Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate:
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to
Terminal 1/2, Non Plug-in Standard 1/2)
Function: 2 (2 Position Double), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: B (Bottom Ported), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread:
1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in
/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/2 (15A)15VXZ2242-04--0.70.623.00.346.01.5850
ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/2 (15A)15VXZ2240-04--1.00.723.00.346.01.5760
Certificate: None, Series: Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min
: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min