Do not use valves in such environments where corrosive gases, chemicals, or brine or water or steam is airborne, or where valves can be directly exposed to any of those. 2. Do not use in an explosive environment. 3. Do not use in locations influenced by vibrations or impacts. 4. A protective cover, etc., should be used to shield valves from direct sunlight. 5.
When installing and removing an element, do not scratch or damage it by touching the corners of the case, etc.
: VPA744V(A port) Rc 3/8, 1/2 16 119.5 (PA port) Rc 1/8 16 80 67 (R port) Rc 3/8, 1/2 2(A) NO 53 66 PA 40 3(R) 1(P) NC 2-6.2 (Mounting hole) Switch mark 55.8 52 81.5 82.3 33.5 32.5 24 16 (P port) Rc 3/8, 1/2 5-5-20 9 Series VPA300/500/700 Manifold Specifications How to Order 1 04 41 02 3 VV3PA Thread type SA Nil Rc G NPT NPTF VP Air operated manifold F VA N T SA Body size A port size VV3PA7
16 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 G 5.5 7.5 7.5 8 11 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 H 13 20 20.5 22 29 I 12 15 18 23 J 6 6 8 8 10 K 11 8 10 15 16 L 57 66 70 80 92 P (Piping port) Model Mounting nut/Included in the package (2 pcs).
Note 2) Lead wire entry is inward when the product is shipped. 81 Dual rod cylinder CXSL 1221CXS / 10-/1122Basic style / CXS6, CXSL6 10-/1122122163.5+ST ST 50+ST 8 5.5 16 2-3.4 through 15+1/2ST M3 x 0.5 x 5L 2.75 19 26.5 counter bore depth 3.3 14 1 OUT 3 3 (Hexagon socket head set screw) 1 3.2 5.6 (16) 280.2 280.2 22.7 35 16 37 6.3 5 6 M2.5 x 0.45 x 6L M3 x 0.5 x 12.5L and M3 x 0.5 (Hexagon
30 75 100 " " " " " 7 7 12 16 19 3 16 1 4 1 4 3 8 1 2 Inch size (2) Light and compact molded resin parts Cartridge type allows element replacement Note 1) Flow rate when initial pressure drop is 3 kPa or less.
38 43 81.5 46 52.5 60.5 84.5 87.5 91 D-F7NT 9.5 18.5 22.5 44.5 49.5 47 43.5 50 58 82 85 88.5 D-F9ll 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 D-F9lWl 6 15 19 41 46 43.5 4.4-16
The resulting impact cannot be absorbed easily, the stroke position cannot be maintained, and faulty operation may result. t Lubrication The bearing can be used in an oilless state, but when you are going to oil the bearings, do so by using a ball-cup so that no foreign matter will be mixed.
Refer to pages 16-14-3 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. 9. Wire the microswitch according to the symbols on the upper insulators. (They will be opposite the terminal symbols on the microswitch. The terminals are screw terminals.) 10.
-150 JC63-16-200 8 10 10 12 12 12 16 16 1 1.5 1 1.25 1.5 1.75 1.5 2 D-X Technical Data 1139 JC Series Dimensions of Accessories Rod end nut (mm) d: Thread nominal size Model Order number M8 x 1 M8 x 1.25 M10 x 1 M10 x 1.25 M10 x 1.5 M12 x 1.25 M12 x 1.5 M12 x 1.75 M14 x 1.5 M16 x 1.5 M16 x 2 M18 x 1.5 H 5 5 6 6 6 7 7 7 8 10 10 11 B C 15 15 19.6 19.6 19.6 21.9 21.9 21.9 25.4 27.7 27.7 31.2
When washing the micromesh element, do not wipe it using a stiff brush or rag. 0.03 12 08 20 24 10 16 Pressure drop (MPa) 06 0.01 0.005 COM. N.O.
(mm) Operating pressure range (MPa) Actuation speed (mm/s) MQML Standard type 6(Standard only) 10 16 20 25 6: 0.02 to 0.7 10 to 25: 0.005 to 0.7 0.5 to 1000 5 to 3000 MQMLH High speed/frequency 0.01 to 0.7 NEW NEW Low Friction Cylinder (Single Acting) Series MQP Bore size (mm) 4 6 10 16 20 Operating pressure range (MPa) Thrust control standard (N) Series 0.01 to 8 0.03 to 19 0.08 to 50 0.20
B 35 40.5 QA 6 8 QB 13 16 QV 33 38.5 A 47 58 Bore size (mm) 40 50 21 Adjustable Mounting Height Type Series RSG Rod End Configuration Lever Type with Integrated Shock Absorber Variable energy absorbing type/Flange mounting These drawings (2 items) show the piston rod extended.
Item CH2 measured value: 16-bit signed integer Bit offset 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 Item CH32 measured value: 16-bit signed integer Bit offset 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 Item CH4 measured value: 16-bit signed integer Bit offset 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Error diagnosis CH4 diagnosis CH3 diagnosis CH2 diagnosis CH1 diagnosis Reservation
Consequently, (7) the exhaust valve of (1) the pilot valve moves to the right, the output pressure of OUT1 increases that of OUT2 decreases and (16) the rotary actuator moves.
Do not apply external force to the coil section. When tightening is performed, apply a wrench or other tool to the outside of the piping connection parts. Caution Pilot port piping 12(P1) and 10(P2) piping should be as follows according to the model. 2. Do not warm the coil assembly with a heat insulator, etc. Use tape, heaters, etc., for freeze prevention on the piping and body only.
Fittings & Tubing Air Cylinders Rotary Actuators 63.5+ST ST 50+ST 8 5.5 16 2 x 3.2 through 15+1/2ST 2.75 19 2 x 6.5 counterbore depth 3.3 14 1 OUT 3 3 1 3.2 5.6 (16) 280.2 280.2 22.7 35 16 37 6.3 5 6 M3 x 0.5 x 12.5 L and M3 x 0.5 (Hexagon bolt) (Hexagon nut) 7 2 x M5 x 0.8 thread depth 4.5 IN (Piping port) 2 x M3 x 0.5 (Through-hole) 2 x M3 x 0.5 (Through-hole) 4 x M5 x 0.8 thread depth
Type 16: Cassette Base Manifold. Type 10: Tie-rod Base Manifold. Manifold Option (Common for Type 16 and 10) . Single Valve/Sub-plate Type IP67 Compliant. How to Order . Specifications. Construction. Dimensions . Series SV1000. Series SV2000. Series SV3000. Series SV4000. Made to Order Specifications . Series SZ3000 5 Port Solenoid Valve Rubber Seal, Body Ported Cassette Type Manifold.
Applicable filter model Element size mm Principal Materials ZFC100 12 x 8 x L20 I-62S ZFC101 Description Material ZFC200 16 x 12 x L25 I-63S Case Special transparent nylon ZFC201 Cover PBT Note) When ordering spare elements, enter "-A" at the end of the part number. Spare elements and O-rings for the cover are sold in sets of 10 pieces each.