Dimensions VP3145-DZA1-X81 (35) Max.10 125.5 87.4 21.5 B A 51 71 80 Manual override (Non-locking) Applicable cable O.D. 4.5 to 7 Pg9 2 x 1/8 (Pilot EXH port) 1/4 (External pilot port) 2 x 8.5 (For mounting) 204.5 195.5 29 PE PA 155 111.5 119 103 93 IN EXH OUT 65 62 42 42 3/8, 1/2, 3/4 (IN, OUT port) 71 36 36 22.6 (Guide) 3/4 (EXH port) In the case of B spec. of -X81 (N.O. spec.), VF3140
Model A B C A B C A B C A B C 500 1000 1500 1000 2200 3000 2000 3300 4000 4000 5700 7000 34.5 38 40 33 36.5 38 34 36 37 34 35 36 35 40 44 35.5 40 42 37 40 41.5 38 40 42 35.5 42.5 47.5 36 42.5 44 38.5 42.5 45 39 43 45 HAA7 HAA15 HAA22 Maintenance HAA37 Caution 1. Inspect the cooler at least once a week and clean it to prevent it from becoming obstructed. 2.
For details, refer to the WEB catalog or Best Pneumatics No. 3. 15-E649 Series MGP Series MGP Dimensions: 12 to 100 With Flange MGPF Flange FC FD H G FF FE 4 x FG through B + Stroke C + Stroke FB FA FH [mm] Bore size B C FA FB FC FD FE FF FG FH G H 12 42 29 7 6 80 89 18 25 4.5 5 26 58 16 46 33 7 6 88 98 22 32 5.5 5 30 64 20 53 37 8 8 102 112 24 38 5.5 6 36 83 25 53.5 37.5 9 7 114 126 30
Switch connection side 0.5m Load connection side 0.5m A 38.5 (1.5) 42 (1.7) B 38.5 (1.5) 42 (1.7) Bore size (mm) 180 200 Dimensions are the same for single rod and double rod. Minimum Strokes for Mounting of Auto Switches Contact protection box internal circuits CD-P11 OUT Brown [Red] Surge absorber Choke coil D-Z7, Z8 D-Y5, Y6, Y7 D-Y7W D-Y7BAL OUT Blue [Black] 180, 200 2 pcs.
Reversed output (out1) 18 - NO. ZQ-OM01501 Function Setting Function selection mode In measurement mode, press the button for 2 seconds or longer to display [F 0]. Select to display the function setting to be changed, [F ]. Press the button for 2 seconds or longer in function selection mode to return to measurement mode.
ZQ-OM01601 // ZQ-ZSV 2 9 10 11 14 14 15 16 16 19 19 19 F0 21 F1 OUT1 22 F2 OUT2 24 F3 26 F4 27 F6 29 F11 30 F80 31 F81 32 F90 33 F96 35 F98 36 F99 38 39 42 43 44 50 51 51 1 - *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.
3 IDFA Series 2 4 IDX-OM-W017 3 / 3 3 1 INOUT 3 2 ON IDFA3E() IDFA4E15E() INOUT 5 ONOFF 0.15MPa NO IN IDFA Series 3-1 3 1 IDX-OM-W017 3 / 3 3 OFF OFF 3 4 3 3 5 3 5 OFF 3 6 24H OFF IDFA Series 3-3 3 2 IDX-OM-W017 4 4 4 1 5 10 4 2 4-2-1 () 4-2-2 1. 100 2 () 100 T 4-2-3 4-1 41 IDFA Series IDX-OM-W017 4 0 OFF 501015 ( 1 OFF IN/OUT 2.3 ) (2 ) () 42
No.PS-OMM0002CN-F / / ZSE80(F) ISE80(H) 2 9 10 11 14 14 16 17 19 19 21 21 21 F0 23 F1 OUT1 24 F2 OUT2 27 F3 27 F4 / 28 F5 30 F7 31 F8 32 F9 34 F10 35 F98 36 F99 38 39 42 42 43 50 50 52 -1No.PS-OMM0002CN-F (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems.
Note 2) Applicable fittings Note 2) 3) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Caution Min. bending radius Min. bending 15 12 23 17 45 34 55 42 65 50 90 70 18 12 27 15 30 23 55 42 65 50 radius mm Note 4) Bending value (Reference) 1. Compatible with water due to a change in materials.
P_3 or n_3 and the set point value light up alternately. 16-2-41 18 Series ZSE 50 60F/ISE 50 60 Setting (Common to ZSE50F/ISE50 and ZSE60F/ISE60) Auto preset (Example: Adsorption Confirmation) 1. Auto preset mode 2. Preparation of auto preset 3. OUT1 auto preset SET Press the SET button. Repeat vacuum and break several times while AIL is displayed.
Manifold 2, 3, 4, 5, 7 1/8, 1/4, (3/8) 17-2-42 VCS20/30/40 Single unit N.C. 2, 3, 4, 5, 7, 10 1/8 to 3/4 0 to 1 (1) 17-2-46 VV2CS2/3/4 N.C. Manifold 2, 3, 4, 5, 7 1/8, 1/4, (3/8) 2 port Direct operated 2, 3, 4, 5, 7, (10) (2) 17-2-52 VCW20/30/40 Single unit N.C./N.O. 1/8 to 3/4 0 to 3 (1) 17-2-57 VV2CW2/3/4 N.C./N.O.
51 53.5 S 51 54 57 57 Q 27 30 32 32 R 40 48 56 58.5 41 50 60 68 64 76 86 91 18 24 30 35 28 34 40 40 11.5 14 15 17.5 15 17 20 20 20.5 25 30 34 12.8 19 23 23 M4 M5 M5 M5 VCA21 VCA31 1/4 1/4, 3/8 3/8, 1/2 3/4 VCA41 4 Series VCA How to Order Manifolds (VCA20) VV2C A 2 02 02 How to Order Manifold Assemblies (Example) Enter the valve and option models to be mounted under the manifold base part
Caution REC25 101110-AS2001F-06-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC32 101110-AS3001F-08-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC40 101110-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 2. Speed control is possible with meter-in and meter-out types of speed controllers.
Ordering Example: VV307-01-052-01-F1 pc. (5 station manifolds base) V0307-1G4 pcs. DXT060-51-13A 1 pc.
SI Unit for VQC/S0700 Series Valves ( EX500-Q 01 ) SI Unit for SV Series Valves ( EX500-S 01 ) M3 28: 4 pcs. ( Plus-minus slot round head screw ) Supply/exhaust block assembly Supply/exhaust block assembly 1.
SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70
GA33-10-01 Outlet pressure (MPa) ARJ AR425 to 935 ARX Width across flats 10 AMR ARM ARM Note 1) in the gauge part no.
jlable 1 7 Not availaHe wih monitor oubut 4 18 Not avaihde wilh pressure range 19'--4O' inM ousril combination noi a\,'aihble {:-_J4"-':
Common dimensions PSE54-IM5 18 3000 13 9.6 8.7 9 4 M5 x 0.8 PSE5401 N01 PSE54-IM5H 8.7 13 3.4 01: R 1/8 N01: NP T1/8 3 8 With across flats 12 M5 x 0.8 7 M5 x 0.8 16-3-26 5 Pressure Sensor For General Fluids Series PSE560 How to Order ZSE ISE Pressure sensing range PSE 0 1 3 4 Positive pressure (0 to 1 MPa) Vacuum (0 to 101 kPa) Compound pressure (100 to 100 kPa) Positive pressure (0 to
(mm) Model CXS10-10 S SS ZZ Z 10 70 87 30 20 80 97 30 30 90 107 40 40 100 117 40 21-/2210-/11-/12CXS10-20 CXS10-30 CXS10-40 CXS10-50 21-/2210-/11-/1221-/2210-/11-/1221-/2210-/11-/1250 110 127 40 21-/2210-/11-/1283 Dual rod cylinder CXSL 1221CXS / 10-/1122Basic style / CXS15, CXSL15 10-/11221221S ZZ SS 20 10 9 2-4.3 through Z 28 counter bore depth 4.4 18 5 30 1 M6 x 1.0 x 5L (Hexagon socket