Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/o Connector, Light/Surge Voltage Supprressor:
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/o Connector, Light/Surge Voltage Supprressor:
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/Lead Wire 300mm, Light/Surge Voltage Supprressor: w/Light Surge
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Port Exhaust, Rc1, G1, NPT1, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: Port Exhaust, Rc1, G1, NPT1, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F06 [Vacuum: G3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/Lead Wire 300mm, Light/Surge Voltage Supprressor
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.35 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/Lead Wire 300mm, Light/Surge Voltage Supprressor
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/o Connector, Light/Surge Voltage Supprressor:
Suction Flow Rate: 600 L/min (ANR, Supply Pressure: 0.35 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: M Plug Horizontal Connector w/Lead Wire 300mm, Light/Surge Voltage Supprressor: w/Light Surge Voltage
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/o Connector, Light/Surge Voltage Supprressor
Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 24 VDC, Electrical Entry: L Plug Vertical Connector w/o Connector, Light/Surge Voltage Supprressor: w/Light Surge Voltage
Operating Pull Force(kN): 0.3, Allowable Misalignment U(mm): 0.5, Allowable Angular Misalignment V(deg): ±5, Applicable cylinder bore size(ø): 20, Applicable cylinder nominal thread: M8 × 1
Operating Pull Force(kN): 0.3, Allowable Misalignment U(mm): 0.5, Allowable Angular Misalignment V(deg): ±5, Applicable cylinder bore size(ø): 20, Applicable cylinder nominal thread: M8 × 1.25
Operating Pull Force(kN): 0.8, Allowable Misalignment U(mm): 0.5, Allowable Angular Misalignment V(deg): ±5, Applicable cylinder bore size(ø): 25, Applicable cylinder nominal thread: M10 × 1.5
Operating Pull Force(kN): 0.8, Allowable Misalignment U(mm): 0.5, Allowable Angular Misalignment V(deg): ±5, Applicable cylinder bore size(ø): 25/32, Applicable cylinder nominal thread: M10 × 1.25
Operating Pull Force(kN): 0.8, Allowable Misalignment U(mm): 0.5, Allowable Angular Misalignment V(deg): ±5, Applicable cylinder bore size(ø): 32, Applicable cylinder nominal thread: M10 × 1
Operating Pull Force(kN): 1.25, Allowable Misalignment U(mm): 0.75, Allowable Angular Misalignment V(deg): ±5, Applicable cylinder bore size(ø): 32/40, Applicable cylinder nominal thread: M12 × 1.25
Operating Pull Force(kN): 1.25, Allowable Misalignment U(mm): 0.75, Allowable Angular Misalignment V(deg): ±5, Applicable cylinder bore size(ø): 32/40, Applicable cylinder nominal thread: M12 × 1.75
Operating Pull Force(kN): 1.25, Allowable Misalignment U(mm): 0.75, Allowable Angular Misalignment V(deg): ±5, Applicable cylinder bore size(ø): 40, Applicable cylinder nominal thread: M14 × 1.5
Operating Pull Force(kN): 3.1, Allowable Misalignment U(mm): 1, Allowable Angular Misalignment V(deg): ±5, Applicable cylinder bore size(ø): 50, Applicable cylinder nominal thread: M16 × 1.5