SMC Corporation of America
Elite Part Number Search
Search Results "ISE75G-02-L2-ML"

Please contact us for the latest version.sales@ocaire.com, 40MM ML*, ACTUATOR, ML1 LOCKING BAND CYLINDER, M1, 40MM ML*

Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 24, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net

Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 12, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net

Thomas Liquid Diaphragm Pump Flow Rate: 180 ml / min , 180 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 24, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net

Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net

Thomas Liquid Diaphragm Pump Flow Rate: 150 ml / min , 150 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 5 m H20 , 5 m H20, Voltage (DC): 24, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net

Thomas Liquid Diaphragm Pump Flow Rate: 180 ml / min , 180 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 12, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net

Thomas Liquid Diaphragm Pump Flow Rate: 180 ml / min , 180 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 24, DC Motor Type: Low Cost, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net

Thomas Liquid Diaphragm Pump Flow Rate: 180 ml / min , 180 ml / min, Max Pressure: 30 m H20 , 30 m H20, Max Suction: 6 m H20 , 6 m H20, Voltage (DC): 12, DC Motor Type: Standard, Item Dimensions: Length: 2.05 in / 52 mm Width: .91 in / 23 mm Height: 1.46 in / 37 mm , Length: 2.05 in / 52 mm, Width: .91 in / 23 mm, Height: 1.46 in / 37 mm, Net

Thomas Liquid Peristaltic Pump Flow Rate: 220 ml / min , 220 ml / min, Max Pressure: 8 m H20 , 8 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (DC): 24, DC Motor Type: Low Cost, Net Weight: .44 lbs. / .2 Kg Series Configured Datasheet.

Thomas Liquid Peristaltic Pump Flow Rate: 14 ml / min , 14 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase, Item Dimensions: Length: 3.15 in / 80 mm Width: 3.39 in / 86 mm Height: 3.62 in / 92 mm , Length: 3.15 in / 80 mm, Width: 3.39 in / 86 mm, Height: 3.62

Thomas Liquid Peristaltic Pump Flow Rate: 48 ml / min , 48 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: 1.3 lbs. / .6 Kg Series Configured Datasheet.

Thomas Liquid Peristaltic Pump Flow Rate: 25 ml / min , 25 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 8 m H20 , 8 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: 1.3 lbs. / .6 Kg Series Configured Datasheet.

Flow Rate: 190 ml / min , 190 ml / min, Max Pressure: 40 m H20 , 40 m H20, Max Suction: 3 m H20 , 3 m H20, Voltage (DC): 24, DC Motor Type: BLDC, Net Weight: .29 lbs. / .13 Kg Series Configured Datasheet.

Thomas Liquid Diaphragm Pump Flow Rate: 1000 ml / min , 1000 ml / min, Max Pressure: 10 m H20 , 10 m H20, Max Suction: 4.5 m H20 , 4.5 m H20, Voltage (DC): 24, DC Motor Type: Standard, Net Weight: .75 lbs. / .34 Kg Series Configured Datasheet.

A B L L2 MM R1 R2 U L2 MM L1 NDd9 3 NDH10 3 NX Part no.

13.3 12 13.3 2 x Connection thread Rc1/8 13.3 12 L1 One-touch Connection Screw-in Connection Model L1 L2 ZU05mA 52 25.4 ZU07mA 59 32.4 Model L1 ZU05mA01 67.2 ZU07mA01 74.2 2 These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Load (kg) Note: 1 Nm = 0.7375 ftlb 1 kg = 2.2046 lb 1 in = 25.4 mm W1 W W m Moment (Nm) M = F x L M = F x L M = F x L F3 F2 F1 L2 L1 L3 1. Maximum allowable load (1), static moment (2), and dynamic moment (at the time of impact with stopper) (3) must be examined for the selection calculations.

Load weight (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3 1. Maximum load weight (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

A B L L2 MM R1 R2 U L2 MM L1 NDd9 3 NDH10 3 NX Part no.