Body Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to 14.6 (0 to -101) kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06
Nozzle Diameter: 07 (0.7), Body Type: 3M (for Manifold), Solenoid Valve Combination: K1 (Supply Valve: N.C., Release Valve: N.C.), Voltage: 5 (24 VDC), Electrical Entry: LO [L Plug Connector (w/o Connector), w/Light/Surge Voltage Suppressor}, Manual Override: Non-locking, Push Type, Vacuum Pressure Switch Suction Filter: VA (-100 to 100; NPN 1 Output + Energy Saving Function), Unit: M (SI
2 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 65 54 53 27.2 24.2 24 19.7 17.7 17.5 " " 15.2 18.5 21.7 14.4 15.5 50 15 12.5 22.5 26 48 12.8 8.5 52 57 64.5 28 30 34 9.5 11 13.5 24.5 27 30.5 13.5 14.5 16.5 16 17 21.5 61 65 81 17.5 21.5 25.6 16.6 18 23 70 87.5 30.2 34 21.7 24 280
Body Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve/Release Valve: K (N.C. / N.C.), Pressure Sensor/Digital Pressure Switch for Vacuum Spec: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Spec: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port:
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port:
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port:
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 06 [ø6 One-touch Fitting (
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08