Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 09 [
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric
Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 6 (12 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting
Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6
Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (
Note 2: For guidance on the Fluorocarbon Emission Control Law, please visit our website below. https://www.smcworld.com/products/ja/freon/ 7.2 Refrigerant and GWP value IDF60/70/80/90 Series 7-2 J N M L O K H IDX-OM-V022 Chapter 7 Documents 7.3 Dimensions Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J Unit: mm M N O L K H Unit: mm Model Port Size A B C D
H IDX-OM-W093 7.3 Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J M N O L K H mm A B C D E F G H J K L M N O P IDF60 R1 307 745 605 161 405 681 71 330 704 355 126 46 12. 94 5 IDF70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDF80 R2 438 957 863 169 480 958 219 78 100 11. 0 463 916 485 170 IDF90 13 IDF80 IDF90 mm IDF60 745 957 () () 704 916 () 355
(mg/L) 1.0 or less 0.1 or less 1.0 or less Residual chloride (mg/L) 0.3 or less 0.3 or less 0.3 or less Free carbon dioxide (mg/L) 4.0 or less 4.0 or less 4.0 or less Stability index 6.0 to 7.0 or less Water quality inspection (Once a month) If tap water or ground water (well water) is used as the cooling water for the water-cooled condenser, test the items shown in Table 2 using JIS K
H IDX-OM-V020 Chapter 7 Documents 7.3 Dimensions Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J Unit: mm M N O L K H Unit: mm Model Port Size A B C D E F G H J K L M [N] O P IDFA60 R1 307 745 605 161 405 681 71 330 704 355 126 94 46 12.5 IDFA70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDFA80 R2 438 957 863 169 480 958 219 78 100 11.0 463 916 485
H IDX-OM-V024 Chapter 7 Documents 7.3 Dimensions Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J Unit: mm M N O L K H Power cable entry [IDFB60-11: Power cord with plug, length 110(2800)] Unit :inch (mm) Model Port Size A B C D E F G H J K L M N O P 12.1 29.3 23.8 6.3 15.9 26.8 2.8 13.0 27.7 14.0 5.0 IDFB60 R1 (307) (745) (605) (161) (405) (681) 3.7 (71) 1.8
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.
12 32.5 83 13 13 30 NCM 40 13 16 13 63 21 24 G 1/8 10 52 104 52.5 12 38 91 14 16.5 35 50 16 20 14 75 29 32 G 1/4 11.5 65 120.5 58.5 15 46.5 104.5 15.5 19 40 NCA 63 16 20 14 90 29 32 G 1/4 17.5 75 134.5 68 12 56.5 119.5 16.5 23 45 80 21 25 20 102 37 40 G 1/4 22 95 169 81 18 72 150 19 33 45 D100 21 30 20 116 37 40 G 1/4 25 114 189 96 20 89 170 19 37.5 55 T ZZ GE GF J MB K N S V GR MM P Q H
When ordering mixed wiring, please add the option symbol -K.
U Min. bending radius of lead wire 10 Auto switch K M E J S B + Stroke L + Stroke L A + 2 strokes Note) The drawings above show type D-A7 and D-A8 reed switches. The values shown inside ( ) are for switches other than types D-A7 and D-A8. S and U dimensions for connector type auto switches (D-A7C, D-A80C, and D-J79C) are 7mm greater.
Release piston seal NBR M(D)LUB40, 50 Lead-bronze casting 14 Scraper Hexagon socket head cap bolt A NBR Stainless steel Bumper Urethane rubber 4 Series MLU Dimensions Standard type M(D)LUB40, 50 Rod end female thread Retraction locking GA1 Unlocks when pressurized BP unlocking port Front cylinder port P GC1 MM1 KA (manual unlocking unit) Dust cover NH1 M(D)LUB25,32 (Extension locking) K
through 8-L counter bore 4-K through C B + Stroke J J 8-L counter bore A + Stroke M M CHKDB20 & 25 CHKDB32 to 100 Width across flats f c a b g e h + Stroke Rod end male thread (mm) F L A B C D E G H J K M P Q R Bore size (mm) 20 M8 x 1.25 9.5 depth 5.4 51 43 8 12 10 10 6 30 5.5 43 1/8 16.5 6 25 M10 x 1.5 9.5 depth 5.4 53 45 8 14 12 12 6 36 5.5 49 1/8 17 8 32 M12 x 1.75 11 depth 6.5 61 51