Please contact us for the latest version.sales@ocaire.com, MAIN LINE FILTER, AIRLINE EQUIPMENT, AFF MAIN LINE FILTER, GD, AFF 3/4INCH STANDARD (NPT), 3.08647 lb, ModelRated flow Note)(l/min (ANR))Port sizeMass (kg)AFF11C22001 2, 3 41 2, 3 41.4

Please contact us for the latest version.sales@ocaire.com, MAIN LINE FILTER, AIRLINE EQUIPMENT, AFF MAIN LINE FILTER, GD, AFF 3/4INCH STANDARD (NPT), 2.55736 lb, ModelRated flow Note)(l/min (ANR))Port sizeMass (kg)AFF11C22001 2, 3 41 2, 3 41.4

AF , Thickness reduction of resin case provides increased capacity (approx. 1.3 times more). , Improved water separation efficiency extends the service life of filter elements , Rc, NPT or G(PF) type threads, MAIN LINE FILTER, AIRLINE EQUIPMENT, AFF MAIN LINE FILTER, CD, AFF 1/8INCH STANDARD (NPT), .93181 lb, ModelRated flow Note)(l/min (ANR))Port sizeMass (kg)AFF2C3001 8, 1 41

AF , Thickness reduction of resin case provides increased capacity (approx. 1.3 times more). , Improved water separation efficiency extends the service life of filter elements , Rc, NPT or G(PF) type threads, MAIN LINE FILTER, AIRLINE EQUIPMENT, AFF MAIN LINE FILTER, CD, AFF 1/8INCH STANDARD (NPT), .93181 lb, ModelRated flow Note)(l/min (ANR))Port sizeMass (kg)AFF2C3001 8, 1 41

AF , Thickness reduction of resin case provides increased capacity (approx. 1.3 times more). , Improved water separation efficiency extends the service life of filter elements , Rc, NPT or G(PF) type threads, MAIN LINE FILTER, AIRLINE EQUIPMENT, AFF MAIN LINE FILTER, DD, AFF 1/4INCH STANDARD (NPT), .93181 lb, ModelRated flow Note)(l/min (ANR))Port sizeMass (kg)AFF2C3001 8, 1 41

AF , Thickness reduction of resin case provides increased capacity (approx. 1.3 times more). , Improved water separation efficiency extends the service life of filter elements , Rc, NPT or G(PF) type threads, MAIN LINE FILTER, AIRLINE EQUIPMENT, AFF MAIN LINE FILTER, DD, AFF 1/4INCH STANDARD (NPT), .93181 lb, ModelRated flow Note)(l/min (ANR))Port sizeMass (kg)AFF2C3001 8, 1 41

Please contact us for the latest version.sales@ocaire.com, REGULATOR, MODULAR, AIRLINE EQUIPMENT, AR MASS PRO, GA, AR MASS PRO 3/4 MODULAR (PT), 1.57740 lb, ModelPort sizePressure gauge port size Note 1)FluidAmbient and fluid temperature Note 3)Proof pressureMaximum operating pressureSet pressure rangeRelief pressure Note 4)ConstructionMass (kg)AR40(K)-063/41/4Air?

15, 4 connection methods, Maximum operating pressure: 0.8MPa, REGULATOR, MFLD W/GAUGES, AIRLINE EQUIPMENT, ARM MANIFOLD REGULATOR, CB, ARM 1/8INCH STANDARD (PT), .86346 lb, ModelPipingPort sizeMass (g) IN sideOUT sideTotal mass (n: stations)Regulator (Except manifold)ARM2000Common IN1/41/8(188 x n) + 43136

other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket and pressure gauge, MFLD BLOCK, AIRLINE EQUIPMENT, ARM MANIFOLD REGULATOR, D1, ARM 1/4INCH PART, .98767 lb, ModelPipingPort sizePressure gauge port sizeMass (kg) IN sideOUT sideRegulatorEnd plate BodyEnd plateARM2500Common IN--3/81/41

Nil N F Port size Body size 4 Port size 3 Symbol 2 02 03 04 06 1/4 3/8 1/2 3/4 Models AMP220 AMP320 AMP420 Model Max. flow capacity l/min (ANR)(SCFM) 1000 (35) 200 (7) 500 (17.5) 1/2, 3/4 1/4, 3/8 3/8, 1/2 Port size (nominal size B) 1.15 (2.54) 0.43 (0.95) 0.68 (1.50) Weight kg (lb) Specifications Fluid Compressed air Element upstream pressure 0.1MPa or less (14.5 psi or less) 5 to 50C (41

P) (R)3 3(R) 1 (P) SS5YJA3 Fill the same as SS5YJ3 (Refer to page 166.) 3 position closed center 3 position closed center 4(A) (B)2 4(A) (B)2 Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. 5(R) 1 (P) (R)3 3(R) 1 (P) 3 position exhaust center 3 position exhaust center 4(A) (B)2 4(A) (B)2 (Example) SS5YJA3-41

For sub-plate type, manifold type 41, S41, 42, S42, 42R, S42R (With gasket and screws) Body option Nil: Individual pilot exhaust type Electrical entry Manual override 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC Nil: Non-locking push type Grommet L plug connector M plug connector M8 connector R port P, E port G: Lead wire length 300 mm L: With lead wire (Length 300 mm) M

Bore size 20, 25 32, 40 50, 63 80, 100 Stroke range 16 to 49 21 to 99 31 to 99 41 to 99 CU Allowable kinetic energy Stroke range CQS Refer to "Selection" on page 789 regarding the allowable kinetic energy. CQ2 Part no.: RQB32-47 A special tube is manufactured for a 47mm stroke.

The series is available in six size options with a wide range of accessories.2 different body sizes, Variety of different drain options, Aluminum die cast body, MAIN LINE FILTER, AIRLINE EQUIPMENT, AFF MAIN LINE FILTER, GB, AFF 3/4INCH STANDARD (PT), 3.14429 lb, ModelRated flow Note)(l/min (ANR))Port sizeMass (kg)AFF11C22001 2, 3 41 2, 3 41.4

preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket and pressure gauge, REGULATOR, MFLD, AIRLINE EQUIPMENT, ARM MANIFOLD REGULATOR, DB, ARM 1/4INCH STANDARD (PT), 3.03759 lb, ModelPipingPort sizePressure gauge port sizeMass (kg) IN sideOUT sideRegulatorEnd plate BodyEnd plateARM2500Common IN--3/81/41

other SMC air preparation equipment.Internal pilot relieving style (pilot air is always bleeding), Port sizes ranging from 1/4 to 2, Optional bracket and pressure gauge, MFLD BLOCK, AIRLINE EQUIPMENT, ARM MANIFOLD REGULATOR, D1, ARM 1/4INCH PART, .66755 lb, ModelPipingPort sizePressure gauge port sizeMass (kg) IN sideOUT sideRegulatorEnd plate BodyEnd plateARM2500Common IN--3/81/41

formation.Manifold type: stacking, P (IN), A (OUT) type: Common IN/Individual OUT, Valve stations: 2 to 5, Tubing size (port P): 3/8, 1/2., 3/4, Tubing size (port A): 1/4, 3/8, 1/2, 3/4, FLUOROPOLYMER, MFLD BASE, VALVE, FLUOROPOLYMER, 5.43400 lb, ModelManifold typeP (IN), A (OUT) typeValve stationsTubing size (port P)Tubing size (port A)LLC4AStacking typeCommon IN/Individual OUT2 to 5 stations3/41

formation.Manifold type: stacking, P (IN), A (OUT) type: Common IN/Individual OUT, Valve stations: 2 to 5, Tubing size (port P): 3/8, 1/2., 3/4, Tubing size (port A): 1/4, 3/8, 1/2, 3/4, FLUOROPOLYMER, MFLD BASE, VALVE, FLUOROPOLYMER, 4.98300 lb, ModelManifold typeP (IN), A (OUT) typeValve stationsTubing size (port P)Tubing size (port A)LLC4AStacking typeCommon IN/Individual OUT2 to 5 stations3/41

formation.Manifold type: stacking, P (IN), A (OUT) type: Common IN/Individual OUT, Valve stations: 2 to 5, Tubing size (port P): 3/8, 1/2., 3/4, Tubing size (port A): 1/4, 3/8, 1/2, 3/4, FLUOROPOLYMER, MFLD BASE, VALVE, FLUOROPOLYMER, 5.50000 lb, ModelManifold typeP (IN), A (OUT) typeValve stationsTubing size (port P)Tubing size (port A)LLC4AStacking typeCommon IN/Individual OUT2 to 5 stations3/41