SMC Corporation of America
Elite Part Number Search
Search Results "RZQA32-200-100-M9NWVSDPC3"

100 100 100 200 200 Vacuum pressure Vacuum pressure Suction flow rate [L/min (ANR)] Air consumption [L/min (ANR)] Suction flow rate [L/min (ANR)] Air consumption [L/min (ANR)] ZK2 80 80 80 80 160 160 Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure [kPa] Air consumption Air consumption ZQ 60 60 60 60 120 120 ZR 40 40 40 40 80 80 Suction flow rate ZB Suction

Symbol Name Initial value Unit PC01 STA Acceleration time constant 0 ms PC02 STB Deceleration time constant 0 ms PC05 SC1 Internal speed command 1 100 r/min PC06 SC2 Internal speed command 2 500 r/min PC07 SC3 Internal speed command 3 1000 r/min PC08 SC4 Internal speed command 4 200 r/min PC09 SC5 Internal speed command 5 300 r/min PC10 SC6 Internal speed command 6 500 r/min PC11 SC7 Internal

Rod end nut 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 Clevis pin 50 Standard Locking release bolt (N type only) 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 Single knuckle joint 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 80 Double knuckle joint (with pin) Option 100 25, 50, 75, 100, 125, 150,

Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube Test conditions G, H type: 6 x 4 tube Reference pressure: 150 kPa : Use within the rated pressure range (100 kPa to 200 kPa). It will be impossible to measure the gap when the operating pressure is less than 80 kPa or more than 220 kPa and the output will be OFF.

N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.

Cutout window View A-A' Mounting Standard Stroke GK BP A AA AB AG AH AI AJ AK AL AM AN AO AP B BZ GC GD Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 11 13 75 32 28 54 134 150 108 140 M 8 135 110 4 9 9 104 86.5 15 16 88 37 29 62 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 15 16 88 37 30 62

) 24 VDC 12 VDC SRP PVQ30 (2.3) SRF 120 ARX20 P = 0.35 MPa 100 P = 0.25 MPa VCHR Flow rate (l/min) 80 P = 0.18 MPa ITV 60 P = 0.1 MPa 40 IC 20 PVQ 0 0 0 20 40 40 80 60 120 80 160 100 200 120 240 140 280 160 320 180 360 200 400 Current (mA) 24 VDC 12 VDC VEF VEP VER PVQ30 (4.0) VEA 120 100 P = 0.12 MPa VY2 Flow rate (l/min) P = 0.08 MPa 80 VBA VBAT P = 0.06 MPa 60 AP100 40 P = 0.04 MPa

Cutout window View A-A' Mounting Standard Stroke GK BP AG AB A AA AN B GD AH AI AJ AK AL AM AO AP BZ GC Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 13 11 54 75 32 28 134 150 108 140 M 8 135 110 4 9 9 104 86.5 16 15 62 88 37 29 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 16 15 62 88 37 30

DGraph (2) Cylinder Output on the Retracting Side (Double acting) 20150 1500 Tube bore size [mm] 100 1000 40 Side load Balance weight 40 50 400 500 32 20 25 30 200 250 300 Operating pressure [MPa] Cylinder output F[N] Load weight [kg] 15 150 Allowable Side Load on the Piston End (Nm) 10 100 Stroke of linear part Size 40 5 10 15 20 25 30 40 50 75 100 4 5 40 50 32 40 14 14 13 13 13 12 12 11

(If m otor option is with lock, lo ck ca ble is also include d.) 200 to 230 LECSC2-S C2 S1 LECSS1S 100 to 120 *6 The standa rd direction of each c a ble is shaft side(A)..

Specification 1.1 AC servo motor 1.1.1 How to order L E J S 100 T9 B 500 T X400 Lead [mm] Motor type Stroke [mm] H 50 200 200 T9 AC servo motor to to A 25 1500 1500 B 10 *Refer to the applicable stroke table.

, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150

CN4 20 - (2) Connection with a PC Controller setting kit Controller 120.3 120.3 mm mm 200 200 mm/s mm/s USB cable (A-miniB type connector) 100 500 100 500 1 1 200 1000 200 1000 2 2 Communication 50 200 50 200 3 3 CN4 cable PC (The PC should be obtained separately.) Caution (1) Do not connect to equipment other than specified (LEC-W1, LEC-W2, LEC-T1, LEC-G).

200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.

Controller CN3 Actuator cable Electric Actuator Motor CN2 5.3 CN4: Serial I/O connector (1) Connection with the teaching box Controller CN4 Teaching box (The 3m cable is provided.) 26 - (2) Connection with a PC Controller setting kit Controller Conversion unit 120.3 120.3 mm mm 200 200 mm/s mm/s USB cable (A-miniB type connector) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200

Rubber seal Exhaust center 10-SQ1431 39 or less 0.19 0.20 0.80 0.15 0.20 0.64 25 or less 100 Rubber seal Pressure center 10-SQ1531 39 or less 0.14 0.20 0.59 0.19 0.21 0.79 25 or less 100 Rubber seal Note 1) Values for the cylinder port size of C6, CYL Values of EXH.

MXH MXH Vertical Horizontal MXS L1: Load eccentricity MXQ m Mounting orientation m MXQ L H MXF L H MXW Maximum speed (mm/s) Up to 100 Up to 300 x Up to 500 Up to 100 100 b 50 v 200 n 50 m Up to 300 100 , 200 .

D X IDK02-100 IDK02-200 IDK04-100 IDK04-200 IDK06-100 IDK06-200 100 200 100 200 100 200 120 220 140 240 140 240 2 x 1.2 D 4 x 2.5 Inner sleeve 6 x 4 Note) Dimensions at 40% relative humidity. Dimensions may change if the relative humidity changes. Made to Order If you require the moisture control tube with an effective length not listed in the above table, please contact SMC. 1

0.01 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L (mm) Overhang L (mm) Overhang L (mm) Graph (6) Load Eccentricity 200 mm Graph (9) Load Eccentricity 200 mm Graph (12) Load Eccentricity 200 mm 1 10 10 0.1 Mass m (kg) 1 1 Mass m (kg) Mass m (kg) 20 16 20 16 10 6 20 16 10 6 0.01 0.1 0.1 10 6 0.01 0.001 0.01 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 Overhang

100 mm Graph (8) Load Eccentricity 100 mm Graph (11) Load Eccentricity 100 mm D1 10 10 -X 0.1 1 Weight m (kg) Weight m (kg) Weight m (kg) 20 16 10 6 201 20 20 16 Data 0.01 0.1 16 10 10 6 6 0.001 0.1 0.01 0 20 40 60 80 100 0 20 40 60 80 100 0 20 40 60 80 100 Overhang L (mm) Overhang L (mm) Overhang L (mm) Graph (12) Load Eccentricity 200 mm Graph (9) Load Eccentricity 200 mm Graph (6) Load