SMC Corporation of America
Elite Part Number Search
Search Results "11-LEJS40S2A-200"

1 2 3 4 5 6 7 8 9 10 11 12 13 80 0 5 10 15 20 25 30 35 40 45 50 55 60 Load capacity (N) Load capacity (pounds) 63 300 12.0 280 11.0 Distance from pivot point (inches) 260 Distance from pivot point (mm) 10.0 240 9.0 220 200 8.0 180 7.0 160 6.0 140 5.0 120 100 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 4.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Load capacity (N) Load capacity

D-X 20Data 10-9-11 11 Lever Detection Switch (Proximity Switch) Proximity Switch Specifications/Maker: OMRON Corp. Mounting Position E2E-X1C1 E2E-X2D1-N Model RSH20, 32 RS1H50, 63, 80 Applicable cylinder bore size E2E-X1C1 (For RSH20/32) While holding the lever in the detection range of the switch, screw in the switch gradually until the indicator light (red) turns on.

70 100 200 300 10 30 50 70 100 200 300 Eccentric distance l (mm) Eccentric distance l (mm) Selection graph to 700mm/s Selection Example: Vertical Upward Mounting Solid line: Operating pressure 0.4MPa or more 100 50 Selection conditions Mounting: Vertical upward (lifter) Maximum speed: 500mm/s Load mass: 40kg Eccentric distance: 80mm Load mass m (kg) Refer to graph based on vertical mounting

D-X 20Data 10-9-11 11 Lever Detection Switch (Proximity Switch) Proximity Switch Specifications/Maker: OMRON Corp. Mounting Position E2E-X1C1 E2E-X2D1-N Model RSH20, 32 RS1H50, 63, 80 Applicable cylinder bore size E2E-X1C1 (For RSH20/32) While holding the lever in the detection range of the switch, screw in the switch gradually until the indicator light (red) turns on.

AD17, 27-A I.D. f2.5 (f3/32") at min., Length 5m (200") at max. AD37, 47(N)-A I.D. f4 (f3/16") at min., Length 5m (200") at max. AD38, 48(N)-A I.D. f6.5 (f1/4") at min., Length 5m (200") at max. CAUTION Lubricator Avoid rising piping and piping branches on secondary side. Otherwise, lubricating failure may be caused. Air Source WARNING Air combination Use clean air.

(mm) Symbol 1 2 3 Note 2) Port size Rc 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 1 2 3 Note 1) 4 Symbol Nil: Non-locking push type N.C. 1 MPa N.C. 0.5 MPa N.O. 1 MPa C.O. 1 MPa Note) 4 Note 2) A: Non-locking push type A (projecting) 1 6A 8A 10A 1 8 1 4 3 8 5 6 Note 2) 7 Valve size 1 to 4 7 Note 2) 11 15 11 10A 3 8 B: Slotted locking

W X Y ZZ J 32 34 27 1/8 154 6.5 7 30 198 3.2 32 57 50 6 M10 x 1.25 37 47 13 6.5 22 9 232 M6 x 1.0 40 39.5 27 1/4 161 8 9 33 209 3.2 38 64.5 55 6 M14 x 1.5 41.5 51 16.5 9 24 11 247 M6 x 1.0 50 47 31.5 1/4 183 9 9 40 237 3.2 46 77.5 70 7 M18 x 1.5 47.5 58 20 10.5 27 11 279 M8 x 1.25 63 55.5 31.5 3/8 197 8.5 12 48 251 3.6 56 93 80 7 M18 x 1.5 55 58 23 12 27 14 296 M8 x 1.25 80 61.5 38 3/8 245

MSM011P1A MSM012P1A 100 100/115 200/230 100/115 200/230 100/115 200/230 MSD011P1E MSD013P1E MR-C10A1 MR-C10A SGDE-01BP SGDE-01AP Matsushita Electric Industrial Co., Ltd. For a non-standard motor specification, when the motor is mounted before shipping, the driver is included but the cable that connects the motor and driver is optional. Refer to page 178 for part numbers.

H A 30 ZPNA-M22 34.6 Bolts Dimensions (mm) A 11 d M3 x 0.5 12 7 M4 x 0.7 B 5.5 L 8 8 10 15 8.5 M5 x 0.8 13-11-82

Description Qty. 4 4 4 4 1 1 1 1 Seal Seal Seal Seal 10 10 10 10 1 1 1 1 Gasket Gasket Gasket Gasket Parts included in seal kit 11 11 11 11 1 1 1 1 Gasket Gasket Gasket Gasket 15 Wear ring 15 Wear ring 15 Wear ring 15 Wear ring 4 4 4 4 16 Piston seal 16 Piston seal 16 Piston seal 16 Piston seal 4 4 4 4 25 Seal washer 25 Seal washer 25 Seal washer 25 Seal washer 2 2 2 2 A set includes all

SL5201 0.5 to 10 psig (0.0034 to 0.07 MPa) SL5202 0.5 to 30 psig (0.0034 to 0.2 MPa) SL5206 1 to 60 psig (0.007 to 0.4 MPa) SL5210 1 to 100 psig (0.007 to 0.7 MPa) 100 mm Hg absolute to 10 psig (-88kPa to 0.07 MPa) Select compatible materials of construction for the gas Vacuum to 150 psig (1.0 MPa) 500 psig (3.4 MPa) 1000 psig (6.9 MPa) 40 to 160C (40 to 71C) (No freezing) 1) 0.07 2 x 10-11

6-K (6 places) 73 146 6 Series MGF Dimensions 100 MGF100 Scale: 35% 4-M12 x 1.75 through 170 200 160 11.5 53.5 + Stroke 10 65 + Stroke 20 9 2-Rc 1/4 port for extending cylinder When the cylinder is extended Breathing hole for guide (with element) 46 Port for retracting cylinder 4-M12 x 1.75 through M6: T-slot for hexagon bolt K 70 4 170 200 190 11 6-K (6 places) 93 186 7 Solid State Switch

Mounting bolt C D Mounting Bolt Size for NCDQ8B056 to 250(With Auto Switch) (Inch) Model C D Bolt size Model C D Bolt size NCDQ8B056-025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCDQ8B075-025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCDQ8B106-025 037 050 062 075 087 100 125 150 175 200 250 300 350 400 NCDQ8B150-025 037 050 062 075 087 100 125 150 175 200 250

VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) Set temp. range 5 to 35C Set temp. range 5 to 35C Set temp. range 5 to 35C Temp. stability 0.1C Temp. stability

800 800 Mey L5 [mm] L5 [mm] L5 [mm] 600 600 600 m Wall L5 Y 400 400 400 200 200 200 0 0 0 0 10 20 30 40 50 0 10 20 30 40 50 60 70 0 5 10 15 20 25 30 35 Work load [kg] Work load [kg] Work load [kg] 1000 1000 1000 800 800 800 L6 L6 [mm] L6 [mm] L6 [mm] 600 600 600 Z 400 400 400 200 200 200 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 35 0 10 20 30 40 50 60 70 Work load [kg] Work load [kg] Work

V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 97 Thermo-chiller Standard Type HRS100/150 Series Circulating Fluid Temperature Controller Circulating Fluid/Facility Water Line Equipment Circulating Fluid Line Power

Stroke F(N) F(N) 9 15 105 110 115 14 120 125 130 8 13 140 150 175 7 12 5 200 11 Number of auto switches mounted Rotation Linear motion 2 0 0 1 0S 02 S0 S2 SS 1 20 n0 2 2S nS n2 n Combinations of made to order products No.1 to 4 are available. Consult SMC for further information. 1.5-19

A: Non-locking extended type 4 Valve size 1 to 4 6A 8A 10A 1 8 1 4 3 8 5 6 24 VDC 12 VDC 1 7 B: Locking slotted type 7 240 VAC 50/60 Hz 9 Other 11 15 11 10A 3 8 Option 2 15A 1 2 15 14 3 20 16 Nil: Non-locking push type 20A 3 4 Valve size 5 to 7 25 4 25A 1 22 11 4 32A 5 32 Electrical entry/ With light/surge voltage suppressor 1 B 22 32 28 40 6 28 40 1 4 32F Flange 11 2 40A GS Grommet

Heavy load Standard load Midium load Light load 1 10 50 100 1 0.25 0.49 0.98 1.96 2 20 75 200 2 0.49 0.74 1.47 2.94 3 30 100 300 3 0.74 0.98 1.96 3.92 4 40 125 400 4 0.98 1.23 2.45 4.90 5 50 150 500 5 1.23 1.47 2.94 5.88 6 75 200 600 6 1.47 1.96 3.92 7.84 7 100 250 700 7 1.72 2.45 4.90 9.80 8 300 300 800 8 1.96 2.94 5.88 11.76 9 500 500 900 9 2.21 3.92 7.84 15.68 10 1000 1000 1000 10 2.45

H4 S y m b o l Initial power / Power 100 VAC 200/40 200/50 200 VAC 800/40 800/50 consumption (W) Heater assembly number XLA25-60S-1 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. H5 Initial power / Power 100 VAC 200/40 400/70 400/80 200 VAC 800/40 1600/80 1600/80 consumption (W) Note 1) Initial power and power consumption are nominal values.