C): -5~60, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): -, Orifice Diameter(Ø): 16, IP Rating: -, Insulation Class: -, Pipe opening type (details): -, Voltage: -, Sealing materials: NBR, Lead wire exit direction: -, Option: Standard type, Body Material: Bronze, Bracket: Included, Function: None, Lead wire electrical entry: None, Manual operation type: Locking type B
, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): -, Orifice Diameter(Ø): 16, IP Rating: -, Insulation Class: -, Pipe opening type (details): -, Voltage: -, Sealing materials: NBR, Lead wire exit direction: -, Option: Standard type, Body Material: Stainless steel, Bracket: Included, Function: None, Lead wire electrical entry: None, Manual operation type: Locking type B
, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): -, Orifice Diameter(Ø): 16, IP Rating: -, Insulation Class: -, Pipe opening type (details): -, Voltage: -, Sealing materials: FKM, Lead wire exit direction: -, Option: Standard type, Body Material: Stainless steel, Bracket: Included, Function: None, Lead wire electrical entry: None, Manual operation type: Locking type B
, Driving Type: Pilot Type, Operating Pressure Difference Range(MPa): -, Orifice Diameter(Ø): 16, IP Rating: -, Insulation Class: -, Pipe opening type (details): -, Voltage: -, Sealing materials: EPR, Lead wire exit direction: -, Option: Standard type, Body Material: Stainless steel, Bracket: Included, Function: None, Lead wire electrical entry: None, Manual operation type: Locking type B
Size: 4 [ø25(ø16)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: Fluoro Rubber, Thread: NPT, Port Size: 1, Bracket: Bracket
Size: 4 [ø25(ø16)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: Nitrile Rubber, Thread: NPT, Port Size: 1, Bracket: Bracket
Size: 4 (ø25), Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: A (Nitrile Rubber), Thread: N (NPT), Port Size: 25A (1), Bracket: B (Bracket)
Size: 4 [ø25(ø16)], Valve Type: 3 [CO (Operating Pressure 1MPa)], Sealant: B (FKM Seal), Body Material: S (Stainless Steel Body), Pilot System Option: Standard, Thread: N (NPT), Port Size: 25A (1), Bracket: B (Bracket)
Size: 4 [ø25(ø16)], Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: A (NBR Seal), Body Material: Standard (Bronze Body), Pilot System Option: Standard, Thread: N (NPT), Port Size: 25A (1), Bracket: B (Bracket)
Size: 4 [ø25(ø16)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: A (NBR Seal), Body Material: Standard (Bronze Body), Pilot System Option: Standard, Thread: N (NPT), Port Size: 25A (1), Bracket: B (Bracket)
Size: 4 [ø25(ø16)], Valve Type: 2 [NO (Operating Pressure 1MPa)], Sealant: B (FKM Seal), Body Material: S (Stainless Steel Body), Pilot System Option: Standard, Thread: N (NPT), Port Size: 25A (1), Bracket: B (Bracket)
2 i q !1 !4 y !9 !0 u !2 i q !1 !4 y !9 !0 u !3 !2 i q !1 !4 y !9 Open condition Component Parts Note No.
1 r r ASN q q !2 !2 AQ y y ASV !3 w t t AK w i i VCHC o ASR ASQ o !0 e !0 e u u !4 !4 Meter-in type Meter-out type Component Parts Meter-in type Meter-out type No.
How to Order X15 AMG Body size Optional specifications Accessories Thread Port size Dimensions Model Connection A 240 260 300 380 B 256 300 349 496.5 B, FF, 10K 1B, FF, 10K AMG450 AMG550 AMG650 AMG850 3/4 1 1/2 B, FF, 10K 2B, FF, 10K 4.4-6
Note 2) The figure shows an extended piston rod. 7 Heavy Duty Stopper Cylinder Series RSH/RS1H Auto Switch Proper Mounting Position Auto switch B A Auto switch proper mounting position D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W Auto switch models D-Y69 D-Y7PV D-Y7WV D-Y7BAL Bore size (mm) A B A B A B 20 8(6.5) 18 18 9.5 18 2 32 10.5(9) 13.5 13.5 12 13.5 4.5 50 12(10.5) 22 22 13.5 22 6 63 15.5(14) 24.5
-X10 X10 X10 IZS 40 IZS 42 1660 1660 10 10 B B Ordering example) Bar length Type 41 42 520 700 760 880 940 1000 1060 1180 1240 1360 1420 1480 1540 1660 1720 1780 1840 1960 2020 2080 2140 2200 2260 2380 2440 Symbol Specifications Contents Model with drop prevention cover The main unit is shipped fitted with a drop prevention cover available as an option.
Flow Rate Characteristics Operating Frequency Port size Valve flow rate characteristics 70 Ambient and fluid temperatures (Upper limit) [C] 1, 5, 3 (P , EA, EB) 4, 2 (A, B) 1 R 4/2 (P R A/B) 4/2 R 5/3 (A/B R E) Model 60 C [dm3/(sbar)] b C [dm3/(sbar)] b DXT1215 1/8 1/8 1.3 0.37 1.3 0.23 50 Calculation of effective area S and sonic conductance C: S = 5.0 x C 40 30 20 10 0 0 200 Operating
Process valve series VNC, Air operated type, Orifice size: 7mm to 80mm, Port size: 1/8 to 2 Rc(PT), Seal material: NBR, FPM, EPR, VNA/B/C/D, VALVE, VNA/B/C/D 2-WAY MEDIA VALVE, 1C, VNA/B/C/D, 3.69887 lb
Surface B Hexagon socket head set screw Slide table Gasket (apply grease) Replacement shock absorber Guide Cylinder fixing bolts End cover Mounting hole (round hole) Surface B Surface C Surface A Slider Actuator (cylinder) Mounting hole (Oval hole) Enlarged view of end cover Surface A Enlarged view end cover 3. Be sure to fasten the cylinder fixing bolts.
Actuating force F1 is applied to the top surface of pressure regulation piston r by the pilot pressure (pilot valve assembly q: VY1D B 00-00), and actuating force F2 is applied to the bottom surface of the piston by the port A pressure that pases through the feedback passage. Thus, the port A pressure that corresponds to the pilot pressure is established.