Body Size: 30, Thread: F (G), Port: 02 (1/4), Option: CE (C + E), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 02 (Body Ported 1/4), Thread: T (NPTF)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: WO (M8 Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 2 (200VAC 50/60HZ), Electrical Entry: G (Grommet Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: Rc (or None
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: T (NPTF
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: F (G
Body Size: 30, Thread: N (NPT), Port: 02 (1/4), Option: DE1 (D + E1), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: ZA (Digital Pressure Switch: With Unit Conversion Function)
Body Size: 30A, Thread: N (NPT), Port Size: 02 (1/4), Option: Standard, Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: NRZ (N + R + Z)
Body Size: 40, Thread: N (NPT), Port Size: 02 (1/4), Option: D (N.O., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Actuation: 2 (2 Position Double), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected, Sub-plate: 02 (1/4 Port Size), Thread: T (NPTF)
Body Size: 40, Thread: N (NPT), Port Size: 02 (1/4), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: BC (B + C), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: SV (S + V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: RZ (R + Z)
Body Size: 30, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 02 (1/4), Option: BD (B + D), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: CE (C + E), Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: RZ (R + Z)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 02 (