SMC Corporation of America
Elite Part Number Search
Search Results "RZQL63TN-100-60-M9PWSAPC3"

Thomas Oil-less WOB-L Piston Compressor / Vacuum Pump Flow Rate: 2 CFM / 57 LPM , 2 CFM / 57 LPM, Max Pressure: 100 PSIG / 6.9 bar , 100 PSIG / 6.9 bar, Max Vacuum: 26.9 in HgV / -912 mbar , 26.9 in HgV / -912 mbar, RPM (60 Hz): 1371, Voltage (50 Hz): 230, Frequency (Hz): 50, Phase: 1-phase Series Configured Datasheet.

V or less 100 V IC circuit no Yes Relay, PLC 24 V 2-wire Reed switch Grommet 161

10%, 50/60 Hz10 A5.5 A (100 VAC) to 2.5 A (240 VAC)Refer to alarm function.RS-232CApprox. 28.7 lbs (13 kg)Power cable, Foot for fixing, Splashproof coverCE marking, UL (NRTL) standards, SEMI

PSI (7kgf/cm,) 150 PSI (9.gkglicm,) 40 140"F (5 -60"C) Nose mount, Flange mount, Foot mount, Clevis mount, Trunnion mount Series NCJP BrackeklPartNo.

Both Ends Actuation D Double Acting S Spring Heturn T Spring Extend 9/t6" 056 3t4" 075 1-1l16' 106 t-1/2' 150 2" 200 2-1n' 250 3' 300 4" 400 o12 025 037 050 062 075 087 100 Solid State Switch Sboke 125 150 I -t,14" 1/8. 1t4" 3/8' 1f2" 5/8' 94" 1-1f2" I /4' 200 2-1n" 300 350 400 3-1t2" 4' The siandard lead wire length is 0-5m. 'L' is add6d lor 3m. long lead wire.

The dither may generate vibrations in fe valve which produces a growling noise and may be ad.iusted within a range of 100 to 2m Hz by luming the DITHER adiustment screw.

AC DC Auto switch model Lead wire length (m) 0.5 (Nil) Load voltage Indicator light Wiring (Output) Special function Type Electrical entry Pre-wire connector Applicable load 3 (L) 5 (Z) Perpendicular In-line IC circuit 3-wire A96V A96 5 V Reed switch Solid state switch Grommet (NPN equivalent) Yes Yes 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV

DL08-01 18 32 19 8 14 DL08-02 16 21 38 14 12 24.5 DL08-03 22 54 26.5 31 10 17 DL10-02 23 51 Connection thread 26.5 14 DL10-03 17 22 57 DL10-04 27 28.5 100 DL12-02 25 76 17 43 12 19 28.5 DL12-03 17 26 85 DL12-04 27 17 Union Tee: DT H1 (width across flats) H2 (width across flats) Applicable tubing O.D.

AC (50/60 Hz) Bracket CE-compliant 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] Nil : Without bracket F : With bracket 3 port For type W, only DC voltage is available. Note) CE-compliant: For DC only. Actuation type Bracket 1 2 Normally closed Normally open Bracket is mounted. Brackets cannot be retrofitted. External pilot type is not available.

(Example) 10-SYJ3120-5M-M3 VJ3000-13-1 DC AC (50/60 Hz) CE-compliant CE-compliant 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type W, only DC voltage is available. Note) CE-compliant: For DC only.

70 80 Flow Rate (slpm, N2) A Connections AP501A Input pressure : 2 psig (14 kPa) inch (mm) FV4 MV4 TW4 760 0 2.78 (70.6) 700 -8 2.12 (53.8) Delivery pressure (mmHg abs) Derivery pressure (kPa) 600 -21 500 -35 400 -48 300 -61 200 -75 100 -88 0 -101 0 1 2 3 4 5 6 7 8 Flow rate (slpm, N2) Hastelloy is a registered trademark of Haynes International.

Note 8) For details about wiring, refer to the Operation Manual that can be downloaded from SMC website (http://www.smcworld.com). 1.0 Operating pressure [MPa] PF2D 504/520 0.5 PF2D 540 Made to Order 20 40 60 80 100 0 90 LQ1 series fluoropolymer fittings mounting type is also available. Refer to page 392. Fluid temperature [C] 382 A

Compatible Driver -@ type -# type Driver type Series LECYM LECYU Applicable network MECHATROLINK2 MECHATROLINK-3 Control encoder Absolute 20-bit encoder Communication device USB communication, RS-422 communication Power supply voltage [V] 200 to 230 VAC (50/60 Hz) Reference page Page 766 672

IP8000 IP8100 Type Item Lever type lever feedback Rotary type cam feedback Single action Double action Single action Double action 4 to 20mADC Note 1) Input current Input resistance Supply air pressure Standard stroke Sensitivity Linearity Hysteresis Repeatability Coefficient of temperature 23515 (4 to 20mADC) 0.14 to 0.7MPa 10 to 85mm (Deflection angle 10 to 30) 60 to 100 Note 2) Within

How to Order 100 IP200 Applicable stroke 25 to 300 mm * Manufacture of strokes in 1 mm increments is possible. Specications (No load) Note 1) Replacement Parts Supply pressure 0.3 to 0.7 MPa Input pressure 0.02 to 0.1 MPa Part no.

or less (at 12 VDC) Analog output 1 to 5 VDC (Within rated differential pressure range) Output impedance: Approx. 1 k Output specification 1% F.S. or less 0.5% F.S. or less 0.3% F.S. or less Orange light is on (When energized) IP40 Operating: 0 to 50C, Stored: 20 to 70C (No freezing or condensation) Operating/Stored: 35 to 85% RH (No condensation) 1000 VAC or more, 50/60 Hz for 1 minute

Rated voltage For DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted For AC (50/60 Hz) 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] Electrical entry 24 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VAC Grommet L plug connector M plug connector Indicator light and surge voltage suppressor G: 300 mm lead wire L: With 300 mm lead wire M: With 300 mm lead wire

1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] + -+ LN, MN type: With 2 sockets per valve Refer to page 5 for the lead wire length of L and M plug connectors.

10%, 50/60 Hz10 A3.5 A (100 VAC) to 1.5 A (240 VAC)Refer to alarm function.RS-232CApprox. 26.5 lbs (12 kg)Power cable, Foot for fixing, Splashproof coverCE marking, UL (NRTL) standards, SEMI

Application Remarks Receptacle plug XGT0402-9-12S (For XGT31-50336-C) C016 30D006 100 12 (AMP) 11 - 6Maintenance Please refer to valve maintenance procedure in the attached documents. 7Troubleshooting Condition Assumed cause Countermeasure Gate Internal leakage Operating pressure is low Pressure should be 0.45MPa or more.