Series AF modular style air filter is a cost effective, clean looking solution to your filtration needs. Its' modular design allows connection with other SMC air preparation equipment. The series is available in six size options with a wide range of accessories.Modular air filter , Prevents contamination , Lighter weight than old style modular AF , Thickness reduction of resin case provides

Body Size: 50, Thread Type: Rc, Port Size: 06 (3/4), Mounting: w/o Mounting Option, Float Type Auto Drain: w/o Auto Drain, Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: L (w/Element Service Indicator), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI

MIST SEPARATOR. O44. 1.23000 lb. MIST SEPARATOR.

Size: 50, Thread Type: Rc, Port Size: 06 (3/4), Mounting: w/o Mounting Option, Float Type Auto Drain: w/o Auto Drain, Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: L (w/Element Service Indicator), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25

PVC piping type, Applicable fluid:  deionized water, chemical, etc., Flow rate range:  10 to 100 L/min, Integrated type 3-COLOR DIGITAL FLOW SWITCH FOR WATER. F19. 313.00000 lb. DIGITAL FLOW SWITCH, WATER, PF3W.

(w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Size: 40, Thread Type: Rc, Port Size: 04 (1/2), Mounting: w/o Mounting Option, Float Type Auto Drain: w/o Auto Drain, Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: L (w/Element Service Indicator), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units

Size: 40, Thread Type: Rc, Port Size: 04 (1/2), Mounting: B (w/Bracket), Float Type Auto Drain: w/o Auto Drain, Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: L (w/Element Service Indicator), Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa

Auto Drain The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Circulating water Caution Unit [S/cm] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] [mg/L] Item pH (at 25C ) Electrical conductivity (25C ) Chloride ion (Cl) Sulfuric acid ion (SO42) Standard value

l X 140 l M6 X 45 l X 50 l X 55 l X 60 l X 65 l X 70 l X 75 l X 80 l X 85 l X 120 l X 145 l M8 X 50 l X 55 l X 60 l X 65 l X 70 l X 75 l X 80 l X 85 l X 90 l X 125 l X 150 l M10 X 55 l X 60 l X 65 l X 70 l X 75 l X 80 l X 85 l X 90 l X 95 l X 130 l X 155 l M10 X 65 l X 70 l X 75 l X 80 l X 85 l X 90 l X 95 l X 100 l X 105 l X 140 l X 165 l M3 X 25 l X 30 l X 35 l X 40 l X 45 l X 50 l M3

(Except 50) MY1MW16/20/50/63 MY1CW16/20/50/63 L L L L L L R R R R R R R L L R R R L L L R Slide table operating direction MY1MW25/32/40 MY1CW25/32/40 L L This port is not available for use. (Except 32, 40) L L L L L L L L R R R R R R R R L L R R L L L R Slide table operating direction 8-12-3 4 Series MY1W Specific Product Precautions 2 Be sure to read before handling.

(mm) Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Note) Distance to the gripping point L of single acting type is shortened by spring return.

ISA2 52.5 l/min 2.5 l/min IS 10 l/min 100 l/min PF2A511 105 l/min 5 l/min ZSM 20 l/min 200 l/min 210 l/min 10 l/min PF2 PF2A521 IF 50 l/min 500 l/min 525 l/min 25 l/min PF2A551 Data Sensor Flow rate range 0.5 l/min 2 l/min 5 l/min 10 l/min 20 l/min 40 l/min 100 l/min 0.5 l/min 4 l/min PF2W504 PF2W504T 0.35 l/min 4.5 l/min 16 l/min 2 l/min PF2W520 PF2W520T 1.7 l/min 17l/

All dimensions in mittimeiers. 26 I Non-Adjustable Hydraulic Series lmperial Accessories sroP BAR (SB) ['l E -T I c __l _ l F --->l nr tdl o&| (n.ll A I ( D T I Boh Sire W.hhi r5&706300 Pll500 5odo5 l s t T 2 i t I 1 . 6 3 l . l l I l l I l l 6 r r f f r l k " D s ? l y t . I 6 . 1 158650300 PM?