Part Number Description: 10 METER FLAT CABLE Product Line: V Product Line Description: VALVE Family Code: 211 Family Description: VQ1000 SOL VALVE 4/5 PORT Class Code: 21 Part Code: 2 Reference Code: J PDF Documentation: PDF Click here to report information errorImage shown may not match exact part number
Special Application: 10-AF (Clean Series), Body Size: 40, Thread: N (NPT), Port Size: 06 [3/4 (Size 40, 50)], Bracket: None, Bowl Type: 8 [Metal w/Level Gauge (Size 30 to 60)], Option: JZ [J+Nameplate/Caution Plate for Bowl in Imperial Units (Size 20 to 60)]
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: 8J (8 + J), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Series: NCA1 (Standard), Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 1000 (10"), Air Cushion / Rod Boot: J (Nylon Boot & Both Ends Air Cushion)
Body Size: 60, Back Flow: w/o Backflow, Thread: N (NPT), Port Size: 10 (1), Options: B (w/Bracket), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: J (Body Size 20: 1/8; Body Size 30 & 40: 1/4), Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi,
Body Size: 50, Thread: N (NPT), Port Size: 10 (1), Option: B (Bracket), Semi-Standard 1: 8J (8 + J), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 3 (1/8 Basis), Port Size: N01 [Cylinder Side (NPT 1/8) Pilot Port (10-32UNF)], Applicable Tube OD: 07 (Ø1/4"), Lock Nut: J (Round)
Body Size: 40, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 04 (1/2), Option: B (Bracket), Semi-Standard 1: 6J (6 + J), Semi-Standard 2: Standard
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: J (N.C. / None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port
), Bracket: w/o Option, Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
Size: 6, Motor Size: Standard, Lead Screw Type, mm: J (LEPS6: 8; LEPS10: 10), Stroke: 25mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: None, Actuator Cable Length, m: No Cable, Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: No Cable, Controller Mounting: 7 (Screw Mounting)
Table Accuracy: Basic, Size: 10, Max.
Size: 6, Motor Size: Standard, Lead Screw Type, mm: J (LEPS6: 8; LEPS10: 10), Stroke: 25mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: S (Standard Cable), Actuator Cable Length, m: 3, Controller Type - LEC, JXC: CP1 (JXCP1, PROFINET), I/O Cable Length for LEC: No Cable, Controller Mounting: 7 (Screw Mounting)
V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
Supply: w/o Option, Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
Table Accuracy: H (High Precision Type), Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.22; LER30: 0.8; LER50: 6.6), Motor Cable Entry: Basic Type, Entry on Right Side, Actuator Cable Type: R (Robotic Cable, Flexible Cable), Actuator Cable Length: C (20m), Controller Type - JXC: C51 (JXC51, Step Data Input Type, Parallel NPN), Controller Mounting: 8 (DIN Rail Mounting)
: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
Special Application: 10-AF (Clean Series), Body Size: 40, Thread: N (NPT), Port Size: 04 [1/2 (Size 40)], Bracket: None, Bowl Type: 8 [Metal w/Level Gauge (Size 30 to 60)], Option: JZ [J+Nameplate/Caution Plate for Bowl in Imperial Units (Size 20 to 60)]