FKM MHZAJ2-J6F Si MHZAJ2-J6S 4 Series MHZA2-6/MHZAJ2-6 Parallel Type/Compact Series Dimensions/(mm) Standard Type 1in = 25.4mm MHZA2-6 Double acting/Single acting Basic Type 12 Scale: 100% 5 2-M2 x 0.4 thread depth 4 (mounting thread) 2-M3 x 0.5 through (mounting thread) Prepared hole dia. 2.6 through (mounting hole) 0 -0.1 13.6 4 20 12 20 When closed 8 0 -0.4 When open 12 1 +0.022 0 7H8
Weight g d T H D1 D2 D3 L1 L2 L3 Model 4 ASD230FM-M5-04 9.3 12 29.4 17.5 12.9 29.6 33.8 28.8 9.6 10 34.6 M5 x 0.8 8 30.1 25.1 7.8 11.7 6 ASD230FM-M5-06 11.6 13 32.5 20.6 13.7 34.6 39.6 6 ASD330FM-01-06S 14 11.6 29 38.5 22.9 13.7 36.1 31.1 14.2 11.8 R1/8 12 32.1 27.1 10.6 15.8 33.9 38.9 8 ASD330FM-01-08S 15.2 31 44.8 28.2 18.5 6 ASD430FM-02-06S 12.8 53 43.5 25.2 17 18 8 ASD430FM-02-08S 36.8
85.2 124.8 150.1 NX 7.3 10.5 14 PA 44 63 113 PB 80 110 132 PC 4 9.4 8.5 PP 5.3 8 16 Q 140 185 290 Model MY2HT16G MY2HT25G MY2HT40G X 7 9 12 Y 5 8 12 Z 160 210 330 U 5 6 8 UU 3 4.4 2 VV 10.5 15.3 29 XX 12 14 23 "P" indicates cylinder supply ports.
Check if there is a noise source nearby. (2) Check if the power supply voltage is in the range 12 to 30 VDC. (2) Supply power in the range 12 to 30 VDC. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range. "LLL" is displayed.
(mm) Applicable tubing KSH04-M5 KSH04-M6 KSH04-01S KSH06-M5 KSH06-M6 KSH06-01S KSH06-02S KSH08-01S KSH08-02S KSH08-03S KSH10-02S KSH10-03S KSH10-04S KSH12-03S KSH12-04S M5 x 0.8 M6 x 1 36.5 9 12 37 33 8 10.4 16 2.5 4.0 4.0 4 38 37.5 38 39.5 42.5 44 47 48 54 55 57.5 57 60 14 34 33.5 34 35.5 36.5 40 41 41.5 48 48.5 49.5 50.5 52 1 8 M5 x 0.8 M6 x 1 12 2.5 3 4.0 4.0 5.6 5.6 12 8 6 12.8 14 17
Flow Rate and Sonic Conductance Model AS22l1FSl-U01 AS22l1FSl-U02 AS32l1FSl AS42l1FSl Flow Direction Symbols on Body Meter-out Meter-in Metric size 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Symbol Tubing O.D.
M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
50F J (Valve open) Indicator (Option) Pilot port E 12(P1), 10(P2) Port size: refer to table below P1 P2 H H D B A 32 B C G F 4 x 2 x 18 mounting hole A Applicable flange 1(A), 2(B) Pilot port 12(P1), 10(P2) A B C D E F G H J Model VND50D-32F VND60D-40F VND70D-50F 8 10 12 50 40 32 1 8 1 4 1 4 130 150 180 211.5 227 251 135 140 155 135 147 163.5 20 24 24 100 105 120 36 42 54 12 12 14 638 A
M12 connector pin number G1/2 terminal number X X VP544(R)/744(R)-X538 Internal pilot External pilot External pilot/With check valve r (32) w (12) r (32) w (12) r (32) w (12) 2(A) 2(A) 2(A) (31) e (11) q (31) e (11) q (31) e (11) q 3(R) 3(R) 3(R) r (32) w (12) r (32) w (12) r (32) w (12) 3(R) (31) e (11) q 3(R) (31) e (11) q 3(R) (31) e (11) q 1(P) 1(P) 1(P) X X VP544(R)/744(R)-X555 Internal
10-12-28
Counter CEU5 Wiring with External Equipment
Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Connector Terminal conduit DIN terminal Grommet 12 V 2-wire 24 V PLC Relay, PLC 100 V, 200 V Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC Yes 24 V 12 V 3-wire (NPN) 3-wire (PNP)
M2 M3 m2 m3 m4 10 15 25 1 2 1 2 2 2 1.4 CY1F 1.5 3 1.5 5 5 5 2 14 20 14 12 12 12 12 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.
SI SI -Enable / 68 No.EX-OMU0020CN . 12-2 SF LED () No. 6.2 3 LED Link Power Margin 2dB . 12-3 US LED No. 1 US1 LED SI US1(/) SI 2 US1 LED US1(/) 3 US2 LED SI US2(/) SI 4 US2 LED US2(/) 69 No.EX-OMU0020CN . 12-4 No. SI 1 US2(/) SI 12.2. EX245-DX1 . 12-5 EX245-DX1 No. / 1 / US1(/ SI / / 2 EX245-DX1 LED / / / 12.3.
System error (Er0, 4, 6, 8, 40) is displayed. (2) Check if the power supply voltage 6 is in the range 12 to 24 VDC 10%. (2) Supply power in the range "HHH" is 12 to 24 VDC 10%. displayed. (1) Reset applied flow to a (1) Check if the flow exceeds the level within the set flow range.
5.6.3 Key click sound setting . 5-12 5.6.4 Band width setting for the TEMP READY signal . 5-12 5.6.5 Setting of time for TEMP READY signal for out of range . 5-13 5.6.6 Anti-freezing function setting . 5-13 5.6.7 Fan output upper limit . 5-13 5.6.8 Electric conductivity function setting . 5-14 5.6.9 Reset the setting . 5-14 5.6.10 Reset of the accumulated operating time of the dust-proof
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 CH1 abnormal low tank fluid level 1 CH1 low tank fluid level 2 CH2 Abnormal low tank fluid level 3 CH2 low tank fluid level 4 Reservation 5 Fan failure *1 Alarm flag 1 6 Air exhaust fan failure *2 7 Reservation 8 CH1 abnormal rise of circulating fluid
Refer to How to Order for the standard model numbers. 12, 16 1 to 249 Applicable stroke 20, 25, 32 1 to 399 mm) 40 to63 5 to 395 Part no.: 12-MGPL20-39Z A spacer 1 mm in width is installed in the 12-MGPL20-40Z. C dimension is 77 mm. Example 6 6. Precautions on Selection 1) Confirm the specifications.
12 bit Ry1B Ry1A Ry19 Ry18 ID 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 12 1 1 0 0 44 - 13.
Remote (Wireless channel 002) byte 24 byte 25 Reserved Total 26 byte 12 byte : When the setting of diagnostic allocation is "Detailed", areas of the number of remote set at the Number of remote connection are occupied.
5.5.1 Alarm buzzer sound setting . 5-12 5.5.2 Alarm buzzer sound setting and checking . 5-12 5.6 Alarm customize function . 5-13 5.6.1 Alarm customize function. 5-13 5.6.2 Alarm customize function setting and checking . 5-13 5.6.3 Setting of temperature alarm monitoring method and alarm generation timing . 5-21 5.7 Data reset function . 5-23 5.7.1 Data reset function . 5-23 5.7.2 Method