Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: Y (w/o Operation Manual
Size: M5, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory: Panel Mount w/Set Nut, Option 1: 0.02~0.2MPa Setting+Non-relieving, Option 2: Name Plate & Pressure Gauge in Imperial Units, PSI, °F
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: C+G, Attachment: w/o Attachment, Option 1: None, Option 2: None, Option 3: Name Plate, Caution Plate for Bowl, and Pressure Gauge: PSI, °F
Size: M5, Thread: M Thread, Rc(PT), Port Size: M5 x 0.8, Accessory: None, Attachment: w/o Attachment, Option 1: Metal Bowl, Option 2: None, Option 3: Name Plate, Caution Plate for Bowl, and Pressure Gauge: PSI, °F
range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (AC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB
range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (AC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB
range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB
range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB
range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB
range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB
range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB
pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VQZ300 BUILT IN FITTING >1/4, VALVE, VQZ300 VALVE, SOL 3-PORT, WB
range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC), VALVE, VQZ300 VALVE, SOL 3-PORT, WB
inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50C, VALVE, VALVE, VQZ300 VALVE, SOL 3-PORT, WB
range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTER (DC) *LQA, VALVE, VQZ300 VALVE, SOL 3-PORT, WB
Body Style: Plug-in Y, Male Branch Y, Union Y, Tube A: 1/4, Tube B: Not Applicable, Thread-Tube Size: 1/4-18 NPT, Sealant/Body Length: Sealant
Body Style: Plug-in Y, Male Branch Y, Union Y, Tube A: 1/2, Tube B: Not Applicable, Thread-Tube Size: 1/2-14 NPT, Sealant/Body Length: Sealant
Body Style: Plug-in Y, Male Branch Y, Union Y, Tube A: 1/4, Tube B: Not Applicable, Thread-Tube Size: 1/8-27 NPT, Sealant/Body Length: Sealant
Body Style: Plug-in Y, Male Branch Y, Union Y, Tube A: 1/2, Tube B: Not Applicable, Thread-Tube Size: 3/8-18 NPT, Sealant/Body Length: Sealant
Body Style: Plug-in Y, Male Branch Y, Union Y, Tube A: 3/8, Tube B: Not Applicable, Thread-Tube Size: 3/8-18 NPT, Sealant/Body Length: Sealant