SMC Corporation of America
Elite Part Number Search
Search Results "PVQ13-6L-06-M5-A"

Energy saving has also been considered as individual valves can be ordered with a power saving circuit as each valve can be manually turned off, safe maintenance is guaranteed.Individual wiring manifold, Direct mounting and Bracket Mounting, MANIFOLD, VALVE, SS3Y1 MANIFOLD SY100, AJ, SS3Y1 BODY PORT < M5, .12597 lb

Lightweight, compact, and precision control make these speed controls the right choice for many heavy-duty applications. These speed controls are offered with in-line and elbow construction to give the widest choice to your unique application. Locking nuts are included as standard as well as simplified mounting. Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric

x 0.8 thread depth 4 (Piping port) OUT IN Steel balls 12 Series CXSJ Dimensions: 15 to 32 Standard Piping U Q R T ZZ + Stroke Stroke J K SS + Stroke 1 D B M L Z I 1 G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-Rc1/8 thread depth 5 SS T Bore size (mm) 2 2-4.3 through

hole & Double end tapped): MQQTB 10, 16, 20 H effective thread depth C 2-M5 x 0.8 2 x 4-OA effective depth RA 2 x 4-OB Depth of counterbore RB F Q Y I 4-N through 0.2 D E M L B + Stroke K 0.2 A + Stroke M E 25, 30, 40 H effective thread depth C 2-Rc1/8 (NPT1/8, G1/8) F Q Y 2 x 4-OB Depth of counterbore RB 2 x 4-OA effective depth RA J I 4-N through 0.2 D W E M K L B + Stroke 0.2 A + Stroke

L1 L2 A (2) L3 H (1) T2 T1 D1 D2 Model ASR ASQ AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS120-M5 M5 x 0.8 M5 x 0.8 8 10 28.3 10.3 9 9 25 22.2 25.5 AS120-U10/32 10-32UNF 10-32UNF AS220-01 30.5 13.2 14.3 14.6 32.4 27.4 12 (12.7) 18 35.5 1/8 1/8 AS220-02 35.3 17.5 18 19.5 34.8 29.8 17 (17.5) 27.2 40.3 1/4 1/4 AS320-03 40.8 19.7 22.5 24.3 40.6 35.6 19 30 45.8 3/8 3/8 AS420

This product should not be used as a stopper.

x 0.8, NPTF 1/8, M5 x 0.8 Port size R 1/8, M5 x 0.8 NPTF 1/8, M5 x 0.8 ZX ejector mounted type: M5 x 0.8 Enclosure IP40 Note 1) Instant pressure supply of 0.5 MPa has no influence on the switch.

L1 L2 A(2) L3 H(1) T2 T1 D1 D2 Model AS1200-M3 M3 x 0.5 M3 x 0.5 4.5 6.6 23.5 21.5 8 5 5 20.5 18.5 AS1200-M5 M5 x 0.8 M5 x 0.8 25.5 8 10 28.3 10.3 9 9 25 22.2 AS1200-U10/32 10-32 UNF 10-32 UNF AS220-01 27.4 32.4 14.6 14.3 14.1 31.4 36.4 18 12 (12.7) 1/8 1/8 AS220-02 29.8 34.8 19.5 18 18 35.8 40.8 27.2 17 (17.5) 1/4 1/4 AS320-03 35.6 40.6 24.3 22.5 20.8 41.9 46.9 30 19 3/8 3/8 AS420-04 42.4

Please consult SMC when considering the necessity of the regeneration option. 200 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a Mep L1 (mm) L2 (mm) L3 (mm) Pitching Rolling Yawing 100 m a=1000 a=2000 a=3000 L1 0 30 20 10 Transfer load m (kg) Maximum load L2 200 a=3000 Regeneration option model Driver type Mer a=2000 A1 A2 B1 B2 a=1000 Not required. Not required.

A Unused A Unused A Unused A Unused A Unused A B A B A B A B A B A A A B A B A B A A A A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 6 7 8 9 10 11 12 13 14 15 0 0 1 2 3 4 5 Type SC OMRON Corporation SYSBUS Wire System Type SD SHARP Corporation Satellite I/O Link System ADDRESS NO. STATION NO.

Series IDG<A Purge air flow reduction type A white body is introduced.

Be certain to adopt a reliable connecting method if the rotary table is used very frequently or if it is used in a location that is exposed to a large amount of vibrations. 5. There may be cases in which a speed reduction circuit or a shock absorber is required.

B A A B B-B In-line motor Component Parts Component Parts (Top/Right/Left side parallel only) No.

If driving a load such as a relay that generates a surge voltage, use a contact protection box. Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly.

Do not apply a lateral load to the external slider. When a load is mounted directly to the cylinder, variations in the alignment of each shaft center cannot be offset, which results in the generation of a lateral load that can cause malfunction.

M5 x 0.8 (with plug) [PS pressure detection port] U side D side (L4) L3 43.5 (9.1) When slotted locking needle type is selected. 8 1 When manual needle type is selected. 5.5 20.8 56.2 56.2 25 10 (3) (3) 35 17.2 19.3 90.7 PE X DIN rail B A B A B A B A B A 9.9 Manual override (Locking type: Press, then rotate.) 4(A) port side: Blue 2(B) port side: Yellow 30.6 Approx. 300 (Lead wire length)

N T-slot for body mounting Z + stroke (mm) P M5 x 0.8 1/8 1/4 MM M4 x 0.7 M5 x 0.8 M6 x 1 L 80 110.8 180 LD 3.4 5.5 9 LB 50.4 71.7 80.3 LA 70 100 158 J M3 x 0.5 M5 x 0.8 M6 x 1 H 28 37 58 GB 17 19.5 31.5 G 8.5 10.7 15.5 N 20 25 40 C 3.3 5.4 32.5 M 7 9 13 B 6.5 9.5 14 LW 83 123 161 A 80 105 165 (LL) 40 49.6 75 LE 4 5 6 NC 14 21.3 32.4 NT 3.5 5.3 6.5 NE 27 35.5 56.5 NH 2 3 4 NX 5.8 8.5 10.5

Please contact SMC when the AC welding current exceeds 16000 A.

PFMV5 series recommended fitting list One-Touch fitting/Series KQ2 Type Tube dimension mm Port size Model Male Connector KQ2H04-M5 4 M5 x 0.8 Hexagon socket head male connector KQ2S04-M5 Male elboe KQ2L04-M5 One-Touch mini/Series KJ Type Tube dimension mm Port size Model Male Connector KJH04-M5 Hexagon socket head male connector KJS04-M5 4 M5 x 0.8 Male elboe KJL04-M5 Miniature fitting/Series

Port size Port size Rc, NPT, TSJ, UOJ Female thread 1/4 M5 02 M5 Symbol Connection Bracket is included as a standard.