e Valve Model SX340 is for internal pilot.
29 26 6.5 Operating port M5 x 0.8 Y Y 26 103 Operation direction B 5H9 +0.03depth 4.5 0 (Plug : M-5P) Operation direction B A 9 8 10 15 15 10 7.5 19.2 A 35 26.5 20 Z A Cross section AA (scale 50%) 4-M5 x 0.8 thread depth 10 3 x H G Bottom through hole 4.2 H 6 depth 4.5 5H9 +0.03 0 F E 5H9 +0.03depth 4.5 0 Model Z J H G F E MXW12-50 205 84 35 50 88 58 MXW12-75 230 89 40 55 103 63 Note) Adjuster
60 Mounting type E Bore d2 CK S5 K1 K2 l3 G1 l1 G2 EM G3 CA H6 R1 32 11 10 6.6 38 51 10 21 7 18 26 31 32 8 10 40 11 12 6.6 41 54 10 24 9 22 28 35 36 10 11 50 15 12 9 50 65 12 33 11 30 32 45 45 12 12 63 15 16 9 52 67 14 37 11 35 40 50 50 12 15 80 18 16 11 66 86 18 47 12.5 40 50 60 63 14 15 100 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 Mounting type CR Rear clevis with ball joint A B C
32, 40, 50, 63, 80 and 100.) 8-21-18 18 Guide Cylinder Series MGG Construction 20 to 50/MGG #8 !
<> <> ON(SVON ON) Unable to find motor phase in set time. (1-193) E <> ON SVON ON <> Output current limit exceeded E <> set value (1-194) <> Current sensor abnormality has occurred. (1-195) E <> <> Position error overflowed (1-196) E <> <> EEPROM Memory abnormality has occurred (1-197) E <> EEPROM 10 <> CPU CPU CPU error (1-198) E <> -93No.JXC-OMT0001CN-C 14. / A () 50mm
(0-149) D RESET SVON <> <> (0-901) E <> (0-902) E <> <> <> (0-910) E <> SDRAM SDRAM (0-911) E <> 87 No.SFOD-OMT0009CN-B code <> FROM FROM (0-912) E <> <> Modbus (CI 1 2 CI 3 4)OFF <> Modbus (0-913) E <> (0-914) E <> 88 No.SFOD-OMT0009CN-B (2) code <> , [] (1) (2) =0 (3) (4) (5) (6) (7) (1-048) B RESET <> <> [] (1) -+ (2) (1-049) B <> RESET <> + JOG <> + (1-052
for 1/4" (Inch size) N3: With One-touch fitting for 5/32" N7: With One-touch fitting for 1/4" N9: With One-touch fitting for 5/16" SX 000-50-3AP PG PH SX 000-50-4AFor 45(N) (Flat ribbon cable) SX 000-50-5ASX 000-50-6AT T1 For 45 (Terminal block) SX 000-50-7A1-6-110 111 Base Mounted Series SX3000/5000 How to Increase Manifold Bases (1) Loosen bolt (a) fixing the manifold base until it begins
Model H G F L M N E B (E) 2-B 4 6 LQ2T22 LQ2T21 4 6 L 18 19 12 34.5 19.9 1/4 10 LQ2T52 LQ2T51 LQ2T42 LQ2T41 LQ2T33 LQ2T32 LQ2T31 F (M) 43 SMC 5 6 8 24 22 9 18 26.2 52 42.5 (E) (E) G H 12 19 10 12 L L 6 30 28 11 22 33.1 21 59.5 51 Class 2, 3 7 36 32 14 28 40 46 58.5 (M) N Inch sizes Applicable tubing O.D.
3 position 0-1OOPSl (0-7kSf ,/cm,) Operating pressure range 6 g 70 E E 60 2 position single P-100PS| (P-7ksf/cm,) P:Supply pressure 50 Pilot pressure range 2 position double 14-100 (1-7ksllcm?)
3 position 0-1OOPSl (0-7kSf ,/cm,) Operating pressure range 6 g 70 E E 60 2 position single P-100PS| (P-7ksf/cm,) P:Supply pressure 50 Pilot pressure range 2 position double 14-100 (1-7ksllcm?)
override Rated voltage Nil Push type 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz B Locking type (Slotted) C Locking type (Manual) 110 to 120 VAC, 50/60 Hz 4 Surge voltage suppressor Option 220 VAC, 50/60 Hz Indicator light 24 VDC 12 VDC 5 6 Light/Surge voltage suppressor E EZ Nil None 7 240 VAC, 50/60 Hz With light/surge voltage suppressor (Type E, T, D, or Y only) 9 Other Z Option S With
to 500 Up to 600 Up to 600 Up to 800 Up to 800 10 14 18 18 22 26 M14 x 1.5 10.5 M18 x 1.5 M18 x 1.5 12 14 15 11.5 17 M22 x 1.5 M26 x 1.5 With Rod Boot 151 to 200 l 151 to 200 h Bore size (mm) e f 1 to 50 25 25 25 25 25 25 51 to 100 37.5 37.5 37.5 37.5 37.5 37.5 101 to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400 125 125 125 125 125 125 401 to 500 150 150 150 150
to 500 Up to 600 Up to 600 Up to 800 Up to 800 10 14 18 18 22 26 M14 x 1.5 10.5 M18 x 1.5 M18 x 1.5 12 14 15 11.5 17 M22 x 1.5 M26 x 1.5 With Rod Boot 151 to 200 l 151 to 200 h Bore size (mm) e f 1 to 50 25 25 25 25 25 25 51 to 100 37.5 37.5 37.5 37.5 37.5 37.5 101 to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400 125 125 125 125 125 125 401 to 500 150 150 150 150
Model VV3Z2-20 VV3Z2-30 VV3Z2-50 -S50 Part no.
3 position 0-1OOPSl (0-7kSf ,/cm,) Operating pressure range 6 g 70 E E 60 2 position single P-100PS| (P-7ksf/cm,) P:Supply pressure 50 Pilot pressure range 2 position double 14-100 (1-7ksllcm?)
connector LO 110 VAC 50/60Hz 5000mm 50 3 With lead wire M [115 VAC 50/60Hz] M plug connector Without lead wire MN 220 VAC 50/60Hz 4 Without connector MO [230 VAC 50/60Hz] Without connector cable WO M8 connector For type "W", DC voltage is only available.
3 w q e RE A B REC CX CY !5 !0 !1 !2 u y i o MQQ M RHC MK(2) Material Note Component Parts RS Q G No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !
Alarm Sequence Setting range : On, Off Indicated content : Use of temp. upper/lower limit alarm U p p e r / L o w e r T e m p . A l a r m S e q u e n c e M O D E < O f f sequence(Ex. : Off) Function : Determines whether or not temp. upper/lower limit alarm is output when power is turned on.
Example) ZR100-K15MZ-E . 1 ZR1-RV3 . 1 13-3-37 37 Series ZR Valve Unit: ZR1-V Specifications ZR1-V Valve unit part no.