SMC Corporation of America
Elite Part Number Search
Search Results "AS3201FG-03-06-J"

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor, -100 to 100, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting)

Size: 200 (1/8 Standard), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 06 (ø6)

Size: 205 (1/4 Standard), Control Range: FSC (50 to 150 mm/s), Indicator Window Direction: 1 (180°), Tube Size: 06 (ø6)

Size: 205 (1/4 Standard), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 06 (ø6)

Size: 205 (1/4 Standard), Control Range: FSC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 06 (ø6)

Specifications: Q (Brass + Electroless Nickel Plating), Model: R (Reducer), Applicable Tube OD: 04 (4mm), Port Size Applicable Tube: 06 (Different Dia. Ø6)

Body, Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: N (For Pressure Switch for Vacuum: None; Pressure Sensor Assembly: None), Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)]

Body, Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 06 [ø6 One-touch Fitting