Body Size: 40, Model Type: D (Filter Regulator + Mist Separator), Thread: F (G), Port Size: 04 (1/2), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: G (Round Type Pressure Gauge, w/Limit Indicator), Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator
Body Size: 40, Model Type: D (Filter Regulator + Mist Separator), Thread: F (G), Port Size: 04 (1/2), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: w/o Pressure Gauge, Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator), Bowl Guard: None, Air Filter
Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: DG (D + G), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: D (N.O. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: DG (D + G), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: DG (D + G), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Model Type: B (Air Filter + Regulator), Thread: Rc, Port Size: 04 (1/2), Float Type Auto Drain: D [N.O.
Body Size: 40, Model Type: B (Air Filter + Regulator), Thread: Rc, Port Size: 04 (1/2), Float Type Auto Drain: D [N.O.
Body Size: 40, Model Type: B (Air Filter + Regulator), Thread: Rc, Port Size: 04 (1/2), Float Type Auto Drain: D [N.O.
Body Size: 40, Model Type: D (Filter Regulator + Mist Separator), Thread: Rc, Port Size: 04 (1/2), Float Type Auto Drain: C [N.C.
Body Size: 40, Model Type: Air Filter + Regulator + Lubricator, Thread: N (NPT), Port Size: 04 (1/2), Float Type Auto Drain: D [N.O.
Body Size: 40, Model Type: D (Filter Regulator + Mist Separator), Thread: Rc, Port Size: 04 (1/2), Float Type Auto Drain: w/o Auto Drain, Pressure Gauge/Digital Pressure Switch: G (Round Type Pressure Gauge, w/Limit Indicator), Attachment: V (Mounting Position: AF + AFM + AR + V), Set Pressure: 1 (0.02 to 0.2 MPa Setting), Bowl Type + Lubricator: Standard (Polycarbonate Bowl + Lubricator)
1 I.{ 50 114 139 13 100 10 t 15 5 9 5.5 v 74 4.5 AMG25O 3/8 '152 13 1 1 3 6 10 '| 69 n '12 4 84 a 5 2 n Ai/lc350 1/2 144 16 145 s s '10 198 m 2 14 7 80 100 g 2.3 ANtG450 314 205 19 147 106 106 JO s 10 14 88 1 1 0 3.2 AMG55O 239 200 10 257 100 s 10 't6 102 130 m 10 4.5 AIVG&5O 1 112 291 c 253 r60 160 10 364 150 .10 20 1 1 s 136 180 4.5 2 48 a 348 220 ?
Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 6 8 10 12 Inch sizes 03 05 07 11 13 1/8 3/16 1/4 3/8 1/2 Different diameter tubing order example Basic size With reducer Note) Applicable fitting: LQ2 Different diameter tubing (with plug-in reducer) can be selected within the same body class. (Example) Body class 3 A side: 10 x 8 B side: 8 x 6 Order as shown below.
g 1,100 g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W2/3.
2 VSA4140-04 VSA4140-06 VSA4240-04 VSA4240-06 VSA4340-04 VSA4340-06 VSA4440-04 VSA4440-06 1 8 Rc 2 position single SA 1 2 1.31 1 8 Rc 3 4 1 2 1 8 Rc 2 position double 3 position closed center 1 2 1.50 VA 3 4 1 2 3 4 1 2 3 4 1 8 Rc 1 8 Rc 1 2 1.73 VM 1 8 Rc Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area:
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector)
Size: 1/2, Thread: M Thread, Rc(PT), Port Size: 1/2, Accessory: None, Attachment: Residual Pressure Relief 3 Port Valve, Option 1: -, Option 2: -, Option 3: -
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: C (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None)