Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: FB (PROFINET - 16 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 2 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 2 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 2 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting)
Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: DB (EtherCAT - 16 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 2 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Actuation: 2 (2-position Double), Mounting/Porting: 3 (Top Ported), Seal: 0, Back Pressure Check Valve: H (Built-in), Pilot Valve: Standard (0.7 MPa), Coil Specification: Standard, Voltage: 5 (24 VDC), Light/Surge Suppressor/Common Specification: w/o Light/Surge Voltage Suppressor, Non-polar, Manual Override: Non-locking Push Type, A, B Port Size: C6 (ø6 One-touch Fitting)
Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: A (2 NPN Outputs), Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)
Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: A (2 NPN Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)
Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: A (2 NPN Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)
Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: Unit Switching Function, Operation Manual: N (None), Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)
Series: 5 (SY5000), Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot Type: Internal Pilot, Coil Specification: Standard, Rated Voltage: 5 (24VDC), Electrical Entry: H (Grommet Lead Wire 0.6m), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A,B Port Thread: C6 (Body Ported ø6 One-touch Fitting)
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: ZE (EtherNet/IPâ„¢), Input Block Stations: 2 Stations, Input Block Type, Common Spec: C (Positive Common, M8, 4 Inputs), Valve Stations: 2 Stations, P,E Port Location, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: C6 (ø6 One-touch Fitting)
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: ZE (EtherNet/IPâ„¢), Input Block Stations: 2 Stations, Input Block Type, Common Spec: F (Negative Common, M8, 4 Inputs), Valve Stations: 2 Stations, P,E Port Location, SUP/EXH Assembly: B (Port Location Both Sides, Internal Pilot), A, B Port Size: C6 (ø6 One-touch Fitting)
Actuation: 1 (2 Position Single), Seal: 1 (Rubber Seal), Function: N (Negative Common), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: C6 (Side Ported ø6 One-touch Fitting), Plug Mount Port: B [Port 2(B)], Manifold Block: M (w/Manifold Block), CE Compliant: Q (CE Compliant)
Actuation: 1 (2 Position Single), Seal: 1 (Rubber Seal), Function: N (Negative Common), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: C6 (Side Ported ø6 One-touch Fitting), Plug Mount Port: B [Port 2(B)], Manifold Block: w/o Manifold Block, CE Compliant: Q (CE Compliant)
Actuation: 2 [2 Position Double (Double Solenoid)], Seal: 1 (Rubber Seal), Function: DN (D + N), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: C6 (Side Ported ø6 One-touch Fitting), Plug Mount Port: None, Manifold Block: w/o Manifold Block, CE Compliant: Q (CE Compliant)
Actuation: 2 [2 Position Double (Double Solenoid)], Seal: 0 (Metal Seal), Function: DN (D + N), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: B (Locking Type, Tool Required), Cylinder Port: C6 (Side Ported ø6 One-touch Fitting), Plug Mount Port: None, Manifold Block: w/o Manifold Block, CE Compliant: Q (CE Compliant)
Actuation: 2 [2 Position Double (Double Solenoid)], Seal: 0 (Metal Seal), Function: DN (D + N), Voltage: 5 (24VDC), Electrical Entry: LO (Plug Connector w/o Connector), Manual Override: Non-locking Push Type, Tool Required, Cylinder Port: C6 (Side Ported ø6 One-touch Fitting), Plug Mount Port: None, Manifold Block: w/o Manifold Block, CE Compliant: Q (CE Compliant)
Model: 10S (Side Ported), SI Unit Specification: EB (EtherNet/IPâ„¢ - 16 Outputs - Connector M12), SI Unit Ouput Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 2 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting, Straight, Metric)
Model: 10S (Side Ported), SI Unit Specification: 0 (w/o SI Unit), SI Unit Ouput Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 2 Stations, P,E Port Entry: B (Both Sides, 2 to 16 Stations), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A,B Port Size: C6 (ø6 One-touch Fitting, Straight, Metric)