, Z8 D-Y5, Y6, Y7 D-Y7W, D-Y7BAL 180, 200 2 pcs.
6 8 11.5 6.5 32 18.5 13 16 11.5 15 18.5 14.5 13.5 19.5 13.5 8 10 13.5 8.5 40 23 17.5 17 21 19.5 23 24 20 18 19 13.5 15.5 19 14 Auto switch mounting heights (mm) D-C7 D-C8 D-H7 D-H7W D-H7F D-H7BAL D-G39 D-K39 D-A33 D-A34 D-A44 D-B5/B6 D-B59W D-G5NTL D-H7C D-C73C D-C80C Bore size (mm) HS HS HS HS HS 24.5 27.5 27 62 72 20 27 30 29.5 64.5 74.5 25 30.5 33.5 33 68 78 32 40 35 38 37.5 72.5 82.5
Fittings & Tubing Air Cylinders Rotary Actuators 2 x P (Rc, NPT, G) H2 Width across flats B2 2 x NN G Relief port M5 x 0.8 G H1 Width across flats B1 Standard port I Relief port 2 x Eh8 D MM AL A F K NA N N H S + Stroke F ZZ + Stroke (mm) ZZ S P N I E D A 12.5 11 10 10 13 F Bore size Stroke range AL K MM NA NN G H2 41 32 32 26 B2 H H1 22 17 17 13 B1 0 6 6 5 8 8 8 50 45 45 41 200 to 1000 150
Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size
LJ1 60 72 A A Motor mounting area B Section BB When mounting a coupling on the motor, mount it within the dimensional range shown on the left. 9.2 Thread P.C.D. 32.5 Coupling Motor 29.5 30 8 Dimensions D C F D E With brake (mm) 101 8.5 26 32 Without brake (mm) 93 17 19 27.5 E F Coupling mounting dimensions Section AA (Housing interior) Series LJ1H S20 Motor mounting area dimensions Mitsubishi
D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V 20 to 63 B A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-14 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.
L1 D L2 L3 L4 L5 L6 L8 Model Port size AS2000E-01 10 4.5 17 16 5 57 30 61.5 40 15.5 1/8 AS2000E-02 12 4.5 23 20 5 59 30 63.5 40 17 1/4 AS3000E-02, 03 5.5 25 26 5.25 69 45.5 76 56 20.6 13.25 1/4, 3/8 Note 1) Reference dimensions AS4000E 2 x 1/4 to 1/2 72 (Max. 80) (1) Effective thread depth 6 2 x M4 x 0.7 664
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-R016 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.
+ #$ G C D T . %. .* $ %$* / % 0 1* $ %2 2 20 21* +," # $ %&"'(" )* ,# $ %&"'(" )* ++" # $ %&"'(" )* +, #$ 17-3-75 6 The VX series will be revised shortly.
Mounting Position (Detection at Stroke End) and Its Mounting Height D-M9 D-M9W D-M9A D-A9 A 22 [24] (24.5) W B [ ]: Value of the D-M9A ( ): Value of the D-A90/A93 D-M9V D-M9WV D-M9AV D-A9V A 20 (22) W B ( ): Value of the D-M9AV/A9V (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V A 16.5 15.0 22.0 30.0 D-M9A A 16.5 15.0 22.0 30.0 D-M9AV A 16.5 15.0 22.0 30.0 Bore size (mm) 6 10 16 20 B 2.5 7.5
/PL / OSSD SIL 2 2 2 3 3 3 3 3 SIL CL 2 2 2 3 3 3 3 3 * 2 2 4 3 4 ** 4 3 Cat. 3 PL d d d e d e e d *:Cat. 3 EN13849-2 2 N.O. **:Cat. 18 No.EX##-OMY0006CN 3.3.8. SI 0 SI 0 A SI 1. 2.I/O 3.SI 4. 5. 10 0 I/O 0 "0"= SI 72 72 SI 72 SI SI 16 SI SI SI SI 0 16 19 No.EX##-OMY0006CN SI SI SI 16 SI SI 20 D 3.3.9. GSDMLFDCML 3.4.
MK(2) b) Type B mounting (When using the cylinder tube threads) RS Q G RS H A RZQ MI W S CEP1 CE1 CE2 ML2B E t E t C J G5-S Compatible Mounting Bolt Dimensions CV Model Type A mounting Type B mounting E (mm) D: Bolt length (mm) C (mm) Mounting bolt size Mounting bolt size MVGQ MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB28-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB28-D 8 to 11 M3 x
MK(2) b) Type B mounting (When using the cylinder tube threads) RS Q G RS H A RZQ MI W S CEP1 CE1 CE2 ML2B E t E t C J G5-S Compatible Mounting Bolt Dimensions CV Model Type A mounting Type B mounting E (mm) D: Bolt length (mm) C (mm) Mounting bolt size Mounting bolt size MVGQ MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB28-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB28-D 8 to 11 M3 x
(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 1 0 17 1 2 1 18 2 3 2 19 3 4 3 20 4 5 4 21 5 6 5 22 6 7 6 23 ON ON 7 8 7 24 8 9 8 25 1 2 3 4 1 2 3 4 9 10 9 26 A 11 A 27 B 12 B 28 C 13 C 29 D 14 D 30 E 15 E 31 F 16 F 32 -13- Auxiliary axis number Auxiliary axis number Axis selection rotary switch Axis selection rotary switch Control Control setting switch setting switch axis No. axis No.
ZR1D1 D2 D3 10.2 SMC PRESURRE SWITCH RESET SET Attachment D Digital pressure switch Suction filter 71.3 (73.3 for D2, D3 types) 81 SMC 61 PV PD Filter block D 78.8 3 Note) 1 Dimensions for mounting bracket A 2 Dimensions for mounting spacer A Bracket A part no. : P3270153 (Standard accessory) Spacer A part no. : P3270156 13-3-19 19 Series ZR Suction Filter: ZR1-FX Specifications ZR1-FX
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 D VP Color: White VG VP L DIN rail 12.5 (Pitch) 5.25 7.5 AXT100-DR-l VQ Enter suffix the number from DIN rail dimensions table below.
B A (mm) Applicable auto switch D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BA/F7BAV D-F79F Other than the models listed in How to Order, the following auto switches are applicable. For detailed specifications, refer to page 1627.