Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2I, VFS5000, 1.606 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, RI, VFS5000 BASE MT 1/2, 4.29901 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, SI, VFS5000 BASE MT 3/4, 5.07063 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, 2I, VFS5000, 2.85344 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, SI, VFS5000 BASE MT 3/4, 6.44483 lb
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUGIN BASE MT, VALVE, VFS5000 SOL VALVE 4/5 PORT, RI, VFS5000 BASE MT 1/2, 5.71312 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, ENDPLATE ASSY (NARM2500), AIRLINE EQUIPMENT, ARM NO SIZE RAPART, .28600 lb
The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1X, ZSE40/50/60 OTHER SIZE RATING, .17416 lb, ModelRated
The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1X, ZSE40/50/60 OTHER SIZE RATING, .17416 lb, ModelRated pressure
Please contact us for the latest version.sales@ocaire.com, VACUUM SWITCH, HIGH PRECISION, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1X, ZSE40/50/60 OTHER SIZE RATING, .44000 lb
Please contact us for the latest version.sales@ocaire.com, VACUUM SWITCH, HIGH PRECISION, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1X, ZSE40/50/60 OTHER SIZE RATING, .40700 lb
Please contact us for the latest version.sales@ocaire.com, VACUUM SWITCH, HIGH PRECISION, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .26400 lb
Please contact us for the latest version.sales@ocaire.com, VACUUM SWITCH, HIGH PRECISION, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .27134 lb
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KX, ZSE40/50/60 1/4 PORTED, .66138 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KX, ZSE40/50/60 1/4 PORTED, .43671 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JC, ZSE40/50/60 1/8 PORTED, .66138 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JC, ZSE40/50/60 1/8 PORTED, .38748 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KC, ZSE40/50/60 1/4 PORTED, .40863 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KD, ZSE40/50/60 1/4 PORTED, .22046 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
Please contact us for the latest version.sales@ocaire.com, SWITCH ASSEMBLY, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KD, ZSE40/50/60 1/4 PORTED, .22046 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay