Union "Y": KPQU, KPGU D 3 x Applicable tubing Effective area mm2 D Model L1 TPH TPS Note 1) Applicable tubing O.D. mm P Weight g M P Q L2 M L2 L1 4 KPGU04-00 KPQU04-00 17 10.4 7 4 4 9.7 10.4 36.8 19.6 6 KPGU06-00 KPQU06-00 18.5 12.8 10 10 10 11.7 12.8 40.1 21.8 8 8 KPGU08-00 KPQU08-00 20.5 15.2 17 18 26 13.7 15.2 46.7 26.5 4.2 M 10 KPGU10-00 KPQU10-00 23 18.5 26 29 41 16.1 18.5 52 29.7 12
PX Edition C Safety Be sure to read Handling Precautions for SMC Products (M-E03-3) before using. 52 Global Manufacturing, Distribution and Service Network Worldwide Subsidiaries America America North & South America Asia/Oceania Europe/Africa SRI LANKA (Distributor) Electro-Serv(Pvt.)Ltd. CZECH REPUBLIC SMC Industrial Automation CZ s.r.o. U.S.A.
D C B A Gauge port in the outlet side (Pressure gauge) Inlet (mm) Drain port E FGFS5A-60 FGFC5A-60 FGFL5A-60 FGFR5A-60 FGFS5B-60 FGFC5B-60 FGFL5B-60 FGFR5B-60 Model A B C D 25(2B)JIS10KFF O.D608 Outlet 956 1050 1320 1649 1790 150(6B)JIS10KFF 633 25(2B)JIS10KFF 250 1286 1380 1650 1979 2120 Fluid release 370 52 Bag Filter FGF Series Options Companion flange Hexagon bolt and nut Gasket Flange
62 F Differential pressure indicator Blanking cap (65) A 2 x Rc (d) (34) C D C C IN OUT IN IN OUT OUT E (Element removal dimension) Differential pressure indicator Differential pressure indication switch B DRAIN (mm) d A B C D E F Weight (kg) Model FH100-06 FH100-08 FH100-10 FH100-12 FH100-16 FH100-20 FH100-24 3/4 102 90 35 200 290 2.5 1 104 1 1/4 110 100 45 265 380 4.3 1 1/2 144 150 128 52
485 585 685 560 650 750 850 Fixed Connection part dimensions/ Companion flange Female threaded companion flange L-type block companion flange Differential pressure indication switch d Differential pressure indicator d (75) (50) E (Rc) L-type block Y P Z G Q N Y Y (mm) (mm) Port size Weight (kg) d N P Q Y (mm) Port size Weight (kg) d 25 25 25 28 28 28 28 28 Port size Weight (kg) E 47 47 52
When the strainer gauze is clogged : After removing the C-type snap ring (nominal size 52), remove the gauze and clean it. 5.Be sure to connect the nylon tube (T1209) supplied with the product to the OUT side of the liquid collector. If a tube other than the nylon tube supplied with the product is used, this may cause the capability of the liquid collector to lower.
communication connector 10 Product label 272.5 Handle 7 183.6 310 307 126.4 226 73 37.5 0 91 397 Circulating fluid outlet Rc1/2 Bypass valve1 464.6 Cooling fan 424 483 Dustproof filter Drain port (Rc1/4, With cap) 1 Without bypass valve for Option Z (Removed parts) HRR024-A, HRR030-A (86 10) 440 (Includes protruding parts) Ventilation air outlet Ventilation air inlet 2 For Option U: 62 5 550 50 86 52
65 80 120 Outlet air pressure dew point Note 1) IDF IDU Standard condition (ANR) (7C) 15 31 46 83 101 152 Outlet air pressure dew point Air flow capacity m3/h (10C) 17 34 50 91 112 168 Outlet air pressure dew point IDF FS (3C) 13 25 37 68 83 125 Outlet air pressure dew point Note 2) Compressor intake condition (7C) 16 32 48 86 105 158 Outlet air pressure dew point IDFA IDFA (10C) 18 35 52
Fittings & Tubing Air Cylinders Rotary Actuators Lead wire length 300 mm 1(P), 3(R) port 4-Rc1/8 Indicator light 7 2-4.5 (Mounting hole) 57 5.3 5.3 50.5 52 0.6 P 1 R 3 4 4 4 4 4 R 3 P 1 30 17 6.5 15 2 2 2 2 2 8 0.5 0.5 P=11 10 M5: M5 thread 2n-M5 4(A), 2(B) port 4 L2 35 L1 38 42 M plug connector (M) Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches
set screw) 2 x 9.5 counterbore depth 5.3 23 1 500.2 500.2 28 62 53 64 6.3 5 M6 x 1.0 x 18.5 L and M6 x 1.0 11.5 2 x M4 x 0.7 thread depth 6 (Hexagon bolt) (Hexagon nut) 2 x M5 x 0.8 (Through-hole) M6 x 1 x 12 L (Hexagon socket head cap screw) (Z) 8 x M4 x 0.7 thread depth 5.5 (Opposite side: Same) 30 6.5 12.5 7.75 9.5 4 x M5 x 0.8 thread depth 4.5 (Piping port) (Opposite side: Same) 8 10 52
244 157 230 11-LEFG16-S-200 294 207 280 6 2 200 11-LEFG16-S-250 344 257 330 11-LEFG16-S-300 394 307 380 8 3 300 11-LEFG16-S-350 444 357 430 11-LEFG16-S-400 494 407 480 10 4 400 11-LEFG16-S-450 544 457 530 11-LEFG16-S-500 594 507 580 12 5 500 40 11-LEFG25-S 45 64 (102) 3H9 (+0.025 0 ) depth 3 4 x M5 x 0.8 thread depth 8.5 38 50 3.5 3H9 (+0.025 0 ) depth 3 A (Table traveling distance) L 51 (52
The load factor for each direction can be obtained as follows. x = 0/250 = 0 y = 50/180 = 0.27 z = 200/1000 = 0.2 5. x + y + z = 0.47 1 1500 1500 1000 800 1000 1000 Lz 600 L3 [mm] L1 [mm] L2 [mm] 400 500 500 200 Ly Lx 0 10 20 30 40 50 60 0 0 10 20 30 40 50 60 0 0 10 20 30 40 50 60 0 Work load [kg] Work load [kg] Work load [kg] 52 Model Selection LEFS Series AC Servo Motor Clean Room Specification
AFJ40 N T J D M U Bracket (Option) S R C V Q IN OUT 2 x P (Port size) B Clearance for maintenance G A E Model Standard specifications Optional specifications Bracket mount P A B C D E G J M N Q R S T U V AFJ20 1/8, 1/4 40 79.2 9.8 20 25 20 30 27 22 5.4 8.4 40 2.3 28 AFJ30 1/4, 3/8 53 104.1 14 26.7 30 35 26.7 41 35 23 6.5 13 53 2.3 30 AFJ40 1/4, 3/8, 1/2 70 136.1 18 35.4 38.4 40 35.4 50 52
Wetted Parts Material B Brass S 316 SS 316 SS Hastelloy C-22 PCTFE (Option: PTFE) Wetted Parts Body Poppet Diaphragm Seat 52 Series AK1300 Single Stage Regulator for General Applications High flow AZ AK KT BP Diaphragm Valves Check Valves Vacuum Generators Flow Switches Technical Data/ Glossary of Terms Precautions SL AP Recommendations Regulators Dimensions inch (mm) AK1300 2.12 (53.8) Max
NPT 1/2 NPT Accessories Panel Mounting Nut (Optional) AR20P-260S AR30P-260S AR40P-260S Mounting Bracket Kit (Optional) AW20P-270AS-X480 AR30P-270AS-X480 AR40P-270AS-X480 Model AW20 AW30 AW40 Dimensions Refer to drawings on page 7 Standard mm Dimensions Model Port Size C NPT 1/8 NPT 1/8 NPT 1/4 GaugePort D 40 53 70 Q 44 46 54 L 30 41 50 V 55 53 70 J 157(max.160) 218(max.221) 255(max.259) K 52
The set pressure can be adjusted by turning adjustment screw r , which adjusts the spring force. (23) 44 (500) eSwitch assembly rAdjusting screw wRegulating spring qPiston O-ring Adapter 52 Hexagon socket head cap screw Port R1/8 15 23 689
Pressure gauge port size Port size Model AR425/435 AR625/635 AR825/835 AR925/935 1/4, 3/8, 1/2 3/4, 1 1 , 1 2 80 98 126 160 145.5 155 216 241 3 7 5 10 1/4 1/4 1/4 1/4 39.5 43 75 90 50.0 85 48 52 80 90 B24P B25P 67 78 110 140 73 78.5 94.5 4 1 2 1 109.5 680
IN Fitting Type Inch size Metric size ARP Common supply block (S) Common supply block with pressure switch (P) Fitting type Fitting type Straight 6 8 10 8 6 10 Elbow Straight 1/4 5/16 3/8 5/16 1/4 3/8 Elbow Symbol Symbol IR-A 01 02 03 13 14 15 51 52 53 63 64 65 5 56 56 5 IR 0.4 0.2 0.6 0.5 SMC 20 MPa 24 20 17 24 56 IRV 0.3 0.1 VEX 32.5 SRH 4.
Manifold Regulator ARM1000/2000 Series Dimensions 14.5 (With pressure gauge) (Mounting hole) ARJ AR425 to 935 ARX (With pressure gauge) Pressure gauge (Option) AMR ARM ARM Pressure gauge (Option) ARP IR-A IN (Common IN, with plug) IR IRV VEX SRH (Pitch) IN (Individual IN) IN (Common IN) SRP SRF Symbol Model Dimensions ITV C 34 43 D 21 28 E 18 27 F 56 70 G 16 20 H 9 11.5 J 18 24 K 19 28 M 52
IN Fitting Type 15 IR-A Inch size Metric size Straight IN side IN side Symbol Symbol IR Elbow Elbow Straight 1/4 5/16 5/16 1/4 6 8 8 6 IRV 51 52 63 64 01 02 13 14 VEX SRH 3. Tie-rod for Centralized Supply Block Note) SRP Symbol Description Without tie-rod Nil T O-ring SRF With tie-rod Note) The O-ring is attached to the manifold connection. Note) For details, refer to page 705.