Enclosure IP65 Ambient temperature range Operation: -10 to 60 oC, Storage: -20 to 70 oC (No condensation or freezing) Environ ment Ambient humidity range Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 250 VAC, 1 minute, Between lead block and case Insulation resistance 50 M or more at 50 VDC Between lead block and case Temperature characteristic 2% F.S. or less (0 to

Power supply voltage effect 1%F.S. or less based on the analog output at 18 V ranging from 12 to 24 VDC Enclosure IP40 Ambient temperature range Operation: 0 to 50 oC, Storage: -10 to 70 oC (No condensation or freezing) Environ ment Ambient humidity range Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 1000 VAC, 50/60 Hz, 1 minute, between terminals and housing Insulation

Separate the branch cable away from noise sources. 70 No.EX-OMS0014-A Fault No. 17 Fault Possible cause Investigation method Countermeasures Polarity of the input unit and input device including sensor are not compatible. Use an input device polarity compatible with the polarity of the input unit. Check that the polarity of the input unit and the input device are compatible.

fitting without cutting the tube.When the tubing is re-inserted into the One-touch fitting, confirm that the tubing goes through the release button smoothly. tube tube tube 3.2 1/8 44 or more 35 or more 25 or more 16 or more 4 5/32 56 or more 44 or more 26 or more 20 or more 3/16 67 or more 52 or more 38 or more 24 or more 6 84 or more 66 or more 39 or more 30 or more 1/4 89 or more 70

Bus cable specification Termination Bus length [m] Length-related resistance [m/m] Cross-section [mm2] resistance [] 040 <70 0.250.34 124 40300 <60 0.340.6 150300 300600 <40 0.50.6 150300 6001000 <26 0.750.8 150300 For drop cables, a wire cross-section of 0.25 to 0.34 mm2 would be an appropriate choice in many cases.

of Product parts 28 Mounting and Installation 29 Wiring 29 Specification 30 Specifications 30 Dimensions 30 -1No.EX-OMN0028-B Maintenance 32 Troubleshooting 33 Parameter Setting 42 Parameter definition and setting 42 Hardware Configuration 55 GSD file and icon 55 Configuration layout 55 SIEMENS PLC S7TM connection method 56 Parameter setting at PLC 59 I/O Map 61 Diagnostic 62 Accessories 70

Enclosure IP40 Ambient temperature range Operation: 0 to 50 oC, Storage: -20 to 70 oC (No condensation or freezing) Environ ment Ambient humidity range Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 1000 VAC or more, 50/60 Hz, 1 minute, Between lead block and case Insulation resistance 50 M or more at 500 VDC Between lead block and case Temperature characteristic 2%F.S

OUTLET BALL VALVE (F) AUTO DRAIN C DRAIN TUBE TERMINAL LENGTH:1m) (O.D.10, BLOCK J P K L2 N1 M 13 4x POWER SUPPLY ENTRY 911)[OPPOSITON] (WIRE H measuremm Model Port size A B C D E F G H J K L M N P IDU22E R1 325 775 1153 93 445 123 5 279 46 50 13 353 85 600 379 1258 64 550 135 0 290 388 680 414 IDU37E R11/2 360 855 IDU55E R2 470 1345 53 530 1440 360 30 500 75 700 526 IDU75E 1480 1575 70

. -77No.EX-OMW0006-D Remote specifications Models EX600-WSV1 EX600-WSV2 For control and input (US1) Power supply voltage 24 VDC 10% Electrical specifications Current consumption 70 mA or less Power supply voltage 24 VDC 10% For output (US2) Max. supply current 4 A Number of inputs Input size Max. 128 points (increase or decrease by 16 points) Number of outputs Output size Max. 128 points

E2E-X2D1-N Output type Normally open Power supply voltage (Operating voltage range) 12 to 24 VDC (10 to 30 VDC), Ripple 10% or less (P-P) Current consumption (Leakage current) 0.8mA or less Response frequency 1.5 kHz Control output (Switching Capacity) 3 to 100 mA Indicator light Operation indication (Red LED), Set operation indication (Green LED) Ambient temperature -25 to 70 (No freezing

(fluid: Dry air) Temperature characteristics 2%F.S. max. (15 to 35 C) 5%F.S. max. (0 to 15 C, 35 to 50 C) Pressure characteristics 5%F.S. max. (0.35 MPa reference) Rated pressure range -70 kPa to 750 kPa Proof pressure 1 MPa 50 msec. Response time (when "Select response time" wire (white) is connected to GND, response time is 1 sec.)

Recommended Piping Conditions Unit:mm Mounting pitch A Tubing size Straight-line Pipe length Nylon tube Soft nylon tube Polyurethane tube 4,5/32" 56 or more 44 or more 26 or more 20 or more 6 84 or more 66 or more 39 or more 30 or more 1/4" 89 or more 70 or more 57 or more 32 or more 8, 5/16" 112 or more 88 or more 52 or more 40 or more -8- Warning Air Supply Operating environment Warning

Display Display part Displayed digit: 3 digits 7 segments, Colour: Red Indicator LED (output) LED is ON when output is ON OUT1: Green OUT2: Red Supply voltage 12 to 24 VDC 10% Power consumption (no load) 70 mA or less 80 mA or less -36No.PF-OMO0012-E Model PF2W704(T) PF2W720(T) PF2W740(T) PF2W711 Enclosure IP65 Operating temperature range Operation: 0 to 50 C, Storage: -25 to 85 C (no condensation

spacer is not available for 10 and MY1HT series) -5 -10 -25 -30 -15 -20 -35 -40 0 5.6 to 11.2 0 to 5.6 11.2 to 16.8 MY116 Without spacer Short spacer Long spacer 0 to 6 12 to 18 6 to 12 MY120 Without spacer Short spacer Long spacer 0 to 11.5 11.5 to 23 23 to 34.5 MY125 Without spacer Long spacer Short spacer 0 to 12 12 to 24 24 to 36 MY132 Short spacer Without spacer Long spacer -20 -30 -40 -70

Specifications 6 10 16 20 25 32 Bore size Air Fluid M5x0. 8 Rc1/8 Port size 0. 7Mpa Max. operating pressure 1. 05MPa Without switch: -10 to +70 (No freezing) With switch: -10 to +60 (No freezing) 50 to 500mm/s Proof pressure Ambient and operating fluid temperature Piston speed Double acting D type 0. 0125 Single acting T type 0. 0062 0. 025 0. 05 0. 1 0. 2 0. 3 Allowable kinetic energy

Connectors for Series VEX3 Body Sizes 50, 70, 90 How to Use DIN Terminal Electrical Connection(DIN Terminal) Disassembly 1) After loosening the screw (1), then if the housing (2) is pulled in the direction of the screw (1), the connector will be removed from the body of equipment (solenoid, etc.). 2) Pull the screw (1) out of the housing (2). 3) On the bottom part of the terminal block (3

. / (420) 5-414 24611 NORWAY / (47) 67 12 90 20 DENMARK / (45) 70 25 29 00 POLAND / (48) 22-548 50 85 FINLAND / (358) 9-859 580 PORTUGAL / (351) 2 610 89 22 FRANCE / (33) 1-64 76 1000 SPAIN / (34) 945-18 4100 GERMANY / (49) 6103 4020 SWEDEN / (46) 8-603 0700 GREECE / (30) 1342 6076 SWITZERLAND / (41) 52-396 3131 HUNGARY / (36) 1-371 1343 TURKEY / (90) 212 221 1512 IRELAND / (353) 1-403 9000

Specifications Fluid Air Proof pressure 1.05MPa Maximum operating pressure 0.7MPa 12, 16 0.03MPa Minimum operating pressure 20 ~ 40 0.02MPa 50 ~ 100 0.01MPa -10 ~ +70 C, Built-in magnet type: -10 ~ +60 C (with no freezing) Ambient and fluid temperature Lubricant Non-lube (Do not lubricate) CM2YCG1YCA2Y +1.4 0 Stroke length tolerance (mm) CQSYCQ2Y +1.0 0 Cushion Rubber bumper (none for CA2Y

Specifications 1-1 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1.0 Mpa Min. operating pressure 0.05Mpa -10 to +70 oC. With magnet built in: -10 to +60 o Ambient and fluid C temperature (No freezing) Lubrication Not required (non-lube) Stroke length tolerance Cushion Air cushion Piston speed 50 to 1000 mm/s Warning Confirm the specifications.

. -10 -20 -30 -40 -50 -60 -70 -80 0 0 to 10 10 to 20 20 to 30 MY3*16/20 Without spacer Short spacer Long spacer 0 to 12 12 to 24 24 to 36 MY3*25/32 Without spacer Short spacer Long spacer 0 to 16 16 to 32 32 to 48 MY3*40/50 Without spacer Short spacer Long spacer 0 to 24 MY3*63 24 to 48 48 to 72 Without spacer Short spacer Long spacer Table 1 Stroke adjustment range (Without spacer, with