SMC Corporation of America
Elite Part Number Search
Search Results "CLA2F50-250-D"

ZK2 CH A 2 04 L A KQ2P 06 Applicable stations 02 For 2 stations manifold 04 For 4 stations manifold 06 For 6 stations manifold 08 For 8 stations manifold 10 For 10 stations manifold d Models and Dimensions D Symbol Applicable size d A L D Weight [g] Note 06 6 18 35 8 1 White 08 8 20.5 39 10 2 White 07 1/4" 18 35 8.5 1 Orange 09 5/16" 20.5 39 10 2 Orange Connector type 1 D sub-connector (25

Example) XLA-25H0-2M9NJLA-XAN1A 18 XLm Series Dimensions XLA/F (With D-M9mJm) C E E C E Fn D Heat-resistant auto switch H B A Heater G A [mm] Series Valve size A B C D E Fn G H 25 50 121 48 27 12 40 26 44 40 65 171 66 39 11 55 41 67 50 70 185 79 46 11 75 52 72 XLA XLF XLC/G25, 40 (With D-M9mJm) XLC/G50 (With D-M9mJm) C E C E E C E E C E Fn B A Fn D D Heat-resistant auto switch H J K H B A

Dimensions for Mounting of Auto Switch D-Z7/Z8 (Reed switch) D-Y5, D-Y6, D-Y7 (Solid state switch) A Dimension Bore size (mm) Auto switch model 10 15 20 25 32 6 A D-Y59A/Y7P/Y59B D-Y69A/Y7PV/Y69B D-Y7NWV/Y7PWV/Y7BWV D-Y7NW/Y7PW/Y7BW D-Y7BAL D-Z7, D-Z8 0.2 0.7 6.0 0.7 6.5 1.2 Mounting of Auto Switch When mounting and securing auto switches, they should be inserted into the cylinders switch

/Y7PV D-Y7W/Y7WV D-Y7BA D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BA 5 5 5 5.5 5.5 5 5 5 5.5 5.5 Perpendicular electrical entry type and D-Y7BAL cannot be mounted on 16, 20, 50 and 63.

24.5 37.5 55.5 55.5 30.5 20.5 MXQ20 47.5 37.5 27.5 37.5 43.5 75.5 78.5 81.5 35.5 33.5 65.5 68.5 73.5 37.5 27.5 17.5 27.5 25.5 23 MXQ25 56.5 46.5 36.5 36.5 50.5 64.5 92.5 92.5 50.5 40.5 54.5 82.5 73.5 46.5 36.5 26.5 26.5 40.5 27 Solid State Auto Switch: D-M9BV, D-M9NV, D-M9PV, D-M9BWV, D-M9NWV, D-M9PWV Stroke B Stroke E Model A 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150

For detailed specifications, refer to page 10-20-1. 50 7 63 9 80 9.5 100 10.5 CV D-Z7/Z80 D-A3/A44 D-A3C, D-A44C D-A5/A6 D-B5/B64 D-A59W D-B59W D-Y5/Y6 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-F5/J5 D-F5W/J59W D-F5BAL/F5NTL D-F59F D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL D-G59F D-G39/K39 D-G39C, D-K39C MVGQ Electrical entry (Fetching direction) D-A53/A56 D-A64/A67 D-B64 D-Z80 D-F59/F5P/J59 D-F59W/F5PW/J59W

For detailed specifications, refer to page 10-20-1. 50 7 63 9 80 9.5 100 10.5 CV D-Z7/Z80 D-A3/A44 D-A3C, D-A44C D-A5/A6 D-B5/B64 D-A59W D-B59W D-Y5/Y6 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-F5/J5 D-F5W/J59W D-F5BAL/F5NTL D-F59F D-G5/K59 D-G5W/K59W D-G5NTL/G5BAL D-G59F D-G39/K39 D-G39C, D-K39C MVGQ Electrical entry (Fetching direction) D-A53/A56 D-A64/A67 D-B64 D-Z80 D-F59/F5P/J59 D-F59W/F5PW/J59W

Single round shaft: ClRA1BT Double shaft (round shaft, with four chamfers): ClRA1BJ Double round shaft: ClRA1BK D D D H H H H UU UU M N 0 0.2 G D L 0 0.2 [mm] [mm] [mm] Size D (g6) H Size D (g6) G H M N UU L Size D (g6) H UU 30 8 25 50 15 36 63 17 41 80 20 50 100 25 60 30 8 6 25 10 8 75 7.8 50 15 11 36 20 15 118 14 63 17 13 41 22 17 139 16 80 20 15 50 25 20 167 19 100 25 19 60 30 25 202 24

Recommended tightening torque Unit: Nm Applicable models AMS20 AMS30 AMS40 AMS60 Part No. of spacer with bracket Y200T-2-D Y300T-2-D Y400T-1-D Y600T-2-D Part No. of spacer Y200-D Y300-D Y400-D Y600-D Tightening torque 0.360.036 1.20.05 1.20.05 2.00.1 When the air management system is fixed on a wall with hexagon socket head cap screws, a hexagonal driver is recommended as a tool.

D-859W D-B53, D-A53 0-A64. D-864 surgeabsolber D.A54, D-854, D-A44(C), D-A34(C) D-467 Feed switch D-A33(C) Solid State Type Internal Circuit D-F59, D-G59, D-G39(C) D-FsPW D-GsPW o Lalch typ d agnos s oinput Biue o D-FsP, D-GsP D.FsBAL, D.GsBAL, D-K59W, D-J59W D-F5NTL, D-GsNTL @ D-J59, D-K59, D-K39(C) ffit*' iffil.

Unit: g Model D-M9N D-M9B D-M9P 0.5 8 7 8 Lead wire length m 3 41 38 41 Auto Switch Dimensions Auto Switch Internal Circuit D-M9 M2.5 x 4l mounting hole Slotted set screw Indicator light D-M9B, N, P D-M9N DC(+) Brown 2.6 Main circuit of switch Main circuit of switch Main circuit of switch OUT Black 2.7 2.8 4 22 DC(-) Blue 3.2 D-M9N, P (3-wire) D-M9P Most sensitive position 6 DC(+) Brown 22

D-859W D-B53, D-A53 0-A64. D-864 surgeabsolber D.A54, D-854, D-A44(C), D-A34(C) D-467 Feed switch D-A33(C) Solid State Type Internal Circuit D-F59, D-G59, D-G39(C) D-FsPW D-GsPW o Lalch typ d agnos s oinput Biue o D-FsP, D-GsP D.FsBAL, D.GsBAL, D-K59W, D-J59W D-F5NTL, D-GsNTL @ D-J59, D-K59, D-K39(C) ffit*' iffil.

Note 5) Dimensions other than those marked (LA) are the same as the basic type (no locking type). 598 RS2H Series Auto Switch Mounting 1 Auto Switch Proper Mounting Position (Detection at Stroke End) D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A B Auto switch Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A 9.0 B 23.5 A 11.0

121.5 110.5 95.5 80.5 Operating range Note) Operating range Note) 8 8 8 5.5 5 5 5 5.5 11.5 11.5 12 12 12 Operating range Note) Perpendicular electrical entry is not available for 50 and 63. ( ) D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV MY1CW25/32/40/50/63 B A Reed Switch Solid State Switch D-Z73, D-Z76, D-Z80 (mm) D-Y7BAL (mm) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) D-Y59 , D-Y69 , D-Y7P(

D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV ( ) MY1CW 25, 32, 40, 50, 63 B A Solid state switch D-Y59 , D-Y69 , D-Y7P(V) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) A B A B Reed switch D-Z73, D-Z76, D-Z80 D-Y7BAL 63 50 40 32 25 Mounting position 40 32 25 Mounting position 25 Mounting position 32 40 50 63 A 323.5 278.5 157.5 127.5 97.5 157.5 127.5 97.5 97.5 127.5 157.5 278.5 323.5 A A B 136.5 121.5

D Note) Be sure to use a flat washer for the A type mounting. b) Mounting type B (when using the cylinder tube threads) E t E t REA REB Compatible Mounting Bolt Dimensions Mounting type A Mounting type B REC Model Mounting bolt size E (mm) C (mm) D: Bolt length (mm) Mounting bolt size MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB30-D MQQTB40-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB30

Semi-standard: "-" Standard Port thread Part No. type Rc C2SF-C-D G Rc C2SF-D G NPT C2SF-C(Z)-D NPT C2SF(-Z)-D Appearance and part No. Semi-standard: "6C" Standard Port thread type Part No.

Semi-standard: "-" Standard Port thread Part No. type Rc C2SF-C-D G Rc C2SF-D G NPT C2SF-C(Z)-D NPT C2SF(-Z)-D Appearance and part No. Semi-standard: "6C" Standard Port thread type Part No.

Mounting Position (Detection at Stroke End) and Its Mounting Height D-M9 D-M9W D-M9A D-A9 A 22 [24] (24.5) W B [ ]: Value of the D-M9A ( ): Value of the D-A90/A93 D-M9V D-M9WV D-M9AV D-A9V A 20 (22) W B ( ): Value of the D-M9AV/A9V (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V A 16.5 15.0 22.0 30.0 D-M9A A 16.5 15.0 22.0 30.0 D-M9AV A 16.5 15.0 22.0 30.0 Bore size (mm) 6 10 16 20 B 2.5 7.5