Note 2) Use series CY1B if the stroke exceeds 1500 mm with a tube inside diameter of 20 mm.
B Rotation range m 190 40 10 20 10 1 2 3 7 20.9 22.8 24.4 28.7 16.9 18.8 20.4 24.7 A A 190 35 10 20 10 190 30 10 15 10 When D-F9 is used 190 25 10 15 10 Rotation range m: Value of the operating range Lm of a single auto switch converted to an axial rotation angle.
Outside Inside the controller 10k (a) 1k (a) IN0
Never use in an atmosphere of explosive gases. 6. Do not use in an environment where there is excessive impact shock. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.
Outside Inside the controller 10k (a) 1k (a) IN0
(per stroke) Model Weight (g) Dimensions (per stroke) Model Weight (g) Dimensions (per stroke) Model Weight (g) Lateral A 17 20 B 34 40.5 D 11 14.5 11.0 12.2 A 17 20 B 30 37 D 10 14 7.7 8.6 A 17 20 B 34 40.5 D 11 14.5 11.0 12.2 A 17 20 B 30 37 D 10 14 7.7 8.6 ZP3-Y015U:J3-B3 ZP3-Y015U:J6-B3 ZP3-Y015U:K3-B3 ZP3-Y015U:K6-B3 ZP3-Y02U:J3-B3 ZP3-Y02U:J6-B3 ZP3-Y02U:K3-B3 ZP3-Y02U:K6-B3 Note)
When using as a stopper, select a model with a stroke of 30mm or less for bore sizes 20 and 25, and 50mm or less for bore sizes 32 to 100.
When using as a stopper, select a model with a stroke of 30mm or less for bore sizes 20 and 25, and 50mm or less for bore sizes 32 to 100.
N 1.5 N F A 1.5 F H S + Stroke 20 Non-lock manual release type K (This drawing shows the cases of 20 and 25.)
This information is needed when contacting an SMC sales distributor. (It is an example of model "HRS040-A-20".)
When tightening an auto switch mounting screw, use a watchmakers screwdriver with a grip diameter of 5 to 6 mm.
Switch When tightening an auto switch mounting screw, use a watchmakers screwdriver with a grip diameter of 5 to 6 mm.
Avoid using and storing this product in the following environments since they may cause damage to this product. a) Avoid using in a place that exceeds an ambient temperature range of 0 to 50 C. b) Avoid using in a place that exceeds an ambient humidity range of 35 to 80% Rh. 2.
When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8. Cautions for use in an interlock circuit.
Note) The minimum bending radius of the D-sub connector cable is 20 mm. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 COM 572 VQC Series Plug-in Unit Base Mounted F IP40 compliant VQC1000/2000 Series Kit (D-sub connector) (L4) (L3) L2 L1 VV5QC11 (5.25) 63.5 51 35 28 1.5 P = 10.5 Manual override 13 (12) Indicator light 1.5 SV (5.5) SYJ B A A B A B A B A B A B A 2 93.5
This information is needed when contacting an SMC sales distributor. THERMO CHILLER HRS050-A-20 POWER SUPPLY SERIAL No.
500 600 V(mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 Vertical Transfer 12 50 B B B 20 A 10 A A 40 H W(kg) W(kg) H 8 W(kg) 15 30 6 10 20 4 5 2 10 0 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500 600 0 100
) 11 7.5 MY1C (Cam follower guide type) B A (mm) 16 20 Mounting position A 70 90 B 90 110 Operating range l Note) 11 7.5 MY1H (High precision guide type) B A (mm) 10 16 20 Mounting position A 27 35 20 B 133 165 90 Operating range l Note) 6.5 8.5 11 8-11-102 98 Auto Switch Series MY1 Proper Auto Switch Mounting Position (Detection at stroke end) D-Z7, D-Z80 Note) The operating range is a guide