Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type), 1st Nominal
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Leadwire: Y (2m Switch/Sensor Only), Unit Options: E (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type Long Lock Nut), 1st Nominal Nozzle
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply Valve
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: BD (with Manifold Options B & D), Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 1 (ø0.7), 1st Selection
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: JK (with Unit Options J & K), 1st Nominal
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: JKW (with Unit Options J, K, & W), 1st
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply Valve and Release Valve: K (N.C.
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 1 (ø0.7), 1st Selection Supply Valve and Release Valve: K (N.C.
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type), 1st Nominal
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Speed Controller with Uni One-touch Fitting AS Series How to Order 2 2 1 U02 06 AS 1F Hexagon lock nut Round lock nut J Nil Lock nut option Body size AS-F AS-F 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard Made to Order TMH X260 Antistatic type Refer to page 635 for details. ASD None Electroless nickel plated N Nil Option AS Type Elbow Universal 2 3 AS-FE Applicable tubing O.D.
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Stations: 08 (Stations), Wiring: F (D-sub Connector), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5
The VZM series is a 5 port mechanical valve. It is compact in design with a large flow capacity (VZM400 Cv 0.55, VZM500 Cv 0.6). The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.55, Port size
The VZM series is a 5 port mechanical valve. It is compact in design with a large flow capacity (VZM400 Cv 0.55, VZM500 Cv 0.6). The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.55, Port size
The VZM series is a 5 port mechanical valve. It is compact in design with a large flow capacity (VZM400 Cv 0.55, VZM500 Cv 0.6). The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.55, Port size
The VZM series is a 5 port mechanical valve. It is compact in design with a large flow capacity (VZM400 Cv 0.55, VZM500 Cv 0.6). The VZM is available in a metal or rubber spool style, with a variety of actuator choices and optional external pilot.Fluid: air, inert gas, Operating pressure: 0.15 to 1.0MPa, Ambient and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.55, Port size