Stations: 02 (2 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 04 (1/2)
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 04 (1/2)
Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: Rc, Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Range: 04 (0.5 to 4 L/min), Supply/Return Port Size: 03 (3/8)
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: F (G), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 06 (3/4)
Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 04 (1/2)
Stations: 02 (2 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 04 (1/2)
Stations: 02 (2 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 04 (1/2)
Stations: 02 (2 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 04 (1/2)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: 02 (Rc1/4), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: 02 (Rc1/4), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: C4 (ø4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: C4 (ø4), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: 02 (Rc1/4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: 02 (Rc1/4), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: C6 (ø6), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: 02 (Rc1/4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)