Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), RELAY OUTPUT MODULE, VALVE, SV1000 SOLENOID VALVE, 5-PORT, 21, SV1000 NO SIZE RATING, .09900 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation, U-SIDE ENDPLATE, VALVE, SS5V3 MANIFOLD SV3000, 21, SS5V3 NO SIZE RATING, .41580 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation, SUP/EXH Block Assy INT, VALVE, SS5V4 MANIFOLD SV4000, 21, SS5V4 NO SIZE RATING, 0.4741 lb

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 33 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), SUP/EXH Block Assy INT, VALVE, SS5V2 MANIFOLD SV2000, 21, SS5V2 NO SIZE RATING, .40361 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation, PHCS, M4X0.7X15, VALVE, SY3000 SOL/VALVE, RUBBER SEAL, 21, SY NO SIZE RATING, .01254 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation, SUP/EXH Block Assy EXT, VALVE, SS5V4 MANIFOLD SV4000, 21, SS5V4 NO SIZE RATING, 0.6974 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation, AC OUTPUT MANIFOLD MODULE, VALVE, SS5V3 MANIFOLD SV3000, 21, SS5V3 NO SIZE RATING, .20515 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Fluid: air, Operating pressure range: -100kPa to 0.7MPa, Response time ms (at 0.5MPa): 18 or less, Coil rated voltage: 12, 24VDC, Ambient and fluid temperature: -10 to 50 C, Enclosure: IP67 (based on IEC529), INTERFACE REG, W/ METRIC GAUGE, VALVE, SS5V1 MANIFOLD SV1000, 22, SS5V1 NO SIZE RATING, .11440

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation, INTERFACE REG, W/ METRIC GAUGE, VALVE, SS5V3 MANIFOLD SV3000, 22, SS5V3 NO SIZE RATING, .24200 lb

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

The use of 34 pin connectors allows up to 16 stations with double solenoids.SV4000 series valve, Single, double solenoid and 3 position available, Service life: 50 million cycles or more, Supply pressure: 0.5MPa, Unrestricted mounting orientation, SILENCER COVER, VALVE, SS5V3 MANIFOLD SV3000, 21, SS5V3 NO SIZE RATING, .04620 lb

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 34 lb

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 34 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Plug-in connector connecting base , Side ported , Available with external pilot , One-touch fittings , Applicable Fieldbus protocols: DeviceNetĂ–, PROFIBUS DP, CC-Link, EtheNet/IPĂ–, EtherCAT, SS5V 14 Station Manifold, Tie-Rod Base, 4/5 PORT SOLENOID VALVE, VVM, 0.97 lb

The use of 34 pin connectors allows up to 16 stations with double solenoids.Decentralized serial wiring, Tie rod base, 3000 series, IP67 protection, Number of outputs: 16, Maximum number of stations: 16 (over 8 requires manifold spec. form), SS5V 06 Station Manifold, Tie-Rod Base, 4/5 PORT SOLENOID VALVE, VVM, 0.77 lb