Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L2 (w/Control Unit, Supply Port: Left Side, With regulator, Square type pressure gauge, 0.4 MPa)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: None, Made to Order: X731 (Compatible with Argon and Carbon Dioxide
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None]
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None]
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2 [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: None]
(Single Solenoid)], Voltage: 6 (12 VDC), Common Specifications: Positive Common, Connector Entry: C (Dedicated for Centralized Wiring), Light/Surge Voltage Suppressor: Z [with Light/Surge Voltage Suppressor, (Polar Type)], Switch: None, 2A/2B Fitting Port Size: L2 [ø2 One-touch Fitting, Elbow Fitting (Upward Entry), Metric Size], Single Solenoid Wiring Specification: D (Double Wiring)
(Single Solenoid)], Voltage: 12 VDC, Common Specifications: Positive Common, Connector Entry: Dedicated for Centralized Wiring, Light/Surge Voltage Suppressor: Z [with Light/Surge Voltage Suppressor, (Polar Type)], Switch: None, 2A/2B Fitting Port Size: L2 [ø2 One-touch Fitting, Elbow Fitting (Upward Entry), Metric Size], Single Solenoid Wiring Specification: Double Wiring
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: Fixed SI Unit, Stations: 4, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge, 2 Port Solenoid Valve Rated
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: Centralized Lead Wire, Lead Wire Only, Bracket Option: Bracket, Control Unit: w/Control Unit
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit,
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: NPN Output, Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit,
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit,
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Right Angle, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 6, Cable Option: Centralized Lead Wire, Lead Wire Only, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge, 2 Port
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side,
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Straight, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge, 2 Port Solenoid Valve Rated Voltage
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: NPN Output, Unit Specification: Fixed SI Unit, Stations: 2, Cable Option: None, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Right Angle, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge, 2 Port Solenoid Valve Rated Voltage
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Centralized Lead Wired, w/Bracket, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge, 2 Port Solenoid
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: NPN Output, Unit Specification: Fixed SI Unit, Stations: 6, Cable Option: None, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Square embedded type pressure gauge, 2 Port Solenoid Valve Rated Voltage: -