When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or
When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or
Maximum load impedance: Power supply voltage 12V: 300 Power supply voltage 24V: 600 Minimum load impedance: 50 Reduce/Increase supply pressure to within the regulating pressure range. Applied pressure error Brown DC(+) Supply pressure is below the minimum regulating pressure.
700 800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 AU Flow rate (/min (ANR)) Flow rate (/min (ANR)) AF AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ARX21-01 ARX21-02 0.35 0.35 IR 0.30 0.30 Outlet pressure (MPa) Outlet pressure (MPa) VEX 0.25 0.25
Maximum load impedance: Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 Minimum load impedance: 50 Reduce/Increase supply pressure to within the regulating pressure range. Applied pressure error Brown DC(+) Supply pressure is below the minimum regulating pressure.
Filter case Pin Slot Housing Filter element (ZX1-FE) Filter gasket Gasket groove Connector Socket Lead wire Hook 16-7-3 4 Series ZSP1 Dimensions Grommet type: ZSP10X Adjusting needle Pressure sensor Vacuum supply port ADJ 20 Adsorption nozzle port 08 7 48.3 Lead wire length 600 (3000) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650)
First mark the intersection point for a discharge rate of 600 m l/min and a lifting range of 15 m. 2. Find the pilot air pressure for the marked point.
(Type H) VCS 20 1 G Series Lead wire length w 20 30 40 Class 2 Class 3 Class 4 300 mm 600 mm 1000 mm 1500 mm 3000 mm Nil L1 L2 L3 L4 Tilt the screwdriver down in direction q so that the clip slides out in direction w. Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Electrical entry G C T TL Grommet Conduit Conduit terminal Conduit terminal with indicator light Clip part no.
Normally open LVQ Model/Valve Specifications LQ Model AC DC AC DC AC Water Air Max. operating pressure differential (MPa) Oil DC Max. system pressure (MPa) Av x 10 m Cv converted C[dm /(sbar)] b Cv Water, Oil, Steam Flow characteristics Min. operating pressure differential (MPa) Orifice size (mm) Port size Weight (g) Air LVN 2 -6 3 1 4 3 8 1 2 3 4 600 600 850 1370 2.4 2.8 6.0 9.5 0.44 0.42
type Valve Type P Supply Valve E Exhaust Valve Light and Surge Suppressor Nil No light or surge suppressor R With surge suppressor (non-polar) Rated Voltage U With light and surge suppressor (non-polar) 5 24VDC S With surge suppressor 6 12VDC Z With light and surge suppressor V 6VDC U type only available for 12 and 24VDC S 5VDC R 3VDC Electrical Entry G Grommet, 300 mm lead wire H Grommet, 600
S = 38mm VCA21 200 300 400 500 600 700 VCA21 VCA31 VCA31 VCA41 VCA41 VCA41 Other 200 400 400 600 800 1000 1200 1. Material HNBR: Nitrile hydride rubber 500 700 500 1000 1500 800 1000 1200 1000 500 Flow rate Q l/min (ANR) Viewing the graph The sonic range pressure to generate a flow rate of 500l/min (ANR) is P = 0.64MPa for a 3 orifice, and P = 0.35MPa for a 4 orifice.
Cylinder Speed Chart Cv factor Metal seal (Rubber seal) Cylinder bore size mm Cylinder speed mm/s Model 40 50 63 80 100 125 140 160 150 300 1.5 (1.7) VQ7-6 450 600 750 150 300 3.2 (3.2) VQ7-8 450 600 750 Pressure 0.5MPa, Load factor 50% Note) Use as a guide for selection, as cylinder speeds will vary depending on the piping equipment.
(mm) mm Flow rate coefficient Max. system pressure (MPa) (1) Port size Weight (g) Cv Water Air Model AC DC AC DC AC DC Effective area (mm2) 34 10 1.9 600 10 VXZ2232-02 0.7 0.6 0.7 0.6 0.7 0.6 1 4 1 4 10 43 2.4 600 10 VXZ2232-03 0.7 0.6 0.7 0.6 0.7 0.6 3 8 3 8 . 0.7 VXZ2242-04 0 1.5 15 95 5.3 850 15 0.7 0.6 0.7 0.6 0.6 1 2 1 2 165 20 9.2 1,370 20 VXZ2352-06 0.7 0.6 0.7 0.6 0.7 0.6 3 4 3 4