Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: Q (Stainless Steel Body & Shading Coil, PTFE (FPM) Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: N (NPT), Voltage: 4 (220VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 0 (Energized Open/N.C.), Option: S (Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil), Port Size: 10 [1 (25A)], Thread: T (NPTF), Voltage: 3 (110VAC 50/60HZ), Lead Wire: C (Conduit)
Solenoid: No.2 Solenoid, Body Option: 6 (25A), Style: 2 (Energized Closed/N.O.), Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: F (G), Voltage: 4 (220VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Model: 10 (200 L/min [ANR]), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 3 (Switch Output PNP), Thread: T (NPTF), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector)
Model: 10 (200 L/min [ANR]), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 0 (Current Style 4~20mADC), Monitor Output: 3 (Switch Output PNP), Thread: T (NPTF), Port Size: 1 [1/8 (1000)], Accessory: None, Cable Connector: N (w/oCable Connector)
Model: 10 (200 L/min [ANR]), Pressure Range: 3 (0.005~0.5MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 3 (Switch Output PNP), Thread: T (NPTF), Port Size: 1 [1/8 (1000)], Accessory: None, Cable Connector: S (Straight Style 3m)
Model: 10 (200 L/min [ANR]), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: 3 (Voltage Style 0~10VDC), Monitor Output: 3 (Switch Output PNP), Thread: T (NPTF), Port Size: 1 [1/8 (1000)], Accessory: None, Cable Connector: N (w/oCable Connector)
Body Size: 60, Thread: N (NPT), Port: 10 (1), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: ST (S + T), Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 50, Thread: N (NPT), Port: 10 (1), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: TV (T + V), Semi-Standard 1: 3 (Lubricator w/Drain Cock), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 10 (1), Thread: T (NPTF)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 1 (Direct Manual Override), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 10 (1), Thread: T (NPTF)
Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 1 (Direct Manual Override), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 10 (1), Thread: T (NPTF)
Function: 4 (3 Position Exhaust Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 10 (1), Thread: T (NPTF)
Body Size: 6 (1), Port Size: 10 (1), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Electrical Entry: T (Conduit Terminal), Light/Surge Voltage Suppressor: Z (with Light/Surge Voltage Suppressor), Actuation Type: A (N.C.), Thread: N (NPT), Made to Order: 80 (Double Solenoid)
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Attachment: TV (T + V), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: D (N.O. Float Type Auto Drain), Attachment: TV (T + V), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: TV (T + V), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: R (Flow Direction: Right to Left)
Function: 2 (2 Position Double), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: R (Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: Double, A, B Port: C4 (ø4 One-touch Fitting)
Function: 1 (2 Position Single), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: U (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: Double, A, B Port: C4 (ø4 One-touch Fitting)
Function: 1 (2 Position Single), Pilot: Internal Pilot, Voltage: 5 (24VDC), Light & Surge Suppressor: R (Surge Suppressor), Manual Override: Non-locking Push Style, Manifold Block: T (Tie Rod Base Type 10 Manifold Block), Manifold Wiring: Double, A, B Port: C6 (ø6 One-touch Fitting)