZK2mA Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for safety instructions.