SMC Corporation of America
Elite Part Number Search
Search Results "JJ5SY3-10S6EA4-04F-C6-M"

Series: JSY3000, Type: Side-Ported, Connector Type: D-sub Connector, IP67, 25 Pins, Connector Entry Direction: Upward, Valve Stations: 2 Stations, P,E Port Location: D Side, 2 to 10 Stations, SUP/EXH Block: Internal Pilot, Built-in Silencer, A,B Port Size: ø8 One-touch Fitting, Mounting: Direct Mounting, DIN Rail Option: DIN Rail Mounting, w/DIN Rail, Combination Manifold: Combinaton Manifold

Side-Ported, Serial Interface, EX260), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 5 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting), Mounting: Direct Mounting, DIN Rail Option: DIN Rail Mounting, w/DIN Rail, Combination Manifold: M

Side-Ported, Serial Interface, EX260), SI Unit: KA (IO-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP, Negative Common), Valve Stations: 8 Stations, P,E Port Location: B (Both Sides, 2 to 24 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting), Mounting: Direct Mounting, DIN Rail Option: DIN Rail Mounting, w/DIN Rail, Combination Manifold: M

Lubrication Not required Mounting orientation Unrestricted 300/50 Note 2) Impact/Vibration resistance (m/s2) Note 1) In the case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation.

Lubrication Not required VFA Mounting orientation Unrestricted 300/50 Note 2) Impact/Vibration resistance (m/s2) VFRA Note 1) In case of single type, be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation.

M5: M5 female threads 5-wire oil resistant heavy-duty cord (0.15 mm2) 01/T1 types approx. 60 g, W1 type approx. 80 g, C4/C6/M5 types approx. 92 g (Each including 0.6 m lead wires) Port size Lead wire Weight Note) When equipped with auto shift function, the following ranges can be set.

Note 5) For ZSE40F (compound pressure) with "psi" indication, zero clear is in the range of 0.01 psi. 100.0 to 100.0kPa 100.0 to 100.0kPa 101.3 to 101.3kPa 10.0 to 101.3kPa 0.1 to 1.000MPa 1.000 to 1.000MPa Internal circuits and wiring examples ZSE40 (F) ISE40-m-22 (L)-(M) ZSE40 (F) ISE40-m-62 (L)-(M) DC (+) (Brown) DC (+) (Brown) Analog output (Gray) Analog output (Gray) OUT1 (Black) OUT2

Note 5) For ZSE40F (compound pressure) with "psi" indication, zero clear is in the range of 0.01 psi. 22 62 30 70 Set pressure range 100.0 to 100.0kPa 10.0 to 101.3kPa 0.1 to 1.000MPa Setting range 100.0 to 100.0kPa 101.3 to 101.3kPa 1.000 to 1.000MPa Internal circuits and wiring examples ZSE40 (F) ISE40--62 (L)-(M) ZSE40 (F) ISE40--22 (L)-(M) DC (+) (Brown) DC (+) (Brown) Analog output

Ordering example) Lead wire length 5A 10 ZS ZCU Lead wire length (For DC) Nil 6 10 15 20 25 30 0.3 m (Standard) 4A 20 VJ10 6 AMJ 0.6 m 1 m 1.5 m 2 m 2.5 m 3 m Note) If ordering a vacuum switch with 3 m lead wire, specify both the vacuum unit switch and the 3 m lead wire connector part numbers. Nil 30 50 0.6 m 3 m 5 m (For 100 VAC) 1A 36 VJ10 6 Misc. ZX1051-K15LOZ-EC 1 pc.

Note 2) ( ): Denotes without sub-plate. 5-2-6 5 5 Port Air Operated Valve Series SYA3000/5000/7000 Series SYA3000: Body Ported Foot bracket SYA3120-F1 C4, N3 C6, N7 2 position single SYA3120(-F2) C4, N3 C6, N7 One-touch fitting (A, B port) M5 x 8 (Pilot port) Applicable tubing O.D.: 4, 1/4" 6, 5/32" Manual override (Non-locking) SA VA 2 2.2 (For manifold mounting) SA 2 3.2 (For mounting

Note 2) ( ): denotes without sub-plate. 1731 Series SYA3000/5000/7000 Dimensions/Series SYA3000: Body Ported Foot bracket SYA3120-F1 C4, N3 C6, N7 2 position single SYA3120(-F2) C4, N3 C6, N7 One-touch fitting (A, B port) M5 x 0.8 (Pilot port) Applicable tubing O.D.: 4, 1/4" 6, 5/32" Manual override (Non-locking) 2 x 2.2 (For manifold mounting) 2 x 3.2 (For mounting) (2 x 3.2 for mounting

Note 2) ( ): denotes without sub-plate. 1461 SYA3000/5000/7000 Series Dimensions/SYA3000 Series: Body Ported Foot bracket SYA3120-F1 C4, N3 C6, N7 2 position single SYA3120(-F2) C4, N3 C6, N7 One-touch fitting (A, B port) M5 x 0.8 (Pilot port) Manual override (Non-locking) Applicable tubing O.D.: 4, 1/4" 6, 5/32" 2 x 2.2 (For manifold mounting) 2 x 3.2 (For mounting) (2 x 3.2 for mounting

D-LC05: Lead wire 0.5 m D-LC30: Lead wire 3 m D-LC50: Lead wire 5 m For the applicable auto switch model, refer to the table below. Applicabie Auto Switch/Refer to page 11-1-1 for further information on auto switches.

D-LC05: Lead wire 0.5 m D-LC30: Lead wire 3 m D-LC50: Lead wire 5 m For the applicable auto switch model, refer to the table below. Applicabie Auto Switch/Refer to page 11-1-1 for further information on auto switches.

D-LC05: Lead wire 0.5 m D-LC30: Lead wire 3 m D-LC50: Lead wire 5 m For the applicable auto switch model, refer to the table below. Applicabie Auto Switch/Refer to page 11-1-1 for further information on auto switches.

Size 4 6 5/32 1/4 Size 6 8 1/4 5/16 Symbol C4 C6 N3 N7 Symbol C6 C8 N7 N9 Straight type Elbow type Straight type Elbow type V R W X S T Y U One-touch fittings for regulator block One-touch fittings for centralized supply block Fitting size Elbow W Elbow X Elbow Y Straight V Fitting size Elbow S Elbow T Elbow U Straight R 4, 5/32 2.5 6 11 35.5 4, 5/32 6 3 6.5 11 36 6 3 12.5 19 35.5 1/4 6.5

Load at the end of lever + m a + K 3 a1 I = m 12 4a + b (Example) When the shape of m is a I = m + m 12 4a1 + b 5 2r sphere, refer to 7 above: w K = m 10. Gear transmission 5. Thin rectangular plate (rectangular parallelopiped) Position of rotational axis: Through the center of gravity and perpendicular to the plate (also the same in case of a thicker Number of teeth = a plate) 1.

Z S 15 M ZX Series Wiring specifications (Vacuum switch) X3 SX3000 ZR Lead wire length 0.6 m Nil L C CL CN Grommet type Lead wire length 3 m Rated voltage ZM Lead wire length 0.6 m DC specifications Connector type Lead wire length 3 m Connector type 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC ZH Output specifications (Vacuum switch) ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South

Slim line coupler not shown 5/8 27/32 1 1 C6 C2-SL C2 C4 C8 C6 C3 C1 C5 C2 1/2 C7 C3 1/2 Reducing Couplings not shown Note not shown not shown 1 1/8 7/16 Dia. 3/8 Dia. Typ. 3/8 Dia. 5/16 Dia. Typ. 1/4 Dia.

(B), 4 (A) Applicable solenoid valve Manifold block size Weight kg Stations 1 (P), 3 (R2) 5 (R1) port size Piping direction Size Rc1/4 Rc3/8 C6 (for 6) C8 (for 8) C10 (for 10) Note) Right, Left Rc1/4 Rc3/8 C12 (for 12) ISO size 1 VQ7-6 ISO size 1 series 0.43n + 0.49 (n: Stations) 10 stations max.