Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH FOR AIR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 11.15171 lb
Compact and light weight., Digital 2 color indication., Elbow piping can be used., Integrated flow adjustment valve., Several combinations are possible., Different mounting methods are possible., DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 1.10231 lb
Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 0.92574 lb
Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH FOR AIR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, 11.15171 lb
DB Dynamic brake This device is necessary to use an external dynamic brake. This can be used by setting parameters. interlock When servo-on turns on and operation is available, this signal turns on. RD Ready INP In-position This signal turns on when the accumulated pulse is within the setting range.
) The speed command to be given to the motor is displayed. 0.1r/min (Note 1) 23 Torque command Control the torque at the torque control or stopper control. 0.1% (Note 1) 24 Speed limit Control the speed at the torque control or stopper control. 1r/min (Note 1) Digital waveforms CSON, PC, EMG, EM1, CDP, CSV3 (Note 1), D1, D2, D3, D4 (Note 2) RD, SA, ZSP, TLC, VLC, INP, WNG, ALM, OP, MBR, DB
Pn001.0 is factory-set to stop the servomotor by applying the DB. Gr.2: The servomotor is stopped according to the setting in Pn00B.1 if an alarm occurs. Pn00B.1 is factory-set to stop the servomotor by setting the speed reference to "0." The servomotor under torque control will always use the Gr.1 method to stop.
Pn001.0 is factory-set to stop the servomotor by applying the DB. Gr.2: The servomotor is stopped according to the setting in Pn00B.1 if an alarm occurs. Pn00B.1 is factory-set to stop the servomotor by setting the speed reference to "0." The servomotor under torque control will always use the Gr.1 method to stop.
Noise Level (Reference values) Note 9) 10) Model ZKJ07 ZKJ10 ZKJ12 ZKJ15 Noise level[dB(A)] 52 63 67 71 Note 9) Values are at the standard supply pressure. Note 10) Values are with 1 ejector generating vacuum pressure adequately for adsorption with high-noise reduction silencer (Not guaranteed values).
pressure [kPa] Note 1) -80 Max.suction flow[L/min (ANR) ] Note 1) 5 10 22 Air consumption [L/min (ANR) ] Note 1) 15 25 47 Vacuum Supply pressure supply (PV) port 0.3 to 0.5 pressure range [MPa] Release pressure supply port (PD port) Note 2) 0 to 0.5 Maximum supply pressure [MPa] 0.75 Number of Manifold Stations that Can Operate Simultaneously 8 6 4 Single unit 65 68 70 Noise Level Manifold [dB
No.ZQ-OM01401-B 8.6 1 2 32 4 5kPa ( ) 5 6) 7 31 - No.ZQ-OM01401-B 9. 9.1 ZQA [] 5 to 50 () 2] 1) 20 [m/s 2] 2) 100 [m/s CE / UKCA (EMC RoHS ) 1) 10~150Hz X,Y,Z 2 () 2) X,Y,Z 3 () ZQ05A ZQ07A ZQ10A [mm] 0.5 0.7 1.0 [MPa] 0.35 0.43 1) -80 [kPa] 1) 5 10 22 [L/min (ANR) ] 1) 15 25 47 [L/min (ANR) ] (P) 0.3 to 0.5 2) 0 to 0.45 3) [MPa] (PD) [MPa] 0.75 8 6 4 65 68 70 4) () 64 66 68 [dB
5-1 5 1 IDX-OM-W017 5 () 60cm 1 2 INOUT INOUT () IDFA Series 5-1 5 2 IDX-OM-W017 6 6 6-1 IDFA3E IDFA4E IDFA6E IDFA8E IDFA11E IDFA15E1 3 12 24 36 65 80 120 7 15 31 46 83 101 152 3/h m (ANR)1 10 17 34 50 91 112 168 MPa 0.7 oC 35 oC 25 230V 50Hz oC 550 MPa 0.15 MPa 1.0 oC 24085% 1 AC230V10% 50Hz 4 2 A 1.2 1.2 1.2 1.4 2.7 2.9 2 W 180 180 180 208 385 420 3 A 5 10 50 dB
(BUS OUT and PCI) -17No.EX-OMN0034-B Mounting and Installation Wiring Connector pin assignment and circuit diagram Connector pin assignment Configuration Pin number Signal name BUS IN BUS OUT 1 SLD 2 DB 3 DG 4 DA 5 NC Circuit diagram The product has T branching internally in the unit as shown in the circuit diagram below. It can be extended by connecting the CC-Link slave with BUS OUT.
number 2.00 2.00 2.00 2.00 1.10 1.10 1.10 1.10 64 1 : 8 7 9 6 Number of occupied nodes x10 x1 0 5 4 4 Pin number 1 Address 2 3 5 3 1 4 2 3 2 1 1 4 3 2 1 (2) (3) Content 8 7 9 6 6 Number of occupied nodes SI unit output data size 4 byte (Default setting) 0 5 4 1 2 3 Signal name Bit area input/output 640/640 384/384 128/128 128/128 64/64 96/96 64/64 32/32 SLD 1 byte 2 byte 3 byte DG NC DA DB
Signal name M12, 8pins, Socket, X-Coded (CAT6A) 1 DA+ 2 DA3 DB+ 4 DB5 DD+ 6 DD7 DC8 DC+ Precautions for handling Be sure to fit a seal cap on any unused connectors. Proper use of the seal cap enables the enclosure to achieve IP67 specification. Setting and Adjustment Switch setting STATION NO.
Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, LG BORE, DB *LQA, ACTUATOR, NCQ2 COMPACT CYLINDER, TX, 125MM NCDQ2 DBL ROD/AUTO-SW, 18.70000 lb
Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, LG BORE, DB *LQA, ACTUATOR, NCQ2 COMPACT CYLINDER, VX, 160MM NCQ2 DBL ROD/AUTO-SW, .00000 lb
Please contact us for the latest version.sales@ocaire.com, FILTER PT W/A-DRAIN, AIRLINE EQUIPMENT, AF FILTER, DB, AF 1/4INCH STANDARD (PT), .92400 lb
Please contact us for the latest version.sales@ocaire.com, MUFFLER 1/8 PT, AIRLINE EQUIPMENT, AN SILENCER, CB, AN 1/8INCH, .00220 lb, Model SpecificationsPort size (1)Noise reduction (dB (A))FluidMax. operating pressure (2)Ambient and fluid temperatureEffective area (mm2)Weight (g)Dimensions (mm)ABAN101-01R1 816Compressed air1.0 MPa5 to 150C (3)209.522.511
This is a legacy product, and replaced byAN20-02, MUFFLER POLY 1/4 PT *LQA, AIRLINE EQUIPMENT, AN SILENCER, DB, AN 1/4INCH STANDARD (PT), .03520 lb