VQZ2000-SVQZ2000 (1) (1) VQZ3000-SVQZ3000 (2) (2) (2) Coil voltage (2) 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC Others 1 2 3 4 5 6 9 Note 1) L, LO, M and MO types are attached with light and surge voltage suppressors as standard. Note 2) DIN style is applicable to VQZ2000, 3000.
Example) S2S2: Standard cable (2 m) + Driver (LECSS2) S2 : Standard cable (2 m) Nil : Without cable and driver * Please consult with SMC for non-standard strokes as they are produced as special orders. * Specifications and dimensions for the 25A-series are the same as standard products.
Conditions Body ported Tube bore x Length Speed controller Silencer Series CJ2 Series CM2 6 x 1 m AS3301F-06 12 x 1 m AS4001F-12 AN200-02 Series MB 6 x 1 m AS2301F-06 AN110-01 VZ5120-01 3-3-55 Series VZ5000 Construction 2 position single 2 position double De-energized De-energized 3 position closed center/exhaust center/pressure center 3 position closed center De-energized De-energized 3
15 to 32 Standard Piping U Q R T ZZ + Stroke Stroke J K SS + Stroke 1 D B M L Z I 1 G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-Rc1/8 thread depth 5 SS T Bore size (mm) 2 2-4.3 through 2 2-8 counterbore with depth 4.3 2 2-5.5 through 2 2-9.5 counterbore with
8 (Metric) 04 2 x Rc1/2 (Branch specification) F06 G3/4*2 *3 The same thread type selected for e is used for the port. t Supply valve/Release valve combination u Electrical entry F04 2 x G1/2*2 (Branch specification) N06 NPT3/4 5/16" (Inch) N04 2 x NPT1/2 (Branch specification) L plug connector M plug connector L: Lead wire length 0.3 m M: Lead wire length 0.3 m K1 Supply valve (N.C.),
Y7BWV Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Relay, PLC IC circuit 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil(Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since there are other
Grommet T79 2-wire 12V Connector T79C S79 3-wire (NPN) IC circuit Grommet 5V, 12V Heavy-duty cord 3-wire (PNP) S7P For 20, Relay, PLC D24V 30 and 40 Grommet 100V R73 Connector R73C 2-wire Grommet 48V, 100V IC circuit 100 V or less R80 Connector R80C 24 V or less Lead wire length symbols: 0.5 m Nil (Example) R73C 3 m L (Example) R73CL 5 m Z (Example) R73CZ None N (Example) R73CN 63 Series
EXW1 EXW1 Up to 100 m V.1.0/V.2.0 Available*1 EXW1 EXW1+EX600 *2 V.1.0 NA EXW1 EX600 Up to 10 m V.1.0 NA EX600 EXW1 Up to 10 m V.1.0 NA Available*3 EX600 EXW1+EX600 Up to 10 m V.1.0 NA Available*3 EX600 EX600 Up to 10 m V.1.0 NA Available *1: Available in protocol V.2.0. *2: Up to 100 m between an EXW1 series Base and Remote, and up to 10 m between an EXW1 series Base and an EX600-W series
(R) 2-Applicable tubing 10 41 18.5 29 24 29.4 17 M L1 M L1 17 12 58 20.9 46 25 31.4 22 D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.
(R) 2-Applicable tubing 10 41 18.5 29 24 29.4 17 M L1 M L1 17 12 58 20.9 46 25 31.4 22 D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.
P4DWZ 5 m 2-wire (14) 2-color display P79WSE Pre-wired connector 24 VDC 0.3 m CLK2P series DC / AC magnetic field P74L 3 m Reed switch 24 VDC 100 VAC Grommet (Pre-wired connector) 1-color display 2-wire P74Z 5 m Note 1) PLC: Programmable Logic Controller Note 2) Refer to page 17 when ordering the auto switch mounting bracket assembly or switch mounting rod assembly. 1 Series CLK2G/CLK2P
A96 V V IC circuit 2-wire 24 V 12 V 100 V A93V*2 A93 V V V V Relay, PLC No 100 V or less A90V A90 V V IC circuit *1 Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. *2 1 m type lead wire is only applicable to D-A93. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example
Item Load factor n Note Examine m. mmax is the max. load mass for Va. 1 = m/mmax 1: Maximum load mass Examine M1, M2, M3. Mmax is the allowable moment for Va. 2 = M/Mmax 2: Static moment Examine M1E, M3E.
(R) 2-Applicable tubing 10 41 18.5 29 24 29.4 17 M L1 M L1 17 12 58 20.9 46 25 31.4 22 D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.
tube Piston Piston rod Bushing Lock piston Lock bushing Lock spring Bumper Hexagon socket head cap screw Cap A Cap B Rubber cap M/O knob M/O bolt M/O spring Stopper ring C76 Note No. @2 @3 @4 @5 @6 @7 @8 @9 #0 #1 #2 #3 #4 #5 #6 #7 #8 #9 $0 $1 Note) In the case of cylinders with auto switches, magnets are installed in the piston.
Find the value of m max at 300 mm/s in Graph (6) for m3. m L1 2. Static moment M2 = m x g x L1 = 0.5 x 9.8 x 0.05 = 0.245 [Nm] 2 = M2/M2 max = 0.245/3 = 0.082 Investigate M2. M1 and M3 are not required because they are not generated.
(R) 2-Applicable tubing 10 41 18.5 29 24 29.4 17 M L1 M L1 17 12 58 20.9 46 25 31.4 22 D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.
Panel Display and Sigma Win+TM.2-2 2.1 Panel Display.2-2 2.1.1 Status Display.2-2 2.1.2 Alarm and Warning Display.2-2 2.1.3 Hard Wire Base Block Display.2-2 2.1.4 Overtravel Display.2-2 2.2 SigmaWin+TM.2-3 2.2.1 Compatible Devices.2-3 2.2.2 Hardware requirements.2-3 2.2.3 Installing SigmaWin+TM Program.2-3 2.2.4 Starting SigmaWin+TM.2-12 2.3 Utility Functions.2-15 2.4 Parameters.2-15 2.4.1
2 hrs. each in X, Y directions 4 hrs. in Z direction based upon JIS D 1601 Vibration resistance -XC22 Fluororubber seals 30 G 3 times each in X, Y, Z directions Impact resistance IP-67 (IEC Standard)(2) Enclosure CE1-R 5 m, 10 m, 15 m, 20 m Extension Cable (Option) Note 1) This includes the digital display error of the counter (CEU5).
Operating Parameters Status Gas Operating pressure Proof pressure Burst pressure Ambient and operating temperature Cv Vacuum to 250 psig (1.7 MPa) Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 14 to 160F (10 to 71C) (No freezing) 1) 0.29 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in