(mm) Fitting size D 3.2 4 Weight g B C E F A Model M-32R-2 M-04R-2 36 36.5 31 .5 32 0.9 0.7 0.8 2 x 1 .2 20.5 4 Parts list Note Electroless nickel plated Electroless nickel plated Material Brass Brass PP No. 1 2 3 Description Sleeve Studded body Stem Applicable fitting size D Applicable tubing 3 2 1 C F D E B A 3
Controller (VYU5-D) External appearance of exclusive controller RUN1 STOP START SEL. SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.
type 20-CBM2 End lock type Air cylinder Series M(D)B 20-M(D)B Standard type 20-M(D)BW Double rod type End lock type 20-M(D)BB 6-18-2 3 Copper-free Air Cylinders Air Cylinders Bore size (mm) Series Application 6 8 12 (10) 16 (15) 20 25 32 40 50 63 80 100 125 140 160 Standard Copper-free Series variations Air cylinder Series C(D)A1 20-CA1N Standard type CJ1 20-CA1WN Double rod type CJP 20-
X 13-11-69 2 Series ZPT/ZPX Model Selection A vacuum pad diameter (D) can be determined by calculation if the lifting force needed to perform the work function is known. The weight of the workpiece and any potential dynamic forces involved during movement (lifting, stopping, rotating, etc.) need to be considered.
L/min *7 202 202000 L/min R Rc *7 N NPT F G*1 *1IS0228 5 M SI6 *5: 501 102 202 (SI) 04 1/2 *6:L/min 06 3/4 L 1 *4 (2m) OUT1 OUT2 A NPN NPN B PNP PNP C NPN (15 V) D NPN (420 mA) E*2 PNP (15 V) *4 (2m) F*2 PNP (420 mA) + () G*2 NPN *3 W H*2 PNP *3 *2 *3 N M8 *4 ZS-33-D 2m ZS-33-F ZS-42-C PFMB7501/7102 (3.04 ) ZS-42-D PFMB7202 (3.04 ) -10No.PF-OMP0001CN-F (OUT) (IN) INOUT LCD
Handling Precautions 5 1-2. Installation/Piping 8 1-3. Maintenance 10 2. Application 11 3. Specifications 11 4. How to Order 12 5. Component name and spare parts list 13 6. Troubleshooting 14 7. Assembly and replacement procedure 7-1. Bracket assembly 15 7-2. Auto drain replacement 15 7-3. Element replacement 19 8. Dimensions 20 -2- Doc. no.
6 33 () () 10m DC(-)() * ( ) () CE -7No.PS-OMM0002CN-F 0~50(5) SUS630() SUS304() ( ) * 10~15 15 /1% 1941 LCD * -8No.PS-OMM0002CN-F ISE80 02 N 3 ISE80 -0.11MPa ZSE80 0-101KPa ZSE80F -100100KPa ISE80H -0.12MPa Y K + T + 2 02 R1/4 N02 NPT1/4 F02* G1/4 G01 Rc1/8 A2 URJ1/4 B2 TSJ1/4 A (ZS-24-A/ZS-35-A) B *(ZS-24-D) C D + F02 ISO228-1 1 *1 L M SI*2 P (psi)*1 1 2 ISE80H: MPa
DC24V 24V SY100-61-3-05 N N DC12V 12V SY100-61-3-06 AC100V 100V SY100-61-2-01 D DIN Assy V115-D V115-Y AC200V 200V SY100-61-2-02 AC110V 110V SY100-61-2-03 V111(G,H,L,M,W)V115-Y(DIN) AC220V 220V SY100-61-2-04 Y DIN SY100-82-1 DC24V 24VN SY100-82-3-05 DC12V 12VN SY100-82-3-06 AC100V 100VN SY100-82-2-01 () AC200V 200VN SY100-82-2-02 AC110V(AC115V) 110VN SY100-82-2-03 AC220V(AC230V
Note 2) Refer to page 7 for further information of options.
(mm) Nylon Urethane Effective orifice(mm 2) Weight (g) L A D M Part No. d KCH04-99 KCH06-99 KCH08-99 KCH10-99 KCH12-99 4 6 8 10 12 5 8 11 18 24 5.6 5.6 13.1 13.1 26.1 18.0 41.5 29.5 58.3 46.1 40.6 43.1 46.7 52.6 54.9 22.6 24.1 25.2 28.6 29.4 9.8 11.8 14 17 19 16 17 18.5 21 22 4 6 8 10 12 Note) D: max. diameter 77
RX RX RX RX RX RX RX RX (n+2)8 (n+2)9 (n+2)7 (n+2)6 (n+2)5 (n+2)4 (n+2)3 (n+2)2 Point table No. output 3 (PT2) RX(n+2)4 0 0 0 0 0 0 1 0 1 1 0 0 0 0 0 2 0 0 Point table No. output 4 (PT3) RX(n+2)5 1 1 0 0 0 0 0 3 0 0 1 4 0 0 0 0 0 0 Point table No. output 5 (PT4) RX(n+2)6 Point table No. output 6 (PT5) RX(n+2)7 1 1 1 1 1 254 1 1 0 1 255 1 1 1 1 1 1 1 Point table No. output 7 (PT6) RX(n+2)8
RX RX RX RX RX RX RX RX (n+2)8 (n+2)9 (n+2)7 (n+2)6 (n+2)5 (n+2)4 (n+2)3 (n+2)2 Point table No. output 3 (PT2) RX(n+2)4 0 0 0 0 0 0 1 0 1 1 0 0 0 0 0 2 0 0 Point table No. output 4 (PT3) RX(n+2)5 1 1 0 0 0 0 0 3 0 0 1 4 0 0 0 0 0 0 Point table No. output 5 (PT4) RX(n+2)6 Point table No. output 6 (PT5) RX(n+2)7 1 1 1 1 1 254 1 1 0 1 255 1 1 1 1 1 1 1 Point table No. output 7 (PT6) RX(n+2)8
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-9 Connection of RS-232C 3.3 Installation HRR Series 3-18 HRX-OM-X084 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
Ported Type 21 Manifold Grommet: G DIN terminal: D Manual override (non-locking) 2-Rc(PT) 1/8 (ports P) Applicable cord O.D. 4 to 6.5 78.5 Max .10 71.5 71 Light (DZtype only) 67.5 59 32 17 2 2-4.5 (mounting holes) P 19 35 P Pg.7 2-Rc(PT) 1/8 (ports P) A A A 11 20 26 49 Approx. 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc(PT) 1/8, M5 x 0.8 (port A) 19 35 n-Rc(PT) 1/8 (port
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-O021 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
Model AMD450 AMD550 AMD650 AMD850 AMD150 AMD250 AMD350 Rated flow (l/min (ANR))(1) 2000 3500 6000 12000 200 500 1000 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 31/2, 1 1, 11/2 11/2, 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Standing Style/Model Model AMD1000 Rated flow (l/min(ANR)) 8000 AMD800 24000 AMD900 40 Port size (Nominal size B) 2B Flange 2B
switch circuit D-M9 N L V OUT Black Lead wire length Series Model Number DC(-) Blue Nil L Z 0.5m 3m 5m Wiring and output D-M9B/M9BV N P B 3-wire, NPN 2-wire, PNP 2-wire OUT(+) Brown Electrical entry Nil V In-line Perpendicular OUT(-) Blue 1 Series D-M9 Auto Switch Dimensions D-M9 D-M9V M2.5 x 4l slotted set screw Indicator light 2.6 M2.5 x 4l slotted set screw Indicator light 500(3000)(
D-A9V Solid state switches D-F9 D-F9V 2 color indication solid state D-F9W D-F9WV MXQ 6 MXQL 6 6 MXQ 8 MXQL 8 8 MXQ12 MXQL12 12 MXQ16 MXQL16 16 MXQ20 MXQL20 20 MXQ25 MXQL25 25 Function Options Adjuster Options With Buffer Mechanism With End lock Protects work pieces and tools, etc., by eliminating impact at the end of the extension stroke Buffer unit is auto switch capable Holds